2.Study on formulation and revision of detection methods of "Standards for indoor air quality (GB/T 18883-2022)" in China.
Hai Jing ZHANG ; Yi Fu LU ; Qin WANG ; Yan Wei YANG ; Yun Pu LI ; Yun Yun WU ; Cheng DING ; Jun Rui CHANG ; Ying ZHU ; Dong Qun XU
Chinese Journal of Preventive Medicine 2023;57(11):1777-1781
The formulation and revision of the detection methods of indoor air quality standards is an important, rigorous and delicate endeavor. This paper introduced the formulation and revision of the detection methods of the standards for indoor air quality (GB/T 18883-2022), focusing on the revision process, revision principles, main adjustments and technical points of some key indicators to facilitate users to better understand and apply the detection methods in standards for indoor air quality (GB/T 18883-2022).
Humans
;
Air Pollution, Indoor
;
China
;
Reference Standards
;
Air Pollutants/analysis*
3.Study on formulation and revision of detection methods of "Standards for indoor air quality (GB/T 18883-2022)" in China.
Hai Jing ZHANG ; Yi Fu LU ; Qin WANG ; Yan Wei YANG ; Yun Pu LI ; Yun Yun WU ; Cheng DING ; Jun Rui CHANG ; Ying ZHU ; Dong Qun XU
Chinese Journal of Preventive Medicine 2023;57(11):1777-1781
The formulation and revision of the detection methods of indoor air quality standards is an important, rigorous and delicate endeavor. This paper introduced the formulation and revision of the detection methods of the standards for indoor air quality (GB/T 18883-2022), focusing on the revision process, revision principles, main adjustments and technical points of some key indicators to facilitate users to better understand and apply the detection methods in standards for indoor air quality (GB/T 18883-2022).
Humans
;
Air Pollution, Indoor
;
China
;
Reference Standards
;
Air Pollutants/analysis*
4.Study on formulation and revision of standard limit for formaldehyde in the "Standards for indoor air quality(GB/T 18883-2022)" in China.
Xiao Yan DONG ; Jiao WANG ; Xian Liang WANG ; Tian Tian LI ; Qin WANG ; Dong Qun XU
Chinese Journal of Preventive Medicine 2023;57(11):1748-1751
Formaldehyde, as an important pollutant in indoor air, has always been of great concern. In the newly issued "Standards for indoor air quality (GB/T 18883-2022)", the standard limit of formaldehyde has been restricted to 0.08 mg/m3. In order to better promote the implementation and application of this new standard, this study reviewed and interpreted the relevant technical content for determining the standard limit, including the indoor concentration and human exposure levels of formaldehyde, the health effects of formaldehyde, and the derivation of safety reference values. It also proposed prospect for the future development and revision of quality standards for formaldehyde in indoor air.
Humans
;
Air Pollution, Indoor
;
Air Pollutants/analysis*
;
Formaldehyde/analysis*
;
China
;
Environmental Pollutants
5.Study on revision of standard limits for benzene in"Standards for indoor air quality(GB/T 18883-2022)"in China.
Guo Min CHEN ; Tian Tian LI ; Yan Jun DU ; Shuai JIANG ; Dao Kui FANG ; Xiao Heng LI ; Ning LIU ; Shu Yuan YU
Chinese Journal of Preventive Medicine 2023;57(11):1752-1755
Benzene, as a major indoor pollutant, has received widespread attention. In order to better control indoor benzene pollution and protect people's health, the limit value of benzene in the"Standards for indoor air quality (GB/T 18883-2022)'' was reduced from 0.11 mg/m3 to 0.03 mg/m3. This study reviewed and discussed the relevant technical contents of the determination of benzene limit value, including the exposure status of benzene, health effects, and derivation of the limit value. It also proposed prospects for the future direction of formulating indoor air benzene standards.
Humans
;
Air Pollution, Indoor/prevention & control*
;
Benzene/analysis*
;
Air Pollutants/analysis*
;
Environmental Pollutants
;
China
;
Environmental Monitoring
6.Study on formulation and revision of standard limit for formaldehyde in the "Standards for indoor air quality(GB/T 18883-2022)" in China.
Xiao Yan DONG ; Jiao WANG ; Xian Liang WANG ; Tian Tian LI ; Qin WANG ; Dong Qun XU
Chinese Journal of Preventive Medicine 2023;57(11):1748-1751
Formaldehyde, as an important pollutant in indoor air, has always been of great concern. In the newly issued "Standards for indoor air quality (GB/T 18883-2022)", the standard limit of formaldehyde has been restricted to 0.08 mg/m3. In order to better promote the implementation and application of this new standard, this study reviewed and interpreted the relevant technical content for determining the standard limit, including the indoor concentration and human exposure levels of formaldehyde, the health effects of formaldehyde, and the derivation of safety reference values. It also proposed prospect for the future development and revision of quality standards for formaldehyde in indoor air.
Humans
;
Air Pollution, Indoor
;
Air Pollutants/analysis*
;
Formaldehyde/analysis*
;
China
;
Environmental Pollutants
7.Study on revision of standard limits for benzene in"Standards for indoor air quality(GB/T 18883-2022)"in China.
Guo Min CHEN ; Tian Tian LI ; Yan Jun DU ; Shuai JIANG ; Dao Kui FANG ; Xiao Heng LI ; Ning LIU ; Shu Yuan YU
Chinese Journal of Preventive Medicine 2023;57(11):1752-1755
Benzene, as a major indoor pollutant, has received widespread attention. In order to better control indoor benzene pollution and protect people's health, the limit value of benzene in the"Standards for indoor air quality (GB/T 18883-2022)'' was reduced from 0.11 mg/m3 to 0.03 mg/m3. This study reviewed and discussed the relevant technical contents of the determination of benzene limit value, including the exposure status of benzene, health effects, and derivation of the limit value. It also proposed prospects for the future direction of formulating indoor air benzene standards.
Humans
;
Air Pollution, Indoor/prevention & control*
;
Benzene/analysis*
;
Air Pollutants/analysis*
;
Environmental Pollutants
;
China
;
Environmental Monitoring
9.Determination of o-chlorostyrene in the air of workplace by gas chromatography.
Wei CHEN ; Gui-Hua LIU ; Kai LIN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2011;29(2):152-153
OBJECTIVETo establish a rapid gas chromatographic method for determination of o-chlorostyrene in the air of workplace.
METHODThe air samples were collected by syringes, injected directly to the GC system, and then separated by a FFAP capillary column (30 m × 0.53 mm × 0.25 µm), finally determined by a Flame Ionization Detector.
RESULTSA good linear correlation was showed within a range of 0 ∼ 1200 µg/L, with regression formula Y = 14 030 + 7 207X (r = 0.9999). The air sample could be stably stored in the syringe for 5 hrs. The relative standard deviation (RSD) of repeated injection of o-chlorostyrene standard solutions at three different concentration by six times was 1.28% ∼ 1.97%. The minimum detectable concentration was calculated to be 5.2 mg/m(3). Other coexistent violative organic compounds such as styrene, p-chlorostyrene, and m-chlorostyrene didn't interfere with the determination under the experimental conditions of this method.
CONCLUSIONThis method meets the requirement of "Guide for establishing occupational health standards-Part 4: Determination methods of air chemicals in workplace". It is applicable for determination of o-chlorostyrene in the air of workplace.
Air Pollutants, Occupational ; analysis ; Chromatography, Gas ; methods ; Styrenes ; analysis ; Workplace