1.Large-Scale in-House Cell-Based Assay for Evaluating the Serostatus in Patients with Neuromyelitis Optica Spectrum Disorder Based on New Diagnostic Criteria.
Yeseul KIM ; Gayoung KIM ; Byung Soo KONG ; Ji Eun LEE ; Yu Mi OH ; Jae Won HYUN ; Su Hyun KIM ; AeRan JOUNG ; Byoung Joon KIM ; Kyungho CHOI ; Ho Jin KIM
Journal of Clinical Neurology 2017;13(2):175-180
BACKGROUND AND PURPOSE: The detection of aquaporin 4-IgG (AQP4-IgG) is now a critical diagnostic criterion for neuromyelitis optica spectrum disorder (NMOSD). To evaluate the serostatus of NMOSD patients based on the 2015 new diagnostic criteria using a new in-house cell-based assay (CBA). METHODS: We generated a stable cell line using internal ribosome entry site-containing bicistronic vectors, which allow the simultaneous expression of two proteins (AQP4 and green fluorescent protein) separately from the same RNA transcript. We performed in-house CBA using serum from 386 patients: 178 NMOSD patients diagnosed according to the new diagnostic criteria without AQP4-IgG, 63 high risk NMOSD patients presenting 1 of the 6 core clinical characteristics of NMOSD but not fulfilling dissemination in space, and 145 patients with other neurological diseases, including 66 with multiple sclerosis. The serostatus of 111 definite and high risk NMOSD patients were also tested using a commercial CBA kit with identical serum to evaluate the correlation between the 2 methods. All assays were performed by two independent and blinded investigators. RESULTS: Our in-house assay yielded a specificity of 100% and sensitivities of 80% (142 of 178) and 76% (48 of 63) when detecting definite- and high risk NMOSD patients, respectively. The comparison with the commercial CBA kit revealed a correlation for 102 of the 111 patients: no correlation was present in 7 patients who were seronegative using the commercial method but seropositive using the in-house method, and in 2 patients who were seropositive using the commercial method but seronegative using the in-house method. CONCLUSIONS: These results demonstrate that our in-house CBA is a highly specific and sensitive method for detecting AQP4-IgG in NMOSD patients.
Aquaporin 4
;
Cell Line
;
Humans
;
Methods
;
Multiple Sclerosis
;
Neuromyelitis Optica*
;
Research Personnel
;
Ribosomes
;
RNA
;
Sensitivity and Specificity
2.Development of a Rapid Automated Fluorescent Lateral Flow Immunoassay to Detect Hepatitis B Surface Antigen (HBsAg), Antibody to HBsAg, and Antibody to Hepatitis C.
Ji Hyeong RYU ; Minsuk KWON ; Joung Dae MOON ; Min Woong HWANG ; Jeong Min LEE ; Ki Hyun PARK ; So Jeong YUN ; Hyun Jin BAE ; Aeran CHOI ; Hyeyoung LEE ; Bongsu JUNG ; Juhee JEONG ; Kyungja HAN ; Yonggoo KIM ; Eun Jee OH
Annals of Laboratory Medicine 2018;38(6):578-584
BACKGROUND: Accurate, rapid, and cost-effective screening tests for hepatitis B virus (HBV) and hepatitis C virus (HCV) infection may be useful in laboratories that cannot afford automated chemiluminescent immunoassays (CLIAs). We evaluated the diagnostic performance of a novel rapid automated fluorescent lateral flow immunoassay (LFIA). METHODS: A fluorescent LFIA using a small bench-top fluorescence reader, Automated Fluorescent Immunoassay System (AFIAS; Boditech Med Inc., Chuncheon, Korea), was developed for qualitative detection of hepatitis B surface antigen (HBsAg), antibody to HBsAg (anti-HBs), and antibody to HCV (anti-HCV) within 20 minutes. We compared the diagnostic performance of AFIAS with that of automated CLIAs—Elecsys (Roche Diagnostics GmbH, Penzberg, Germany) and ARCHITECT (Abbott Laboratories, Abbott Park, IL, USA)—using 20 seroconversion panels and 3,500 clinical serum samples. RESULTS: Evaluation with the seroconversion panels demonstrated that AFIAS had adequate sensitivity for HBsAg and anti-HCV detection. From the clinical samples, AFIAS sensitivity and specificity were 99.8% and 99.3% for the HBsAg test, 100.0% and 100.0% for the anti-HBs test, and 98.8% and 99.1% for the anti-HCV test, respectively. Its agreement rates with the Elecsys HBsAg, anti-HBs, and anti-HCV detection assays were 99.4%, 100.0%, and 99.0%, respectively. AFIAS detected all samples with HBsAg genotypes A-F and H and anti-HCV genotypes 1, 1a, 1b, 2a, 2b, 4, and 6. Cross-reactivity with other infections was not observed. CONCLUSIONS: The AFIAS HBsAg, anti-HBs, and anti-HCV tests demonstrated diagnostic performance equivalent to current automated CLIAs. AFIAS could be used for a large-scale HBV or HCV screening in low-resource laboratories or low-to middle-income areas.
Fluorescence
;
Gangwon-do
;
Genotype
;
Hepacivirus
;
Hepatitis B Surface Antigens*
;
Hepatitis B virus
;
Hepatitis B*
;
Hepatitis C*
;
Hepatitis*
;
Immunoassay*
;
Mass Screening
;
Sensitivity and Specificity
;
Seroconversion
3.Neutralizing Antibodies Against Interferon-Beta in Korean Patients with Multiple Sclerosis.
Jae Won HYUN ; Gayoung KIM ; Yeseul KIM ; Byungsoo KONG ; AeRan JOUNG ; Na Young PARK ; Hyunmin JANG ; Hyun June SHIN ; Su Hyun KIM ; Suk Won AHN ; Ha Young SHIN ; So Young HUH ; Woojun KIM ; Min Su PARK ; Byung Jo KIM ; Byoung Joon KIM ; Jeeyoung OH ; Ho Jin KIM
Journal of Clinical Neurology 2018;14(2):186-190
BACKGROUND AND PURPOSE: Patients treated with interferon-beta (IFN-β) can develop neutralizing antibodies (NAbs) against IFN-β that can negatively affect the therapeutic response. This study assessed the prevalence of NAbs and the impact of NAb positivity on the therapeutic response to IFN-β in Korean patients with multiple sclerosis (MS). METHODS: This was a multicenter study involving 150 MS patients from 9 Korean medical centers who were treated with IFN-β for at least 6 months. Sera that had not been influenced by acute treatment were assessed for NAbs using a luciferase reporter gene assay. To evaluate the association between persistent positivity for NAbs and disease activity, NAbs were tested at 2 different time points in 75 of the 150 patients. Disease activity was defined as the presence of clinical exacerbations and/or active MRI lesions during a 1-year follow-up after NAb positivity was confirmed. RESULTS: NAbs were found in 39 of the 150 (26%) MS patients: 30 of the 85 (35%) who were treated with subcutaneous IFN-β-1b, 9 of the 60 (15%) who were treated with subcutaneous IFN-β-1a, and 0 of the 5 (0%) who were treated with intramuscular IFN-β-1a. Thirty of the 39 patients exhibiting NAb positivity were tested at different time points, and 20 of them exhibited persistent NAb positivity. Disease activity was observed more frequently in patients with persistent NAb positivity than in those with transient positivity or persistent negativity [16/20 (80%) vs. 4/55 (7%), respectively; p < 0.001]. When disease activity was compared between patients with persistent and transient NAb positivity, the difference was unchanged and remained statistically significant [16/20 (80%) vs. 2/10 (20%), p=0.004]. CONCLUSIONS: These results further support that persistent NAb positivity is associated with disease activity in MS patients treated with IFN-β.
Antibodies, Neutralizing*
;
Follow-Up Studies
;
Genes, Reporter
;
Humans
;
Interferon-beta*
;
Luciferases
;
Magnetic Resonance Imaging
;
Multiple Sclerosis*
;
Prevalence