1.Standardization of ABO Antibody Titer Measurement at Laboratories in Korea.
Annals of Laboratory Medicine 2014;34(6):456-462
BACKGROUND: Measurement of the ABO antibody (Ab) titer is important in ABO-incompatible transplantation. However, to the best of our knowledge, no standard protocol or external survey program to measure the ABO Ab titer has been established in Korea. We investigated the current status of ABO Ab titer measurements at various laboratories in Korea and the impact of the protocol provided to reduce interlaboratory variations in the methods and results of ABO Ab titers. METHODS: The Korean external quality assessment of blood bank laboratories sent external survey samples with a questionnaire to 68 laboratories across Korea for the measurement of ABO Ab titers in May 2012. After 6 months, a second set of survey samples were sent with a standard protocol to 53 of the previously surveyed laboratories. The protocol recommended incubation at room temperature only and use of the indirect antihuman globulin method for the tube test as well as and the column agglutination test (CAT). RESULTS: Several interlaboratory variations were observed in the results, technical procedures, and methods selected for measurement. We found that 80.4% laboratories hoped to change their protocol to the provisional one. Additionally, CAT showed significantly lower variation among laboratories (P=0.006) than the tube test. CONCLUSIONS: Our study provides baseline data regarding the current status of ABO Ab titer measurement in Korea. The standard protocol and external survey were helpful to standardize the technical procedures and select methods for ABO Ab titer measurement.
ABO Blood-Group System/*immunology
;
Agglutination Tests/*standards
;
Antibodies/*analysis
;
Humans
;
Immunoglobulin G/analysis
;
Immunoglobulin M/analysis
;
Laboratories/*standards
;
Questionnaires
;
Republic of Korea
;
Temperature
2.Preparation and characterization of follwing the national standard anti-Brucella abortus serum, bovine.
Cui LI ; Fushi GUAN ; Zhihong DAI ; Hui JIANG ; Fang WEN ; Lianshou LU ; Zaishi WANG
Chinese Journal of Biotechnology 2011;27(5):812-816
To prepare anti-Brucella abortus serum used for calibrate the agglutination test follwing the national standard, 4 anti-Brucella abortus sera were obtained from 4 cows infected with Brucella abortus naturally. By potency testing, the third serum was selected. Sterility, vaccum degree, residual moisture, uniformity and stability of this standard material were tested and proved to meet the national standard. Referring to the international standard, RBT (Rose-Bengal plate agglutination test), SAT (standard tube agglutination) and CFT (complement fixation test) titers of this standard material were measured to be 1:160 "+" 1:2 400 "++" and 1:800 "++", which are identical with the collaborative assay results. International unit of the standard material is 4 000 IU/mL.
Agglutination Tests
;
veterinary
;
Animals
;
Antibodies, Bacterial
;
blood
;
Antigens, Bacterial
;
immunology
;
Brucella abortus
;
immunology
;
Brucellosis, Bovine
;
diagnosis
;
Cattle
;
China
;
Complement Fixation Tests
;
veterinary
;
Immune Sera
;
Reference Standards
3.Comparison of ABO Antibody Titers on the Basis of the Antibody Detection Method Used.
Seon Joo KANG ; Young Ae LIM ; Sae Yun BAIK
Annals of Laboratory Medicine 2014;34(4):300-306
BACKGROUND: Detection methods for ABO antibody (Ab) titers vary across laboratories, and the results are different depending on the method used. We aimed to compare titer values using different detection methods for the measurement of ABO Ab titers. METHODS: For ABO Ab detection, pooled group A or B red blood cells (RBCs) were reacted with each of 20 sera from blood groups A, B, or O without dithiothreitol treatment. The room-temperature (RT) incubation technique and the indirect antiglobulin test (IAT) were used in the tube test and gel card test. Flow cytometry (FCM) was performed by using anti-IgM and anti-IgG Abs. RESULTS: Regardless of the blood groups tested, the FCM assay with anti-IgM showed the highest titer compared to the tube test and gel card test with RT incubation in both. The tube test with IAT showed a higher titer than the gel card test with IAT (Gel-IAT) or FCM with anti-IgG in blood group A and B, while Gel-IAT showed the highest titer relative to the other tests, only for the anti-A Ab in blood group O. CONCLUSIONS: There were significant differences in the titers depending on the detection method used, and each method showed a different detection capacity for each ABO Ab depending on the ABO blood group tested. Therefore, caution should be exercised in interpreting ABO Ab titer results, taking into consideration the detection method used and the blood group.
ABO Blood-Group System/*immunology
;
Adult
;
Aged
;
Agglutination Tests/instrumentation/*standards
;
Antibodies/*analysis
;
Antibodies, Anti-Idiotypic/analysis
;
Erythrocytes/chemistry/metabolism
;
Female
;
*Flow Cytometry
;
Humans
;
Male
;
Middle Aged
;
Temperature