1.The influence of salmeterol with fluticasone on airway inflammation of patients with acute exacerbation chronic obstructive pulmonary disease
Wei LIU ; Xiaori HUANG ; Fengmei LIU ; Ailian YU ; Lin ZHAO
Chinese Journal of Primary Medicine and Pharmacy 2011;18(12):1616-1618
Objective To investigate the influence of salmeterol with fluticasone on airway inflammation of patients with acute exacerbation chronic obstructive pulmonary disease (COPD).Methods 40 COPD patients in the stage of acute exacerbation were randomly divided into salmeterol with fluticasone group( A group) and controll group (B group).Bronchial alveolar lavage( BAL) was performed as usual.The concentrations of IL-8 and TNF-α in bronchial alveolar lavage fluid(BALF) were measured by ELISA.The results were compared with that of 18 healthy volunteers.Results The levels of IL-8 and TNF-a in BALF of patients in A group(10.60 ± 1.42) μg/L, (14.80 ± 2.05) μg/Land B group( 10.77 ± 1.98) μg/L, (14.70 ± 2.03) μg/L were significantly higher than that of C group (3.40 ±0.65)μg/L, (4.67 ± 1.01) μg/L( all P <0.01) ;Before treatment,the levels of IL-8 and INF-α in BALF of A group( 10.60 ± 1.42)μg/L,(14.80 ±2.05) μg/L and B group( 10.77 ± 1.98) μg/L,(14.70 ±2.03) μg/L had no significant differences (all P > 0.05) ,and the concentrations of IL-8 and TNF-a in BALF in group A (4.39 ± 0.92)μg/L,(5.84 ±1.26) μg/L were significantly lower than that in group B(9.69 ± 1.43) μg/L, (12.88 ± 2.51) μg/L after two weeks treatment ( all P < 0.01).Conclusion Salmeterol with fluticasone could inhibit airway inflammation of COPD patients in the stage of acute exacerbation.
2.Application of in situ Y chromosomal hybridization in the detection of mesenchymal stem cells
Fenglan WU ; Xiaofei ZHOU ; Wei CAO ; Chao PENG ; Ailian LIU
Chinese Journal of Tissue Engineering Research 2009;13(45):8924-8928
BACKGROUND:Transplantation of mesenchymal stem cells (MSCs) to multiple sclerosis (MS) is a new developed treatment to be given more and more attention.However,whether the MSCs function by cell replacement after going cross the blood-brain barricr or immune suppression needs further confirmation.OBJECTIVE:To establish a steady and effective method of Y chromosome in situ hybridization (ISH) and to detect the distribution of MSCs in a mouse model with MS.DESIGN,TIME AND SETTING:The observational study was performed at the Laboratory of Molecular Immunology,Institute of Healthy Science from September 2007 to February 2009.MATERIALS:A total of 30 C57BL/6 mice,aged 6-8 weeks and weighing 15-20 g,were selected.Female mice were used to establish experimental autoimmune encephalomyelitis (EAE).METHODS:Y chromosme specific DNA probe labled with digoxine (DIG) was designed and ISH was performed to confirm that the designed probe was Y chromosome specific and biologically sensitive.We transplanted the MSCs from male mice into the female EAE mice,and tracked the MSCs by Y chromosome ISH.MAIN OUTCOME MEASRUES:Distribution of MSCs in mice with EAE was observed under the optical and fluorescence microscope.RESULTS:The probe was confirmed to be Y chromosome specific and biologically sensitive.What's more,a steady and effective method of ISH was established.Some MSCs were detected in the periphery organs-spleen and lymph node of mice with EAE;seldom in spinal cord which indicated that MSCs might play its roles by immune suppression.CONCLUSION:Some MSCs were detected in the periphery organs-spleen and lymph node of mice with EAE,but seldom in spinal cord in the central nervous system.
3.Diagnostic value of multi-parameter MRI in ovarian endometriosis
Ye LI ; Ailian LIU ; Meiyu SUN ; Shifeng TIAN ; Qingwei SONG
Chinese Journal of Radiology 2016;50(3):201-204
Objective To evaluate the feasibility of multi-parameter MRI in diagnosing ovarian endometrial cysts. Methods Pelvic MRI of 68 patients with confirmed pathological diagnosis were retrospectively reviewed. The patients were divided into ovarian endometriosis (35 patients with 42 lesions, group A) and other cystic lesions (33 patients with 38 lesions , group B).The signal intensity value of T1WI, T2WI of cyst fluid and iliopsoas, ADC value, phase values and R2*values were obtained, cyst fluid/iliopsoas ratios (T1R and T2R) were calculated. The non-parametric Mann-Whitney U test was employed to compare parameter values between the two groups. The values of diagnostic performance were analyzed by using receiver operating characteristic curve (ROC). Use the Logistics regression parameters of diagnostic efficacy to select the highest Youden index for the best parameter association after combining the parameters step by step. Results The median of T1R, T2R, ADC, phase, T1R and R2*values for group A were 3.39, 5.28, 1.20×10-3 mm2/s,2.19×10-2, 15.08 Hz respectively, and that of group B were 0.91, 10.85, 2.64×10-3mm2/s,2.67×10-2, 3.01 Hz, respectively. There were statistically significant difference between the two groups (P<0.01).The AUC of T1R, T2R, ADC value, phase values and R*2 value were 0.930, 0.874, 0.891, 0.685 and 0.924 respectively, and there was no difference among them (P>0.05). When combining T1R, ADC value, R2*value together, the Youden index (0.849 7) was highest. Conclusion Combining T1R, ADC and R2* values can provide an effective way to discriminate endometrial ovarian cyst from other ovary cystic lesions.
4.Renal vascular angiography with interpolated finite impulse response with 1.5T MR
Yi WANG ; Ailian LIU ; Qingwei SONG ; Meiyu SUN ; Heqing WANG
Chinese Journal of Medical Imaging Technology 2010;26(2):358-360
Objective To evaluate the feasibility of renal artery angiography with interpolated finite impulse response (IRFR) sequence on 1.5T MR. Methods A total of 122 subjects underwent MR scan with IFIR sequence. On axial image of IFIR, bilateral signal-to-noise ratio (SNR) and breath artifact of renal artery were measured and 3D maximum intensity projection (MIP) images were reconstructed on workstation ADW 4.3, and each branch was scored according to its displaying quality. Influence of SNR, age and breath artifact on the displaying of renal artery were compared and analyzed. Results Renal segmental artery could be seen in 112 subjects (91.80%). Among them, segmental artery was showed clearly in 78 subjects (63.93%), post-segmental artery was showed in 54 subjects (44.26%) and branches of post-segmental artery was showed in 22 subjects (18.03%). There was statistical difference of renal artery scores mean rank between ≥60 years group and <60 years group (49.25 vs 67.48, P=0.006), as well as between the group without and with breath artifact (66.66 vs 43.35, P=0.002). No statistical difference of SNR was found among renal artery scores from 1-5 (P=0.177). Conclusion IFIR sequence is simple and safe for renal artery angiography on 1.5T MR, and different grades of renal artery branch can be showed clearly.
5.CT and MRI manifestations of Kimura disease in head and neck
Chunfeng LI ; Yuan JI ; Lijun WANG ; Haitao WANG ; Ailian LIU
Chinese Journal of Medical Imaging Technology 2017;33(6):876-879
Objective To explore the CT and MRI manifestations of Kimura disease in head and neck.Methods The CT and MR findings of 20 cases with Kimura disease confirmed by pathology were collected.The lesion location,boundary,size,number,density of CT and signal intensity of MRI were analyzed.Results In 20 cases,multiple lesions were seen in 19 cases.There were 11 cases involving parotid gland,6 cases involving the submandibular area,2 cases in cheek,1 case in palate,2 cases involving the upper arm,1 case involving axillary fossa,1 case involving cervical lymph node alone,and 8 cases with subcutaneous nodules in the front or back of the ear,16 cases accompanied by lymphadenopathy in the neck (8 cases with lymphadenopathy in the parotid gland).The largest diameter of lesion was (3.09± 1.08)cm.The margin was blurred in 19 cases and well defined in 1 case.The isodensity lesions were found in 16 cases and slightly lower density lesions were in 4 cases in non-contrast enhanced CT scan.Calcification was not found in all cases.Homogeneous enhancement was found in 16 cases and inhomogeneous enhancement was found in 1 case.The enhancement degree varies from mild to strong enhancement.Homogenous signal and strong enhancement was found in 2 cases with MR scan.Conclusion The typical manifestations of Kimura disease are involvement of parotid gland and subcutaneous fat,accompanied by lymphadenopathy in the neck,homogeneous density on CT or MRI,which may indicate Kimura disease.
6.Immunogenicity of recombinant Lugurus zone pellucida-3 expressed in E.coli and efficacy of its antiserum to affect in vitro mouse sperm-egg binding in vitro
Ailian ZHANG ; Shuzhen ZHUANG ; Fei LIU ; Fuchun ZHANG
Chinese Journal of Immunology 1985;0(03):-
Objective:Present study was aimed to analyze the immunogenicity of recombinant Lugurus zona pellucida-3 protein (r-LZP3) expressed in E.coli,and to evaluate the efficacy of its antiserum to affect in vitro mouse sperm-egg binding.Methods:Female mouse were immunized using LZP3 DNA vaccine for priming,and boosted with r-LZP3 protein.The antibody response level of LZP3 antisera was determined by ELISA.The immunoreactivity and specificity of the anti-LZP3 antisera were tested by immunoblot, indirect immunofluorescence and immunohistochemistry using native mouse ZP.A sperm-zone pellucida binding assay was used to evaluate the efficacy of anti-LZP3 antisera to inhibit mouse sperm-egg binding in vitro.Results: The result of ELISA showed that LZP3 DNA vaccine was able to induce higher antibody titers in mouse.Antiserum could specifically recognize or bind to r-LZP3 protein expressed in E.coli and native mouse ZP in vitro.The LZP3 antisera and r-LZP3 protein also inhibited sperm-egg binding in vitro.Condusion:These results show that r-LZP3 protein is of strong immunogenicity.
7.MRI characteristics of solid papillary carcinomas in situ of breast
Li'na ZHANG ; Weisheng ZHANG ; Qingwei SONG ; Ailian LIU ; Shaowu WANG ;
Chinese Journal of Interventional Imaging and Therapy 2017;14(9):539-542
Objective To evaluate MRI characteristics of solid papillary carcinomas (SPCs) in situ of the breast.Methods A retrospective study included 5 patients with pathologically confirmed SPC in situ was performed.MRI data before operation including conventional MRI,dynamic contrast enhanced MRI (DCE-MRI) and DWI were analyzed.Results All the lesions showed iso/hypointensity on T1 FSPGR sequence,iso/hyperintensity on FSE T2WI sequence and STIR sequence.Mass enhancements were observed for all lesions with oval or irregular shapes on DCE-MRI.The margin of lesions were circumscribed,and internal enhancements were homogeneous or heterogeneous.Time intensity curve appeared a rapid increase in initial contrast phases and platform or outflow types in delayed phases.All the lesions on DWI showed slightly hyperintensity with the ADC value range from 1.34 × 10-3 mm2/s to 1.96)× 10-3 mm2/s.Conclusion MRI manifestations of SPC are characteristics,which may provide valuable information to distinguish SPC in situ from other invasive breast carcinomas.
8.Feasibility of low radiation dose and iodine contrast medium in 70 kVp abdominal CTA in low body mass index patients
Yijun LIU ; Ailian LIU ; Xin FANG ; Jinghong LIU ; Lei LIU ; Xiaofeng LIU ; Gang YUAN ; Renwang PU
Chinese Journal of Medical Imaging Technology 2017;33(3):473-477
Objective To explore the feasibility of reducing radiation dose and iodine contrast medium in 70 kVp abdominal CTA imaging in low-body mass index (BMI;≤22 kg/m2) patients.Methods The 48 patients with suspected abdominal vascular diseases and low BMI (≤22 kg/m2) underwent abdominal CTA.All patients were divided into two groups according to tube voltage and contrast intake randomly.The parameters of group A (n=27) were contrast intake 300 mgI/kg,70 kVp,the conditions of group B (n=21) were contrast intake 500 mgI/kg,120 kVp,and the other conditions were the same in both groups.The image quality of right renal arterial images was evaluated by two observers simultaneously (5-scale).The consistency and difference between the two observers were analyzed.The CT values of abdominal aorta,celiac trunk,superior mesenteric artery,common hepatic artery,pancreatic artery and erector spinae,SD values of erector spinae on the level of right renal hilus were measured respectively in both groups.The CT values of abdominal aorta and its main branches,the CNR of abdominal aorta,the volume CT dose index (CTDIvol),dose-length product (DLP) and overall iodine intake in each group were compared.Results The scoring of right renal arterial images in both groups were 5.00 (1.00),the results showed a good consistency (Kappa=0.932,0.911).The CT values of abdominal aorta,superior mesenteric artery,common hepatic artery and pancreatic artery in group A were all more than those of in group B (all P<0.05).The CNR of group A was higher than that of group B (P<0.05).The CTDIvoland DLP in group A decreased by 73.36% and 74.41% compared with group B.The overall iodine intakes in group A and group B were (46.33±6.43)ml and (84.31±10.71)rnl,respectively.The overall iodine intake of group A decreased by 45.05% compared with group B.Conclusion For patients with low BMI (≤22 kg/m2),a 70 kVp tube current abdominal CTA scanning can significantly increase the contrast of images of abdominal artery and its branches.Meanwhile,the radiation dose and overall iodine intake can obviously decrease.
9.Influence of Duration of Scan Acquisition on Perfusion Parameters of Whole Renal Perfusion by Wide Detector Multidetector CT
Jinghong LIU ; Ailian LIU ; Yimin WANG ; Xin FANG ; Yijun LIU ; Xiaofeng LIU ; Shifeng TIAN
Chinese Journal of Medical Imaging 2017;25(2):141-145
Purpose To explore the influence of duration of scan acquisition on perfusion parameters in whole renal perfusion with Revolution CT.Materials and Methods Fortytwo patients without pathologic changes in bilateral kidneys were divided into group A (with short perfusion time) and group B (with long perfusion time) according to the duration time of the perfusion scan.The Revolution CT axial scan mode was used for perfusion scan,and the width of detector was 16 cm.The perfusion CT series were performed in 50 seconds,each comprising 25 volumes with identical parameters (80 kVp,200 mA) in group A.The perfusion CT series were performed in 594 seconds,each comprising 23 volumes with identical parameters (120 kVp,55 mA) in group B.The source datasets were post-processed with CT Perfusion 4D software,and the perfusion parameter maps were obtained when right renal abdominal aorta was taken as entry artery.Perfusion parameters of bilateral kidneys were compared within and between group A and group B,respectively.CT dosage index of volume (CTDIvol) and dose length product (DLP) were recorded.The effective dose (ED) was calculated and compared.Results There were no statistical difference in all parameters between bilateral kidneys within each group (P>0.05).However,blood volume,time to peak,and permeability surface in the cortex and medulla of bilateral kidneys all showed differences between the above two groups (P<0.05).The mean transit time in the medulla between the two groups was different (P<0.05),but neither the blood flow in the medulla and cortex nor the mean transit time of the cortex had difference between the two groups (P>0.05).The effective radiation doses were (23.10± 4.39)mSv in group A and (23.19±0.00) mSv in group B,respectively (without statistic difference:P>0.05).Conclusion CT perfusion parameters with different duration time show differences in whole renal perfusion;therefore,scanning time needs to be set according to the clinical application.
10.The detection value of single source-dual energy CT for bladder cancer with hematoma
Yimin WANG ; Ailian LIU ; Jinghong LIU ; Yijun LIU ; Renwang PU ; Ye LI ; Anliang CHEN ; Zheng HAN
Journal of Practical Radiology 2016;32(8):1237-1241
Objective To assess the utility of single source-dual energy CT for distinguishing bladder cancer from hematoma. Methods We retrospectively identified 14 patients with postoperative or follow-up bladder hematoma who had undergone dual energy protocol (40-140 keV)scanning by single source-dual energy CT.The subjective scoring of tumor detection and image quality,the optimal monochrome images and iodine-water images were evaluated by two radiologists who didn’t know the results.The consistency of two observers was analyzed by Kappa test.Mann-Whitney U test was used to compare the difference between the two kinds of diseases and ROC curve was used to analyze the diagnostic efficiency.The statistical differences of image quality scoring among different images were obtained by using Mann-Whitney U test.Results The consistency of the two observers about scoring of lesion detection was good for all groups.There were statistical differences between two groups in non-enhanced phase and arterial phase of mixed-energy images,non-enhanced phase,arterial phase and delayed phase of optimal monochromatic images,and all phase of iodine-water images. The AUC of iodine-water images in the four phases (0.985,1.000,0.955,0.924,respectively)were all higher than that of polychrome unenhanced and arterial phase images (0.909,0.909).The diagnostic efficiency of arterial phase on iodine-water images was the highest.Sensitivity and specificity were both 100% when score was greater than 2.5.There was no statistical difference between two kinds of diseases on non-enhanced phase,delayed phases of mixed-energy or monochromatic images(P >0.05).There were no statistical differences in image quality scoring among the three groups with the same phases (P>0.05).Conclusion Optimal monochromatic images and iodine-water images of single source-dual energy CT are more effective than conventional CT in distinguishing bladder cancer from hematoma.