1.Clinical study of transcervical occlusion of patent ductus arteriosus via femoral artery guided by ultrasound
Bao SUN ; Duan CHENG ; Bo LI ; Guibao HE ; Haifeng WANG ; Ahati ; Elias ; Xi SHENG ; Jinpeng LI ; Sadam ; Hussain
Journal of Chinese Physician 2018;20(5):701-703,708
Objective To evaluate the efficacy and safety of transthoracic echocardiography (TTE) guided by transcatheter closure of patent ductus arteriosus (PDA) through the femoral artery.Methods From February 2016 to December 2017,53 patients with simple PDA were selected,the funnel type in 30 cases,cast type in 23 cases.All patients were guided by TTE and transcatheter closure of PDA through the femoral artery.The femoral artery was guided by TTE by establishing the orbit of the femoral artery-catheter-pulmonary artery to the right ventricle.The right ventricular septal defect was placed under the femoral artery approach,and the therapeutic effect was evaluated by echocardiography after occlusion.The outpatient visits were made at 1,3,and 6 months after operation.Results PDA closure was successfully completed under TTE guidance in 53 patients.In one adult PDA,the ultrasonic diagnosis of the inner diameter of the catheter was incorrect due to the image quality,which resulted in the replacement of the occluded device several times,but the occlusion was successful.The operative time was (30 ± 10)min.And the back diameter of the transcatheter closure device was (12 ± 6) mm and the murmur of the transmission sheath disappeared.There was no shunt between the main pulmonary artery and the main pulmonary artery,and the length of hospitalization was 3-4 days.No shunt signal was found at 1,3 and 6 months follow-up.Left atrial diameter (LAD) [(25.8 ± 6.1) mm vs (30.6 ± 8.4) mm] and left ventricular end diastolic diameter (LVEDD) [(38.5 ±9.1)mm vs (45.2 ± 11.5)mm],were decreased significantly (P <0.05).Conclusions It is safe and effective to block PDA by using femoral artery approach under the guidance of TTE,which avoids the damage of X-ray and contrast agent,and its prospect of clinical application is promising.
2.Clinical efficacy and application value of percutaneous interventional treatment for
Bao SUN ; Duan CHENG ; Bo LI ; Guibao HE ; Haifeng WANG ; Ahati ; Elias ; Xi SHENG ; Jinpeng LI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2021;28(08):921-927
Objective To investigate the clinical efficacy and application value of percutaneous interventional treatment for structural heart diseases under guidance of ultrasound. Methods The clinical data of 1 010 patients with structural heart diseases treated by transcutaneous ultrasound-guided occlusion in our hospital from December 2, 2015 to December 31, 2019 were retrospectively reviewed, including 360 males and 650 females, aged 1-50 years. There were 692 patients of atrial septal defect (603 with central type, 9 combined with arterial catheter, 80 with ethmoid type), 116 patent foramen ovale, 25 ventricular septal defects (3 combined with atrial septal defect), 132 patent ductus arteriosus, 32 pulmonary valve stenosis (3 combined with atrial defect), 1 main pulmonary artery window, and 3 aneurysm rupture of aortic sinus. All patients were diagnosed by transthoracic echocardiography (TTE) before operation. Treatment was accomplished intraoperatively through TTE or transesophageal echocardiography (TEE) via the femoral artery or femoral vein. After operation, echocardiography, electrocardiogram and chest radiograph were reexamined. Results Satisfactory results were obtained in 1 005 patients, and 1 patient failed to seal the ventricular defect and was repaired under direct vision, occluder detachment occurred in 5 patients after operation (3 patients of atrial septal defects underwent thoracotomy for Amplatzer device and were repaired, 1 patient of atrial septal defects was closed after removing Amplatzer device, 1 patient of patent ductus arteriosus underwent thoracotomy for Amplatzer device and was sutured), mild pulmonary valve regurgitation occurred after balloon dilation in 2 patients with pulmonary stenosis, a small amount of residual shunt was found in 2 patients with ventricular defect, which disappeared after 3 months of follow-up, and 1 patient of right bundle branch block occurred and disappeared after 1 week. After follow-up of 1-24 months, 3 patients of ethmoidal atrial septal defect were reexamined with mild shunt. The occluder was in good position and the pressure difference of pulmonary valve was significantly reduced. There was no complication such as hemolysis, arrhythmia, embolism or rupture of chordae tendinae. Conclusion Percutaneous transfemoral artery and vein guided by TTE or TEE is safe and effective, with little trauma, no radiation or contrast agent damage, and has significant clinical efficacy and application values.
3.Efficacy and safety of ultrasound-guided percutaneous retrograde closure of patent ductus arteriosus
SUN Bao ; CHENG Duan ; LI Bo ; HE Guibao ; WANG Haifeng ; Ahati Elias ; SHENG Xi ; LI Jinpeng ; Sadam Hussain
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2019;26(12):1208-1212
Objective To evaluate the efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with transthoracic echocardiography (TTE). Methods From February 2016 to November 2018, 98 patients of pure PDA were selected, including 43 patients of funnel type and 55 patients of tube type. There were 38 males and 60 females at age of 2-48 (9.8±10.4) years. All patients underwent TTE-guided retrograde closure of the PDA through the femoral artery to establish a femoral-abdominal aorta-thoracic aorta-ductus arteriosus-aorta-right ventricle trajectory.Under the guidance of TTE, a suitable closure umbrella was placed through the femoral artery. One month, 3 months, 6 months, 12 months after the surgery, the patients received out-patient clinical follow-up. Results Ninety eight patients were successfully occluded by TTE. The occluder was replaced many times in an adult PDA patient, but finally it was successfully plugged. The operation time was 33.2±5.8 min. The lumbar diameter was 12±6 mm. And the postoperative murmur disappeared. Ultrasound showed no shunt between the aorta and the pulmonary artery, and the postoperative hospital stay was 3-4 days. No shunt signal was found in 1, 3, 6, 12 months follow-up. Left atrial anteroposterior diameter (25.8±6.1 mm vs. 30.6±8.4 mm) and left ventricular end diastolic diameter (38.5±9.1 mm vs. 45.2±11.5 mm) were significantly smaller (P < 0.05). Conclusion TTE-guided transcatheter closure of PDA via femoral artery is a safe and effective method to avoid the damage of X-ray and contrast medium. The prospect of clinical application is good.
4.Efficacy analysis of esophageal ultrasound-guided percutaneous femoral artery closure for ventricular septal defect
Bao SUN ; Duan CHENG ; Bo LI ; Guibao HE ; Haifeng WANG ; Ahati ; Elias ; Xi SHENG ; Jinpeng LI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2021;28(12):1471-1475
Objective To investigate the effectiveness and safety of esophageal ultrasound-guided percutaneous femoral artery closure of ventricular septal defect (VSD). Methods The clinical data of 24 patients with congenital VSD in our hospital from March 2017 to December 2019 were retrospectively analyzed, including 6 males and 18 females, with a median age of 12 (3-42) years, weight of 32 (12-91) kg, and VSD diameter of 4 (3-7) mm. There were 3 patients with VSD combined with atrial septal defect. Results Twenty-four patients successfully underwent interventional closure of percutaneous femoral artery under esophageal ultrasound guidance, and the position and shape of the occluders were good. The operation time was 45 (39-54) min, and the waist size of the occluders was 7 (5-12) mm. Among the patients, 14 patients used symmetric ventricular occlusion devices, 8 patients used asymmetric ventricular occlusion devices, and 2 patients used ventricular occlusion muscle occluders. Small amount of residual shunt occurred in 2 patients after the operation and it disappeared 3 months after the operation. One patient with right bundle branch block, which disappeared after 1 week of observation. There were no complications such as occluder closure, pericardial effusion or valve regurgitation during the perioperative period. During the follow-up period [3-18 (9.25±5.04) months], no serious complication occurred. Conclusion Transesophageal ultrasound-guided transfemoral artery occlusion for VSD is simple and safe, and it avoids the damage of radiation and contrast medium. It has advantages over traditional percutaneous interventional occlusion therapy.
5.Treatment of patent ductus arteriosus via ultrasound-guided percutaneous antegrade or retrograde access: A retrospective cohort study
Bao SUN ; Duan CHENG ; Bo LI ; Guibao HE ; Haifeng WANG ; Ahati ; Elias ; Xi SHENG ; Jinpeng LI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2022;29(08):1020-1023
Objective To compare the surgical results of ultrasound-guided percutaneous antegrade or retrograde therapy in the treatment of patent ductus arteriosus. Methods The clinical data of 166 patients (44 males and 122 females) who underwent transthoracic echocardiography guided closure of patent ductus arteriosus in Xinjiang Cardiovascular and Cerebrovascular Disease Hospital from February 2016 to August 2020 were retrospectively analyzed, and the patients were divided into two groups: an antegrade group (n=60) and a retrograde group (n=106). The operation time, success rate, bed rest time, postoperative complications and surgical safety were compared between the two groups. Results The immediate success rate of the two groups was 100.0%. Compared with the retrograde group, the antegrade group had shorter time of bed rest and hospital stay, but longer operation time. In the retrograde group, there were 2 patients of complications, including occlusive device falling off to pulmonary artery 12 hours after the operation in 1 patient, and false arterial tumor in 1 patient. Both groups were followed up for 3-18 months, and there was no death in the whole group. Conclusion It is safe and effective to block patent ductus arteriosus under the guidance of transthoracic echocardiography. Although the operation process of anterior occlusion of patent ductus arteriosus is slightly complex and the operation time is long, the indication is wide, and the bed rest time is short. Therefore it can be used as the first choice for patent ductus arteriosus occlusion.
6.Evaluation of the effectiveness of transcatheter closure of fenestrated atrial septal defect via femoral vein under ultrasound guidance
SUN Bao ; CHENG Duan ; LI Bo ; HE Guibao ; WANG Haifeng ; Ahati ; Elias ; SHENG Xi ; LI Jinpeng ; Saddam Hussein ; YU Guojun ; ZHAN Shusheng ; ZHANG Ling
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2019;26(9):889-894
Objective To introduce the application of transcatheter closure of multi-fenestrated atrial septal defect (ASD) via femoral vein under ultrasound guidance with amplatzer cribriform occluder (ACO) and atrial septal defect occluder (ASDO), as well as to assess its feasibility, effectiveness and safety. Methods The clinical data of 48 patients with fenestrated ASD occluded via femoral vein under ultrasound guidance from December 2015 to May 2018 in our hospital were retrospectively analyzed, including 17 males and 31 females, aged 10 months to 51 years, an average of 11.50±13.86 years, and weighting 6-79 (27.00±20.14) kg. Among 48 patients with fenestrated ASD, 12 patients had double-foramen and 13 atrial septal aneurysm combined with defects and 23 multi-foramen. All patients underwent transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE) to complete the closure of fenestrated ASD. Ultrasound, electrocardiogram and chest X-ray were reviewed the next day after surgery to evaluate the curative effect. Results Forty-eight patients with ASD were treated with 49 occluders, due to one patient with two occluders. There were 29 ASDO (8-26 mm) and 20 ACO (18-34 mm). During the operation, TTE/TEE examination showed that 48 patients were completely occluded, 13 patients showed fine bundle shunt in the unreleased push notification rod, and 9 patients had fine bundle shunt after the release of push notification rod. Fine bundle shunt was found in 8 patients 24 hours after operation, and microshunt was found in 3 patients 1 year after operation. All the patients were followed up. The occluder position was good. The right heart was reduced in different degrees, and the X-ray showed that the pulmonary blood was reduced in different degrees. No arrhythmia was found by electrocardiogram after operation. Conclusion It is a safe and effective method to use ACO and ASDO to occlude ASD through femoral approach under ultrasound guidance.