1.Association of Longitudinal Change in Fasting Blood Glucose with Risk of Cerebral Infarction in a Patients with Diabetes.
Tai Yang LUO ; Xuan DENG ; Xue Yu CHEN ; Yu He LIU ; Shuo Hua CHEN ; Hao Ran SUN ; Zi Wei YIN ; Shou Ling WU ; Yong ZHOU ; Xing Dong ZHENG
Biomedical and Environmental Sciences 2025;38(8):926-934
OBJECTIVE:
To investigate the association between long-term glycemic control and cerebral infarction risk in patients with diabetes through a large-scale cohort study.
METHODS:
This prospective, community-based cohort study included 12,054 patients with diabetes. From 2006 to 2012, 38,272 fasting blood glucose (FBG) measurements were obtained from these participants. FBG trajectory patterns were generated using latent mixture modelling. Cox proportional hazards models were applied to assess the subsequent risk of cerebral infarction associated with different FBG trajectory patterns.
RESULTS:
At baseline, the mean age of the participants was 55.2 years. Four distinct FBG trajectories were identified based on FBG concentrations and their changes over the 6-year follow-up period. After a median follow-up of 6.9 years, 786 cerebral infarction events were recorded. Different trajectory patterns were associated with significantly varied outcome risks (Log-Rank P < 0.001). Compared with the low-stability group, Hazard Ratio ( HR) adjusted for potential confounders were 1.37 for the moderate-increasing group, 1.23 for the elevated-decreasing group, and 2.08 for the elevated-stable group.
CONCLUSION
Sustained high FBG levels were found to play a critical role in the development of ischemic stroke among patients with diabetes. Controlling FBG levels may reduce the risk of cerebral infarction.
Humans
;
Cerebral Infarction/blood*
;
Middle Aged
;
Male
;
Female
;
Blood Glucose/analysis*
;
Fasting/blood*
;
Aged
;
Prospective Studies
;
Risk Factors
;
Diabetes Mellitus/blood*
;
Adult
;
Proportional Hazards Models
2.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
Humans
;
Female
;
Middle Aged
;
Aged
;
Male
;
Mitral Valve Insufficiency/etiology*
;
Retrospective Studies
;
East Asian People
;
Heart Valve Prosthesis Implantation
;
Treatment Outcome
;
China
;
Heart Failure/etiology*
;
Cardiac Catheterization
3.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
Humans
;
Female
;
Middle Aged
;
Aged
;
Male
;
Mitral Valve Insufficiency/etiology*
;
Retrospective Studies
;
East Asian People
;
Heart Valve Prosthesis Implantation
;
Treatment Outcome
;
China
;
Heart Failure/etiology*
;
Cardiac Catheterization
4.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
5.Correlation analysis of depression and social support level in cancer patients
Hong LUO ; Yong-Fang LIU ; Dao-Yan HU ; Jing WANG ; Shou-Feng HE ; Qin MA
Chinese Journal of Modern Nursing 2011;17(28):3389-3391
Objective To understand the status of depression and social support in cancer patients,to discuss the correlation between them,and to provide basis for improving their quality of life and mental states.Methods A questionnaire survey was conducted in 82 cancer patients with radiotherapy using Zung Depression Rating Scale (SDS) and Social Support Rating.Scale (SSRS).Results 50 cases (60.98% ) had depression symptoms ; Their SSRS score was ( 44.51 ± 4.02),with significant difference from the norm (34.56 ± 3.73 ) scores (t =22.425 ;P <0.01 ).Significant differences of social support and depression were found among different age groups and educational levels of cancer patients (P <0.01 ).Depression of the patients had a significant negative correlation with the level of social support,objective support,subjective support and utilization of support (r =-0.791,-0.855,-0.710,and -0.658;P<0.01).Conclusions Incidence of depression in cancer patients was high and the level of social support was fine.Depression is negatively related with social support.Nurses should pay attention to the role of social support systems in depression of cancer patients and use appropriate social support to improve the quality of life and psychological state of patients.
6.Development of the personalized criteria for microscopic review following four different series of hematology analyzer in a Chinese large scale hospital.
Wei CUI ; Wei WU ; Xin WANG ; Geng WANG ; Ying-Ying HAO ; Yu CHEN ; Dan LUO ; Wei-Ling SHOU ; Shuo ZHANG ; Xue-Fang XIANG ; Yong-Zhen SI ; Qian CHEN ; Hao CAI ; Tan LI ; Han SHEN ; Kun SHANG ; Yong-Qiang ZHANG
Chinese Medical Journal 2010;123(22):3231-3237
BACKGROUNDA generally accepted guideline ("41 rules") published by the International Consensus Group for Hematology Review (ICGHR) can not be suitable for all the laboratories because the facility type, laboratory requirements, sample volume, review rate, turn around time, instrument model and characters etc. are quite different from each other, which may cause a higher workload for microscopy review or lead to false or misleading results. Therefore, we decided to develop the personalized review criteria for 4 series of hematology analyzers in the same hospital, and describe all the implement procedures in detail.
METHODSThe total 1770 blood samples were collected from Peking Union Medical College Hospital. Referring to the suggested criteria by international consensus group for hematology review ("41 rules"), the personalized review criteria for 4 series of hematology analyzers including Siemens Advia 2120, Sysmex XE-2100, Sysmex XT-1800i and Sysmex XS-800i were established and validated by adjusting the rules in order to reduce the false positive rate and keep the false negative acceptable by clinical.
RESULTSUsing the "41 rules", high review rates of 37.94%, 35.56%, 33.44% and 37.94% were got respectively in Siemens Advia 2120, Sysmex XE-2100, Sysmex XT-1800i and Sysmex XS-800i. Three false positive rules mainly were observed in all of 4 analyzers: white blood cell < 3 × 10(9)/L or >30 × 10(9)/L, platelet < 100 × 10(9)/L or > 1000 × 10(9)/L and immature granulocyte. Specialized rules were observed in different series of analyzers, atypical/variant lymphs flag were found mainly in Sysmex XE-2100, Aniso-RBC were found mainly in Sysmex XT-1800i, flag of "immature granulocyte" mainly in Sysmex XS-800i, Micro-RBC, Macro-RBC and Aniso-RBC mainly in Siemens Advia 2120. Rules of immature granulocyte, blast, and NRBC flag would be mainly triggered by hematology malignant tumor. We could not delete these rules due to the risk of false negative of serious disease, other rules were deleted or revised. After continually optimizing to the rules, we finalized the criteria suitable for Siemens Advia 2120, Sysmex XE-2100, Sysmex XT-1800i and Sysmex XS-800i in our laboratory. The false negative rates were 2.94%, 2.86%, 3.10% and 2.78%, the review rates were 31.07%, 30.00%, 30.01% and 30.09%, and there was no hematology malignant tumor missed. Validated by 547 samples, the false negative rates of our optimized rules were 0.37%, 0.55%, 0.55%, and 0.91% respectively.
CONCLUSIONThe criteria can be based on the criteria established by International Consensus Group for Hematology Review but must be optimized according to the different requirements.
Adolescent ; Adult ; Aged ; Aged, 80 and over ; Child ; Child, Preschool ; China ; Female ; Hematologic Tests ; standards ; Hospitals ; standards ; Humans ; Male ; Middle Aged ; Young Adult
7.Identification of 2 strains of suspected Yersinia pestis isolated from Marmot,,himalayana in Dege County,Sichuan Province
Zhi-zhen, QI ; Dan-ba, LUOZHI ; Yong-jun, DUAN ; Min, LI ; Bai-zhong, CUI ; Rui-xia, DAI ; Jian-ping, FENG ; Cun-xiang, LI ; Shou-hong, YU ; Zu-yun, WANG ; Hu, WANG ; Xing, JIN ; Hai-hong, ZHAO ; You-quan, XIN ; Ling-ling, REN ; Qing-wen, ZHANG ; Rong-jie, WEI ; Li-xia, JIN ; Yong, JIG ; Hao-ming, XIONG ; Xiao-lin, LUO ; Sang-zhu, ZEREN ; Hong, WANG ; Shan-hu, ZHANG ; Wen-tao, GUO ; Xue, WANG ; Ze-li, DANBA ; Dan, WENG ; Dai-li, WANG
Chinese Journal of Endemiology 2009;28(1):48-53
Objective Throush identify biochemical characteristics and virulence factors of 2 strains suspected Yersinia pestis(Y.pestis)isolated from the dead Marmota himalayana(M.himalayana)to confirm the nature epidemic focus in Dege County,Sichuan Province.Methods Y.pestis was analyzed by specific staining and shape,culturing characteristics,splitting-test by bacteriophage,test of biochemical characteristics and glycolysis ability,virulence factors,virulence,nutritional requirement,plasmid,genetic test and genetic type. Results The tested strains were Gram staining bacilus.The main biochemical characteristics were Arabinose(+)、 Rhamnose(-),Maltose(+),Melibiose(-),Glycerol(+),Denitrification(+).The virulence factors with FI+.VW+, Pgm+,Pst I+;and with the common 6.0×106,45.0×106,65.0×106 plasmids,also with the virulence-relative plasmid gene.Both their absolutely lethal dose(LD100)in mice were 50 bacteria.The nutritional requirement appeared which were depended on Phenylalanine and Methionine.With the Genomovar 5 genotype characteristics of M.himalayana plague foci of Qinghai-Tibet plateau.The difference between tested strains and Yersinia pseudotubercuosis on the 3 different culture medium was obvious.The tested strains had a Y.pestis' specific 3a fragment,Pst I and FI-Ag,at 22 ℃,the strains could be split by bacteriophage completely.Conclusions According to the diagnostic criteria of plague in China,the 2 suspected strains isolated from Dege County,Sichuan Province ale confirmed as Y.pestis.both with powerful virulenceand with the characteristics of the Y.pestis of M.himahtyana in Qinghai-Tibet plateau plague natural focus.
8.Nedaplatin combined with tegafur in the treatment for advanced esophageal cancer.
Qing-Xia FAN ; Rui WANG ; Ping LU ; Yong-Fu ZHAO ; Tai-Ying LU ; Jian-Wei HAN ; Jun-Sheng WANG ; Su-Xia LUO ; Shou-Ping LU ; Gui-Ji WANG ; Li GENG ; Ming-Zhi ZHANG ; Zhi-Yong MA ; Min SONG ; Xin-Ai WU ; Xiao-Bing CHEN ; Zhi-Min JIAO ; Rui-Lin WANG
Chinese Journal of Oncology 2008;30(12):937-939
OBJECTIVETo investigate the efficacy and toxicity of nedaplatin combined with tegafur in the treatment for patients with advanced esophageal cancer.
METHODSAmong the 65 patients with advanced esophageal cancer, 27 had no history of prior chemotherapy and the other 38 had ever received postoperative adjuvant chemotherapy before. The median age of those cases was 58.0 years. Nedaplatin was given daily by intravenous infusion at a dose of 20 mg/m(2) for 2 hours and tegafur at a dose of 500 mg/m(2) for 8 hours on D1 approximately D5, every 21 days as a cycle.
RESULTS193 cycles of chemotherapy were accomplished in the 65 patients, and 63 patients were evaluable for response evaluation. Of 27 patients with no prior history of chemotherapy, 6 achieved complete response and 16 partial response, with a response rate (CR + PR) of 81.5%. Among the 36 patients who had ever received postoperative adjuvant chemotherapy, 6 obtained complete response and 10 partial response with a response rate (CR + PR) of 44.4%. The overall median time to tumor progression in this series was 5.6 months. The overall median actuarial survival was 9.3 months, and the one-year survival rate was 24.9%. Nausea and vomiting were the major toxicities, but were mild and well tolerable. Grade 3 to 4 neutropenia was only observed in two patients (3.2%).
CONCLUSIONThe regimen of nedaplatin combined with tegafur is effective and tolerable for the treatment of advanced esophageal cancer.
Adenocarcinoma ; drug therapy ; pathology ; Adult ; Aged ; Antineoplastic Combined Chemotherapy Protocols ; adverse effects ; therapeutic use ; Carcinoma, Squamous Cell ; drug therapy ; pathology ; Esophageal Neoplasms ; drug therapy ; pathology ; Female ; Follow-Up Studies ; Humans ; Male ; Middle Aged ; Nausea ; chemically induced ; Neoplasm Staging ; Neutropenia ; chemically induced ; Organoplatinum Compounds ; administration & dosage ; adverse effects ; Remission Induction ; Survival Rate ; Tegafur ; administration & dosage ; adverse effects ; Vomiting ; chemically induced
9.Levels of fluorine, arsenic, selenium In the hair of residents from fluorosis areas in Zhaotong City, ynnnan Province In 2006
Hui-jie, LI ; Kun-li, LUO ; Xiao-yong, LIAO ; Tong-bin, CHEN ; Wei-zhong, WANG ; Ming-hai, XIONG ; Wei, LI ; Ying-gui, LI ; Zu-shou, CHEN ; Guang-lai, ZHOU ; Qiao, CHEN
Chinese Journal of Endemiology 2008;27(4):434-436
Objective To assess the fluorine (F), arsenic (As) and selenium (Se) levels in hair of residents from the fluorosis area of Zhaotong and provide reference basis for the evaluation of the health status of populations in fluorosis areas as well as the prevention and control of fluorosis in Zhaotong. Methods Sixty-five hair samples were collected in fluorosis areas(Zhenxiong, Weixin County), including. 41 samples from 6 endemic townships and 24 samples from a non-endemic township. Fluorine content in hair was determined by combustion- hydrolysis-ion selective electrode method. Arsenic and selenium contents in hair were determined by atom- fluorescence method. Results The average contents of hair fluorine, arsenic and selenium contents were (15.1807±15.2397), (2.1806±1.9601), (2.3162±2.4535)mg/kg in the 41 patients with fluorosis and were (18.7703±17.1067), 0.3283±0.2466), (1.2805±0.6970) mg/kg in the 24 inhabitants (control). The difference of fluorine content in hair between patients in fluorosis and control inhabitants was not statistically significant (P 0.05), but the difference in arsenic and selenium content was statistically significant (P<0.05). Conclusions Mild arsenic pollution exists in Zhaotong fluorosis areas, which aggravates the prevalence of fluorosis. Food roasted with blended coal contains high fluorine. Meanwhile it may bring in the supplement of selenium for the inhabitants in Zhaotong fluorosis areas.
10.Surgical treatment of giant coronary artery aneurysm.
Dian-yuan LI ; Shang-shou HU ; Li-zhong SUN ; Yun-hu SONG ; Wei WANG ; Shi-wei PAN ; Hong ZHAO ; Guo-hua LUO ; Yong-min LIU ; Zhi-tao QI ; Tian-fu TAO
Chinese Journal of Surgery 2006;44(22):1535-1537
OBJECTIVETo discuss the clinical features and surgical treatments of giant coronary artery aneurysm (CAA).
METHODSFrom July 1996 to October 2004, 6 giant CAA patients were underwent surgery at Fuwai hospital. Three cases were underwent CAA resection, 2 concomitant coronary bypass, 3 reconstruction. The giant CAA was often combined with other cardiac diseases. Four cases underwent additional procedures of fistula closure, 3 aortic valve replacements, 2 aortoplasty and 1 thrombus cleaning at the same time.
RESULTSAll patients recovered uneventfully. The mean of cardiopulmonary bypass time was (144 +/- 26) min (range 67 to 207 min). Aortic cross clamping time was (104 +/- 21) min (range 56 to 172 min). Patients follow-up time occurred from 8 to 87 months (mean of 48 months). All patients were free of symptoms during follow-up. None of the patients died during the follow-up period and none of the CAA recurred.
CONCLUSIONSThe giant CAA is a serious cardiovascular disease, early diagnosis and surgical treatment are mandatory.
Adult ; Coronary Aneurysm ; pathology ; surgery ; Coronary Artery Bypass ; Coronary Vessels ; pathology ; surgery ; Female ; Follow-Up Studies ; Humans ; Male ; Middle Aged ; Surgical Procedures, Operative ; methods ; Treatment Outcome

Result Analysis
Print
Save
E-mail