1.The effects of long-term Mulanquan exercise on free radical metabolism and nitric oxide in middle aged and elderly women
Chinese Journal of Physical Medicine and Rehabilitation 2003;0(07):-
Objective To observe the effects of long-term Mulanquan exercise on antioxidative capacity and vasodilation.To elucidate the mechanism by which Mulanquan regulates endothelial endocrine function.To provide scientific evidence for Mulanquan's regulating blood pressure,improving cardiovascular function and preventing cardi- ovascular disease.Methods Forty-nine women volunteers were divided into an exercise group and a control group. They were fifty to sixty years old.The exercise group included 27 subjects who had practiced mulanquan regularly for at least two years.The control group comprised 22 subjects who had no habit of exercise.Their levels of serum ma- londialdehyde(MDA),superoxide dismutase(SOD),glutathione peroxidase(GSH-Px),catalase(CAT)and nitric ox- ide(NO)were quantitatively determined.Results①Serum MDA was lower in the exercise group than in the con- trol group,and the difference between the two groups was highly significant statistically.Serum SOD activity and GSH-Px activity in the exercise group were higher than in the control group,the differences between the two groups being highly significant statistically.There was no significant difference between the groups in serum CAT activity. The serum NO content of the exercise group was higher than that of the controls,with the inter-group difference statis- tically significant.②Serum NO content was positively correlated with SOD activity ,GSH-Px activity,and SOD/MDA, and negatively correlated with MDA content.Conclusion Long-term Mulanquan exercise can suppress lipid peroxi- dation in middle aged and aged women.It can help maintain high antioxidative capacity,increase the secretion of NO,and thus limit any decrease in endothelium-dependent vasodilatation,which will be good for regulating blood pressure and preventing cardiovascular disease.
3.Research on the design of an infusion pump system
China Medical Equipment 2013;(12):29-30,31
Objective: To design one kind of medical infusion pump. Methods: Based on single-chip microcomputer, 89C52, use the stepper motor to drive the semi extrusion micro flow pump. Results:During the infusion it can real-time monitor the block and bubble in the pipeline and alarm. It can accurately control the transfusion speed and infusion volume. With friendly man-machine interface it can display real-time infusion parameters and alarm signals. Conclusion: The infusion pump system has high precision and reliability, perfect function, and it is easy to use. Clinical practices show that it can effectively reduce the workload of the clinical nursing staff and improve work efficiency. It has high application value.
4.Observation of the Stability of Mezlocillin Sodium in Infusion Fluids Using Orthogonal Test
China Pharmacy 2001;12(6):269-270
OBJECTIVE: To observe the stability of mezlocillin sodium in 5% glucose injection, glucose and sodium chloride injection and maintain solution for infants injection with different pH, over different periods and at 4℃ , 25℃ , 37℃ .METHODS: 9 solutions with different pH were made up by mezlocillin sodium and above-mentioned infusion fluids, according to 4 factors and 3 levels to make L9(34) orthogonal test.Then determination of mezlocillin sodium in each solution was carried out with ultraviolet spectrophotometry.RESULTS: The contents of mezlocillin sodium in above-mentioned solutions with different pH and at different temperature have not changed obviously over 0h-8h.CONCLUSION: Mezlocillin sodium is compatible with above-mentioned solutions.
5.Clinical features and visual function of recurrent neuromyelitis optica
Chinese Journal of Ocular Fundus Diseases 2013;(3):240-244
Objective To observe the clinical features and visual function of recurrent neuromyelitis optica (NMO).Methods Thirty-four patients with NMO were enrolled in this retrospective case series study.The patients included two males and 32 females.The average first onset age was (35.03± 14.56) years old and the average recurrent rate were (4.24±2.45) times.The recurrent rate of optic neuritis (ON) ranged from two to 12 times.The recurrent rate of ON was two times in 15 eyes of 10 patients,≥three times in 37 eyes of 24 patients.Vision acuity,direct ophthalmoscope,fundus pre-set lens examination,visual field and visual evoked potential (VEP) were evaluated.Clinical features were observed.The abnormal rate of optic nerve including optic edema and atrophy; abnormal rate of visual field including decreasing retinal sensitivity,central and paracentral scotoma,ring scotoma,half field defects,tunnel visual field,visual field centrality constriction; abnormal rate of VEP including Prolonged latent phase and/or decreasing amplitude of P100 wave from patients of first episode or recurrence was analyzed.Serum NMO-IgG was detected from 28 patients hy indirect immunofluorescence technique to observe its positive rate.Results All patients were characterized by repeated episodes of ON and myelitis.The main clinical feature of ON was visual loss,and the main clinical features of myelitis included sensory disability,dyskinesia and vesicorectal disorder.Blindness rate was 41.67% after the first attack of ON,33.33% after two relapses,and 64.86% after ≥ three relapses.The difference of blindness rate between first attack and two episodes was not significant (x2=0.270,P=0.603).However,the blindness rate in patients having ≥ three episodes was significantly higher than those having two episodes (x2=4.300,P=0.038).With recurrence rate increasing,the abnormal rate of the optic nerve (x2 =6.750,P =0.034) and VEP(x2 =6.990,P =0.030)increased.But the abnormal rate of visual field did not increase along with recurrent rate (x2 =0.660,P=0.718).Seropositive rate of NMO-IgG did not differ significantly between patients with first attack ON and that with recurrent ON (x2 =1.510,P =0.470).But the seropositive patients had significantly higher bilateral blindness rate than seronegative patients (x2=5.063,P=0.027).Conclusions NMO are characterized by recurrent ON and myelitis.Visual loss,sensory disability,dyskinesia and vesicorectal disorder are the main clinical features.With recurrence rate increasing,the blindness rate,abnormalities the optic nerve and the abnormity rate of VEP increase.Seropositive recurrent NMO patients have higher bilateral blindness rate than seronegative patients.
6.Clinical Analysis of 86 Cases with Preeclampsia Complications
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(12):-
Objective To explore the clinical features,maternal and fetal outcome in preeclampsia complications.(Methods)Clinical data of 86 cases of preeclampsia complications in heart,liver,kidney and brain were analyzed retrospectively.All the patients were divided into two groups: early onset preeclampsia(EOPE) group,36 cases,onset gestational weeks
7.Study on the nasal colonization of Staphylococcus aureus among healthcare workers in a hospital in Shaanxi Province
ZHENG Gezhi ; DU Juan ; WEN Juan ; ZHANG Liang ; HE Yingli
China Tropical Medicine 2023;23(9):954-
Abstract: Objective To determine the rate of nasal carriage Staphylococcus aureus among healthcare workers in Department of Infectious Diseases department of the First Affiliated Hospital of Xi'an Jiaotong University Hospital, and to perform characterization on isolated strains. Methods A cross-sectional study was performed on 86 healthcare workers from February 2022 to June. Nasal swabs were collected from the healthcare workers, and S. aureus were identified after incubation. Antibiotic susceptibility, including chlorhexidine and mupirocin, was assessed by disk diffusion and minimal inhibitory concentration method. The PCR technique was used to detect the biocide resistance genes (qacAB, smr, lmrS mepA, and sepA), virulence genes (pvl, fnbA/fnbB, sea, seb, sec, sed, tst, eta, etb) and mecA gene. SCCmec typing and multilocus sequence typing was performed. For mupirocin-resistant strains, PCR amplification and sequencing were used to identify whether the strains had ileS gene mutations or carried resistant genes (mupA and mupB). Results S. aureus was isolated from 37 of the 86 healthcare workers (43.02%) , including 13 methicillin-resistant Staphylococcus aureus (MRSA) strains. The strains showed low resistance rates to levofloxacin (2.70%, 1/37), chloramphenicol (8.11%, 3/37), tetracycline (8.11%, 3/37), gentamicin (10.81%, 4/37), and ciprofloxacin (10.81%, 4/37). A total of 17 strains were identified as multidrug-resistant strains. Four SCCmec types were identified in MRSA strains, with the type II being the most frequent (53.85%, 7/13), followed by type IV (30.77%, 4/13). ST59 (46.15%, 6/13) was the most frequent among MRSA strains, while ST5 (41.67%, 10/24) was the most frequent among methicillin-susceptible S. aureus (MSSA) strains. sea was the most frequent virulence gene (56.76%, 21/37). sepA and mepA were detected in all 37 isolates. One Staphylococcus aureus strain was not sensitive to chlorhexidine, two strains had the missense mutation V588F (G1762T) and showed low level resistance to mupirocin, and one strain carrying mupA gene was highly resistant to mupirocin. Conclusion The nasal colonization rate of Staphylococcus aureus among healthcare worker in the investigated hospital was high, indicating a risk for nosocomial infections. Strengthened monitoring and decolonization treatment should be carried out to reduce these risks.
8.Three-dimensional gait analysis and case-control follow-up observation following total knee replacement
Juan LIANG ; Yuehong BAI ; Jun ZHOU
Chinese Journal of Tissue Engineering Research 2007;0(44):-
BACKGROUND:Evaluation plan for the neuro-musculo-skeletal system model and motor function was little.However,the three-dimensional gait analysis can transfer qualitative analysis and object description which widely used in orthopedics and rehabilitation medicine to quantitative evaluation with more objective and precise.OBJECTIVE:To evaluate gait kinematics and kinetic changes after total knee replacement based on 12 months follow up using three-dimensional gait analysis.DESIGN,TIME AND SETTING:The comparative observation and case-control study was performed in the Gait Analysis Room of the Department of Rehabilitation Medicine in the Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University from January 2007 to May 2008.PARTICIPANTS:Ten patients with knee osteoarthritis following total knee replacement were chosen as treatment group;concurrently,ten patients whose baseline data were matched with the treatment group without problems in nerve,muscle,skeletal system and equilibrium were selected as the control group.METHODS:Ten patients in the treatment group underwent rehabilitation training,then compared time-distance,kinematic,and mechanical parameters which were measured at 3,6,12 months after total knee replacement with the control group.MAIN OUTCOME MEASURES:Time-distance parameter,kinematic parameter,mechanical parameter and knee functional scores.RESULTS:Pace,step frequency,gait speed,and time of injured leg standing were notably decreased,while time of uninjured leg standing,duration of gait cycle were obvious prolonged compared with the control group(P
9.Changes in the gait analysis associated parameters of healthy people and patients with joint disease
Yuehong BAI ; Jun ZHOU ; Juan LIANG
Chinese Journal of Tissue Engineering Research 2007;11(9):1790-1793
BACKGROUND:Gait analysis enable to convert qualitative analysis and description used for a long time in orthopedic examination and rehabilitative treatment into objective and precise quantitative assessment. At the present, with the development of science and technology, three-dimensional (3D) gait analysis is more and more widely, extensively used in orthopedic surgery and rehabilitation medicine abroad, while much less in China.OBJECTIVE: To study the parameters of time-distance, kinematics, kinetic and electromyography (EMG) in healthy subjects and patients with backbone, hip, knee or ankle joint diseases.DESIGN: Comparative observation and control study.PARTICIPANTS: From December 2004 to July 2005, 40 healthy subjects and 112 patients suffering from backbone and hip, knee, ankle joint disease were selected from the Department of Rehabilitative Medicine, Sixth People's Hospital Affiliated to Shanghai Jiao Tong University and analyzed by three dimensional gait analysis system (VICON 612 system made by Britain VICON Company). 112 patients including 42 males with the mean age of (46.2 ± 2.3) years and 70 females with the mean age (41.2 ± 3.5) years were screened by skilled clinicians after surgical and rehabilitative treatment.Among them there were 21 patients with cervical vertebra, 26 patients with prolapse of lumbar intervertebral disc and lumbar spinal stenosis. The number of hip, knee, ankle joint disease was 12, 34, 19 respectively. Total hip replacement was included in hip joint disease, anterior cruciate ligament (ACL) reconstruction was included in knee joint disease, talipes equinovarus was included in ankle joint disease. Meanwhile, 40 healthy subjects who were 20-40 years old, male or female, without any clinical symptom of backbone and limbs volunteered in the study.METHODS :Gait analysis were carried out on 40 healthy volunteers and 112 operational and rehabilitative treatment patients with spinal and lower limb diseases using VICON 612 system made by Britain VICON Company.MAIN OUTCOME MEASURES: The time-distance parameters (cadence, step length, walking speed), kinematics parameters (knee flexion/extension degree, hip flexion/extension degree, ankle dorsi/plantar degree), kinetic parameters (knee force in Z axis, hip force in Z axis, normalized force in Z axis) and EMG parameters (vastus lateralis SEMG) of lower limbs were examined.RESULTS: A total of 40 healthy subjects and 112 patients were involved in the analysis of results. ① Time-distance parameter: Cadence, as well as step length and walking speed of patients with backbone disease, patients with hip joint disease, patients with knee joint disease, and patients with ankle joint disease were lower than those of healthy subjects,and the difference between two groups was significant (P < 0.05-0.01). ② Kinematic and kinetic parameters of all joints in upper limbs: One year after left ACL knee reconstruction, the extension of left knee in initial contact phase was 9° less than that of right one and the stress in Z axis of left knee was much less than that of right one; One year after left THA,the flexion of left hip in initial contact phase was 8.5° less than that of right one, the extension of left hip in terminal stance phase was 3° less than that of right one, during stance phase the stress in Z axis of left hip was much less than that of right one; As to an infantile paralysis patient with talipes equinovarus, the dorsiflexion of left ankle in initial contact phase was 12° less than that of right one, the plantar flexion of left ankle in terminal stance phase was 5° less than that of right one. The stress in Z axis of left ankle during stance phase was much less than that of right one. However, the difference in range of motion and stress in Z axis was not significant between the left and right knee joint in healthy people. ③ One year after left total knee arthroplasty, the dynamic surface electromyogram signals of left vastus lateralis is much lower than that of right vastus lateralis in a gait cycle.CONCLUSION: 3D gait analysis enables tprovide objective basis for making operation scheme for orthopedic surgery and after-operation rehabilitation therapy, and assessing curative effect of rehabilitation therapy.
10.Study on Pharmacokinetics and Pharmacodynamics of Single-dose Intramuscularly Injected Methotrexate in the Treatment of Ectopic Pregnancy
Jianjian LIANG ; Juan WANG ; Jun LU
China Pharmacy 2005;0(22):-
OBJECTIVE:To study the pharmacokinetics and pharmacodynamics of single dose of intramuscularly injected methotrexate(MTX)in the treatment of ectopic pregnancy so as to provide theoretical bases for the choice dosage regimen.METHODS:Serum concentration of MTX in 8 cases with ectopic pregnancy were determined by fluorescence polarization immunoassay after injected i.m with single dose MTX(50mg/m2);The ?-HCG was monitored both before and after treatment and the lump sizes of the ectopic pregnancy were determined by B ultrasound.RESULTS:The pharmacokinetics of single dose of intramuscularly injected MTX conformed to two-compartment open model;Cmax occurred at 1.9h after drug taking with 2.31 ?mol/L;The time for the recovery of ?-HCG to normal was(24.8?10)days,the patency rate of oviducts of those who demanding procreation was 75%.CONCLUSION:Injection intramuscularly with single dose of MTX 50mg/m2 is effective in the treatment of ectopic pregnancy.