1.Evaluation of thermal environment and human thermal comfort in 8 types of public places from 2019 to 2021.
Jing Ying ZHU ; Xi ZHANG ; Chun Hua HUANG ; Lin WANG ; Rong CHEN ; Xin Liang DING
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(3):189-197
Objective: To evaluate the thermal environment of different types of public places and the thermal comfort of employees, so as to provide scientific basis for the establishment of microclimate standards and health supervision requirements. Methods: From June 2019 to December 2021, 50 public places (178 times) of 8 categories in Wuxi were selected, including hotels, swimming pools (gymnasiums), bathing places, shopping malls (supermarkets), barber shops, beauty shops, waiting rooms (bus station) and gyms. In summer and winter, microclimate indicators such as temperature and wind speed were measured in all kinds of places, combined with the work attire and physical activity of employees in the places. Fanger thermal comfort equation and center for the built environment (CBE) thermal comfort calculation tool were used to evaluate the predicted mean vote (PMV), predicted percent dissatisfied (PPD) and standard effective temperature (SET) according to the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 55-2020. The modification effects of seasonal and temperature control conditions on thermal comfort were analyzed. The consistency of GB 37488-2019 "Hygienic Indicators and Limits in Public Places" and ASHRAE 55-2020 evaluation results on thermal environment was compared. Results: The thermal sensation of hotel, barber shop staff and the gym front-desk staff were moderate, while the thermal sensation of swimming place lifeguard, bathing place cleaning staff and gym trainer were slightly warm in summer and winter. Waiting room (bus station) cleaning and working staff, shopping mall staff felt slightly warm in summer and moderate in winter. Service staff in bathing places felt slightly warm in winter, while staff in beauty salons felt slightly cool in winter. The thermal comfort compliance of hotel cleaning staff and shopping mall staff in summer was lower than that in winter (χ(2)=7.01, 7.22, P=0.008, 0.007). The thermal comfort compliance of shopping mall staff in the condition of air conditioning off was higher than that in the condition of air conditioning on (χ(2)=7.01, P=0.008). The SET values of front-desk staff in hotels with different health supervision levels were significantly different (F=3.30, P=0.024). The PPD value and SET value of the front-desk staff, and the PPD value of cleaning staff of hotels above three stars were lower than those of hotels below three stars (P<0.05). The thermal comfort compliance of front-desk staff and cleaning staff in hotels above three stars was higher than that in hotels below three stars (χ(2)=8.33, 8.09, P=0.016, 0.018). The consistency of the two criteria was highest among waiting room (bus station) staff (100.0%, 1/1) and lowest among gym front-desk staff (0%, 0/2) and waiting room (bus station) cleaning staff (0%, 0/1) . Conclusion: There are different degrees of thermal discomfort in different seasons, under the condition of air conditioning and health supervision, and the microclimate indicators can not fully reflect the thermal comfort of human body. The health supervision of microclimate should be strengthened, the applicability of health standard limit value should be evaluated in many aspects, and the thermal comfort of occupational group should be improved.
Humans
;
Temperature
;
Cold Temperature
;
Air Conditioning
;
Wind
;
Seasons
2.Efficacy of the Precise Climate Controller on the reduction of indoor microorganisms
Greetha MOUNGTHONG ; Pana KLAMKAM ; Prasit MAHAKIT ; Thanit CHALERMWATANACHAI ; Sudaluck THUNYAHARN ; Veerapol MONYAKUL
Asia Pacific Allergy 2014;4(2):113-118
BACKGROUND: Nowadays, there are many methods to reduce microorganisms in the air, such as dehumidifier, air purifier or humidity and temperature controller. The Precise Climate Controller is an instrument for controlling humidity and temperature, a concept that is demonstrated. OBJECTIVE: To determine the efficacy of this device, in order to reduce the quantity of the fungi and bacteria in the closed system.
Air Conditioning
;
Air Filters
;
Aspergillus flavus
;
Bacteria
;
Climate
;
Colony Count, Microbial
;
Fungi
;
Humidity
3.Hygienic investigation of indoor environment in air-conditioned passenger trains.
Xiupei ZHANG ; Jianmin MA ; Weijing ZHOU ; Liyu ZHOU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2002;20(1):19-22
OBJECTIVEExplore the hygienic status of indoor environment in railway air-conditioned passenger trains.
METHODSWe carried out a hygienic investigation of various air-conditioned passenger trains on total 10 railway lines in Shanghai, Chengtu, Kunming, Harbin, Urumchi and Guangzhou railway bureaus for two years between July, 1997 and Oct., 1999. The monitoring was conducted on difference train cars at different time, different railway status. The control groups were selected in the same condition.
RESULTSThe results of temperature and wind speed in air-conditioned trains both meet with the national standards GB 9673-1996 in summer and winter. The humidity in summer exceeded the national standards. Of different railways the status, the noise in four different cars except dining cars exceeded the national standards. The results of shock demonstrated that all measure up to the standards of ISO 2631/1-85. As to indoor air quality, the concentration of CO in air-conditioned trains in difference seasons(summer, autumn, winter) all met with the national standards, the ratio was 100%. In summer, the concentrations of CO2 in hard seat cars and soft berth car exceeded the national standard with a statistic significance(P < 0.01). In winter, the concentrations of CO2 in soft berth and hard berth cars both exceeded the same standard. The results of inhalable particulate matter(IP) and total count of bacteria all satisfied the standards, meanwhile the natural lighting and artificial illumination in air-conditioned train cars all were superior to that in ordinary trains.
CONCLUSIONHumidity in summer and noise in dining car exceeded the standards, the concentration of CO2 in different cars in summer and winter exceeded the standards in some degrees.
Air Conditioning ; Air Pollution, Indoor ; Carbon Dioxide ; analysis ; Environmental Monitoring ; Humidity ; Motor Vehicles ; standards ; Particulate Matter ; analysis ; Seasons
4.CO Intoxication in the Car: Case Report.
Bong Woo LEE ; Dae Young HUR ; Ho LEE ; Chan Sung PARK ; Jae Kun OH ; Joong Seok SEO
Korean Journal of Legal Medicine 2001;25(2):43-47
A man and a woman were found dead in their parked car. The car was placed in a deep embankment. The windows were rolled up. Since it was cold winter the engine and heater was running while soil surrounded the rear of the automobile. The cause of death was 87%, 85% carbon-monoxide blood saturation respectively. The source of the CO was a defective exhaust system, The tail pipe outlet was blocked by the soil, and fumes could not escape adequately. Carbon monoxide fumes might entered the vehicle through the rusted floorboards, air conditioning, and through the dash board. It is important to know that unintened carbon monoxide deaths from motor vehicle exhaust can occur outdoors in older vehicles with defective exhaust system. We suggest the public need to be aware of the potential for this life threatening hazard to occur so that there can be proper prevention of fatalities.
Air Conditioning
;
Automobiles
;
Carbon Monoxide
;
Cause of Death
;
Female
;
Humans
;
Motor Vehicles
;
Running
;
Soil
;
United Nations
5.Fungi in Indoor Environment.
Korean Journal of Medical Mycology 1998;3(2):73-80
The characters of modern buildings such as higher airtightness, frequent usage of artificial materials and artificial air conditionings provide suitable conditions for flourishing of microorganisms, especially fungi. Indoor fungi could produce unacceptable musty smells and cause structural damage of building. But the more serious effects are the threatening on human health. They could provoke several allergic diseases, sick building syndrome, organic dust toxic syndrome, and could be the important causative agents of infectious diseases in the immunocompromized host. This paper review the characters, physiology, epidemiology and isolation techniques of the indoor fungi to provide the basic ideas to control the indoor fungi.
Air Conditioning
;
Communicable Diseases
;
Dust
;
Epidemiology
;
Fungi*
;
Humans
;
Physiology
;
Sick Building Syndrome
;
Smell
6.A investigation of thirdhand smoke pollution in 3 types of places of Nanjing, 2014.
Shuxing ZHANG ; Shanlei QIAO ; Minjian CHEN ; Yankai XIA ; Bo HANG ; Senping CHENG
Chinese Journal of Preventive Medicine 2015;49(1):31-35
OBJECTIVETo investigate thirdhand smoke (THS) pollution in certain places of Nanjing, as well as to analyze its distribution characteristics.
METHODSFrom March to May, 2014, we selected 3 types of places (residencies, public places and transportation vehicles) that were close to people's living in Jianye,Yuhua,Jiangning,Xuanwu,Gulou and Pukou districts of Nanjing city.For each of the above 3 types of places, 2-3 smoking and non-smoking (smoking ban) locations were investigated, totally 51 locations, 9-10 samples were collected each location, totally 477 samples. The surface wipe sampling method in conjunction with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was utilized to quantify the levels of nicotine that served as the tracer of THS pollution.One-way ANOVA and t-tests were employed to compare the levels of nicotine collected at different places and locations.
RESULTSTotally 477 samples were collected in this study, of which 27.0% was from residencies (129/477), 61.0% (291/477) from public places and 11.9% (57/477) from transportations. The levels of indoor surface nicotine in smoking residences, public places and transportations were (214 ± 55),(1 408 ± 177) and (1 511 ± 785) µg/m(2), respectively, which were all higher than those in the corresponding non-smoking places ((23 ± 9),(62 ± 11), and (46 ± 15) µg/m(2); t values were 13.79, 13.15, 3.45, respectively. P values were <0.001, <0.001 and 0.006, respectively).In the smoking places, the levels of surface nicotine on walls, desks, sofas, cabinets, door backsides and air conditioning openings were (171 ± 62),(232 ± 38),(373 ± 151),(903 ± 239), (978 ± 212), (1 721 ± 517) µg/m(2) (F = 7.06, P = 0.009).In the smoking condition, the levels of surface nicotine collected from public places were higher (F = 9.25, P = 0.024), while under non-smoking (smoking ban) conditions, the levels of surface nicotine collected from residences were lower (F = 7.88, P < 0.001).
CONCLUSIONTHS pollution was widespread in public places, residences and transportations in Nanjing city, which was more serious in the smoking environments than non-smoking (smoking ban) environments; the contamination was less serious in non-smoking (smoking ban) private residences; in the smoking condition, the levels of surface nicotine were relatively high at locations close to air conditioning openings, door backsides and cabinets.
Air Conditioning ; China ; Housing ; Humans ; Nicotine ; Public Facilities ; Smoking ; Tandem Mass Spectrometry ; Tobacco Smoke Pollution ; Transportation
8.Impact of sinonasal anatomic changes after endoscopic anterior skull base surgery on nasal airflow and air conditioning: a computational fluid dynamics study.
Dong DONG ; Yu Lin ZHAO ; Chao WANG ; Jia Song TIAN ; Yu Dong ZHANG ; Rong Han WEI ; Xin Jie QIAO ; Ge GUO ; Tong Nan YIN ; Hao Jie HU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(5):445-451
Objective: To analyze the impact of the sinonasal anatomic changes after endonasal endoscopic anterior skull base surgery on the nasal airflow and heating and humidification by computational fluid dynamics (CFD), and to explore the correlation between the postoperative CFD parameters and the subjective symptoms of the patients. Methods: The clinical data in the Rhinology Department of the First Affiliated Hospital of Zhengzhou University from 2016 to 2021 were retrospectively analyzed. The patients received the endoscopic resection of the anterior skull base tumor were selected as the case group, and the adults whose CT scans had no sinonasal abnormalities were chosen as the control group. The CFD simulation was performed on the sinonasal models after reconstructed from the patients' sinus CT images during the post-surgical follow-up. All the patients were asked to complete the Empty Nose Syndrome 6-Item Questionnaire (ENS6Q) to assess the subjective symptoms. The comparison between two independent groups and the correlation analysis were carried out by using the Mann-Whitney U test and the Spearman correlation test in the SPSS 26.0 software. Results: Nineteen patients (including 8 males and 11 females, from 22 to 67 years old) in the case group and 2 patients (a male of 38 years old and a female of 45 years old) in the control group were enrolled in this study. After the anterior skull base surgery, the high-speed airflow moved to the upper part of the nasal cavity, and the lowest temperature shifted upwards on the choana. Comparing with the control group, the ratio of nasal mucosal surface area to nasal ventilation volume in the case group decreased [0.41 (0.40, 0.41) mm-1 vs 0.32 (0.30, 0.38) mm-1; Z=-2.04, P=0.041], the air flow in the upper and middle part of the nasal cavity increased [61.14 (59.78, 62.51)% vs 78.07 (76.22, 94.43)%; Z=-2.28, P=0.023], the nasal resistance decreased [0.024 (0.022, 0.026) Pa·s/ml vs 0.016 (0.009, 0.018) Pa·s/ml; Z=-2.29, P=0.022], the lowest temperature in the middle of the nasal cavity decreased [28.29 (27.23, 29.35)℃ vs 25.06 (24.07, 25.50)℃; Z=-2.28, P=0.023], the nasal heating efficiency decreased [98.74 (97.95, 99.52)% vs 82.16 (80.24, 86.91)%; Z=-2.28, P=0.023], the lowest relative humidity decreased [(79.62 (76.55, 82.69)% vs 73.28 (71.27, 75.05)%; Z=-2.28, P=0.023], and the nasal humidification efficiency decreased [99.50 (97.69, 101.30)% vs 86.09 (79.33, 87.16)%; Z=-2.28, P=0.023]. The ENS6Q total scores of all patients in the case group were less than 11 points. There was a moderate negative correlation between the proportion of the inferior airflow in the post-surgical nasal cavity negatively and the ENS6Q total scores (rs=-0.50, P=0.029). Conclusions: The sinonasal anatomic changes after the endoscopic anterior skull base surgery alter the nasal airflow patterns, reducing the efficiency of nasal heating and humidification. However, the post-surgical occurrence tendency of the empty nose syndrome is weak.
Adult
;
Humans
;
Male
;
Female
;
Young Adult
;
Middle Aged
;
Aged
;
Retrospective Studies
;
Hydrodynamics
;
Air Conditioning
;
Nose
;
Nasal Cavity
;
Skull Base/surgery*
9.Contamination status and molecular biological characteristics of Legionella in cooling water samples from different places in Wuxi city.
Qi ZHANG ; Rong CHEN ; Yong XIAO ; Bin LIU ; Tian QIN ; Zhu-Jun SHAO ; Wei-Jie ZHOU
Chinese Journal of Preventive Medicine 2012;46(3):264-268
OBJECTIVETo investigate the contamination state of Legionella in cooling water samples from different places in Wuxi city and reveal the molecular biological characteristics of Legionella strains.
METHODS112 parallel water samples (500 ml each) were collected from 56 sites in Wuxi city during year 2009 - 2010. The samples were used for Legionella test and quantitative culture. The isolated Legionella strains were used for serotyping, pulsed-field gel electrophoresis (PFGE), sequence-based typing (SBT), and intracellular growth were tested.
RESULTSThe positive proportion of Legionella was 39. 3% (22/56) among all sampling sites. A total of 29 Legionella strains were isolated, and the serotypes include LP1, LP3, LP5 and LP6. LP1 serotype was the major one with a proportion of 65.5% (19/29). 29 Legionella strains got 17 PFGE types. There were 10 SBT types among 10 Legionella strains with different PFGE types. Comparing to LP1 strain (ATCC 33152), WX2011062 (LP6) and WX2011067 (LP5) had strong intracellular growth ability in mouse peritoneal macrophages J774 cell line (the amount of intracellular bacteria on day 0 after infection were (5.5 +/- 1.32) x 10(5), (3.9 +/- 0.60) x 10(5), (7.8 +/- 0.76) x 10(5) CFU/ml, respectively; the amount of intracellular bacteria on day 3 after infection were (58.3 +/- 1.61) x 10(5), (2700.0 +/- 655.74) x 10(5), (3066.7 +/- 208.17) x 10(5) CFU/ml, respectively).
CONCLUSIONThe Legionella contamination existed in cooling water samples from different places in Wuxi city. Legionella strains isolated showed high genetic variation. Some Legionella strains had vigorous intracellular growth ability.
Air Conditioning ; Animals ; Cells, Cultured ; Environmental Microbiology ; Legionella ; genetics ; growth & development ; isolation & purification ; Legionella pneumophila ; growth & development ; isolation & purification ; Macrophages ; microbiology ; Mice ; Serotyping ; Water Microbiology
10.Prediction and analysis model of temperature and its application to a natural ventilation multi-span plastic greenhouse equipped with insect-proof screen.
Shu-zhen LIU ; Yong HE ; Yu-bao ZHANG ; Xiang-wen MIAO
Journal of Zhejiang University. Science. B 2005;6(6):523-529
The natural ventilation widely used in greenhouses has advantages of saving energy and reducing expense. In order to provide information for climate control of greenhouse, a model was developed to predict the variation of air temperature in the naturally ventilated greenhouse equipped with insect-proof screen. Roof ventilation and combined roof and sidewall ventilation were considered in the model. This model was validated against the results of experiments conducted in the greenhouse when the wind was parallel to the gutters. The model parameters were determined by the least squares method. In the used model, effects of wind speed and window opening height on the air temperature variation were analyzed. Comparison between two types of ventilation showed that there existed a necessary ventilation rate which results in air temperature decrease in natural ventilation under special climatic conditions. In our experiments when wind speed was less than 3.2 ms(-1), wind had a more gradual effect on greenhouse temperature for roof ventilation, compared with combined roof and sidewall ventilation, which had greater air temperature decrease than roof ventilation only.
Air Conditioning
;
instrumentation
;
methods
;
Air Movements
;
Computer Simulation
;
Computer-Aided Design
;
Equipment Design
;
Equipment Failure Analysis
;
methods
;
Insect Control
;
instrumentation
;
methods
;
Models, Theoretical
;
Plant Development
;
Plastics
;
Rheology
;
instrumentation
;
methods
;
Temperature
;
Wind