1.Instillation of Hyaluronic Acid via Electromotive Drug Administration Can Improve the Efficacy of Treatment in Patients With Interstitial Cystitis/Painful Bladder Syndrome: A Randomized Prospective Study.
Omer GULPINAR ; Ahmet Hakan HALILOGLU ; Mehmet Ilker GOKCE ; Nihat ARIKAN
Korean Journal of Urology 2014;55(5):354-359
PURPOSE: In the treatment of interstitial cystitis, intravesical hyaluronic acid application may be suggested as a treatment option. In this randomized prospective study, the authors aimed to identify whether instilling the hyaluronic acid with electromotive drug administration (EMDA) would increase the tissue uptake and improve the efficacy. MATERIALS AND METHODS: The data of 31 patients who had been diagnosed with bladder pain syndrome/interstitial cystitis (BPS/IC) between 2004 and 2005 were examined. The patients were randomized to two groups: patients in group A received hyaluronic acid directly with a catheter and patients in group B received hyaluronic acid with EMDA. The patients were followed for 24 months and the two groups were compared at certain time intervals. The primary end points of the study were visual analogue scale (VAS) score, global response assessment, and micturition frequency in 24 hours. RESULTS: There were 6 males and 25 females. The two groups were similar in baseline parameters. The decrease in VAS score and the micturition frequency in 24 hours were significantly lower with EMDA at months 6 and 12. The difference between the two groups was not significant at months 1 and 24. Also, treatment with EMDA, positive KCl test, and pretreatment voiding frequency >17 were associated with higher response rates. CONCLUSIONS: Hyaluronic acid installation is an effective glycosaminoglycan substitution therapy in patients with BPS/IC. Instillation of hyaluronic acid via EMDA can improve the efficacy of the treatment; however, lack of long-term efficacy is the major problem with this glycosaminoglycan substitution therapy.
Catheters
;
Cystitis
;
Cystitis, Interstitial
;
Female
;
Humans
;
Hyaluronic Acid*
;
Male
;
Prospective Studies*
;
Urinary Bladder*
;
Urination
2.Functional Outcomes and Long-term Durability of Artificial Urinary Sphincter Application: Review of 56 Patients With Long-term Follow-up.
Omer GULP?NAR ; Evren SUER ; Mehmet Ilker GOKCE ; Ahmet Hakan HALILOGLU ; Erdem OZTURK ; Nihat AR?KAN
Korean Journal of Urology 2013;54(6):373-376
PURPOSE: To evaluate the long-term outcomes of artificial urinary sphincter (AUS) implantation and to report the complication rates, including mechanical failure, erosion, and infection. MATERIALS AND METHODS: From June 1990 to May 2011, AUS (AMS 800) implantations were performed in 56 adult males by one surgeon. Various demographic and preoperative variables, surgical variables, and postoperative outcomes, including success and complication rates with a median follow-up of 96 months, were recorded retrospectively. RESULTS: The mean age of the patients at the time of AUS implantation was 61.8 (+/-14.2) years. During the follow-up period, the total complication rate was 41.1% (23 patients). The incidence of complications was significantly lower during the follow-up period after 48 months (p<0.05). Kaplan-Meier analysis revealed that 5- and 10-year failure-free rates were 50.3% and 45.2%, respectively. CONCLUSIONS: Long-term durability and functional outcomes are achievable for the AMS 800, but there are appreciable complication rates for erosion, mechanical failure, and infection of up to 30%.
Adult
;
Follow-Up Studies
;
Humans
;
Incidence
;
Kaplan-Meier Estimate
;
Male
;
Urinary Incontinence
;
Urinary Sphincter, Artificial