1.Analytic Performance Evaluation of Blood Monitoring System G400 according to ISO 15197:2013.
Doheun CHUNG ; Byungkeun CHOI ; Byungwook YOO ; Chooyon CHO ; Sungho HONG ; Jungeun OH ; Yongjin CHO
Korean Journal of Health Promotion 2016;16(4):223-230
BACKGROUND: Self-monitoring of blood glucose is an important component of therapy for diabetes mellitus. The aim of this study was to evaluate the analytic performance evaluation of blood monitoring system G400 according to ISO 15197:2013. METHODS: We evaluated the G400 according to the ISO 15197:2013 guideline, we measured precision, accuracy, interference of hematocrit and interfering substances, user performance. RESULTS: Repeatability and intermediate precision of G400 showed standard deviation 2.7–3.8 mg/dL, 2.4–3.6 mg/dL and coefficient of variation 1.9-2.9% and 1.7–3.7%, respectively. Accuracy measured 98–98.5%, satisfied acceptable criteria. Error grid analysis showed that all results of this study were in zone A. Hematocrit between 20% to 60% did not cause interference. Three of 24 interfering substances were not acceptable criteria, and dose-response evaluation was needed. CONCLUSIONS: This study showed that G400 was considered reliable results satisfying the ISO 15197:2013 criteria
Blood Glucose
;
Blood Glucose Self-Monitoring
;
Diabetes Mellitus
;
Hematocrit
3.Technical Difficulties in the Implementation of the Continuous Glucose Monitoring System.
Yacheng FU ; Changyun QUAN ; Lixia LIU ; Wei ZHANG
Chinese Journal of Medical Instrumentation 2022;46(4):422-427
The continuous glucose monitoring system (CGMS) has been clinically applied to monitor the dynamic change of the subcutaneous interstitial glucose concentration which is a function of the blood glucose level by glucose sensors. It can track blood glucose levels all day along, and thus provide comprehensive and reliable information about blood glucose dynamics. The clinical application of CGMS enables monitoring of blood glucose fluctuations and the discovery of hidden hyperglycemia and hypoglycemia that are difficult to be detected by traditional methods. As a CGMS needs to work subcutaneously for a long time, a series of factors such as biocompatibility, enzyme inactivation, oxygen deficiency, foreign body reaction, implant size, electrode flexibility, error correction, comfort, device toxicity, electrical safety, et al. should be considered beforehand. The study focused on the difficulties in the technology, and compared the products of Abbott, Medtronic and DexCom, then summarized their cutting-edge. Finally, this study expounded some key technologies in dynamic blood glucose monitoring and therefore can be utilized as a reference for the development of CGMS.
Blood Glucose
;
Blood Glucose Self-Monitoring/methods*
;
Humans
;
Hyperglycemia
;
Hypoglycemia
;
Monitoring, Ambulatory/methods*
;
Monitoring, Physiologic
4.Research Progress on Enzyme-free Blood Glucose Sensor.
Jin-Jiang JIN ; Ju-Chao ZOU ; Hong LIU ; Yong-Hua CHU ; Guo-Hua HUI
Chinese Journal of Medical Instrumentation 2022;46(3):296-301
Blood glucose monitoring is of great significance to diabetic patients, and the development of rapid, accurate and real-time glucose detection technology has become a research hotspot nowadays. This study introduces the concept and classification of the enzyme-free glucose sensor, expounds enzymefree glucose sensor electrode characterization methods and the application progress of different materials in enzyme-free blood glucose sensors. Meanwhile, some problems of enzyme-free glucose sensor existing in the current research and its future application prospects also will be discussed.
Blood Glucose
;
Blood Glucose Self-Monitoring
;
Electrodes
;
Glucose
;
Humans
;
Monitoring, Physiologic
5.Research progress on minimally invasive and non-invasive blood glucose detection methods.
Xinyu GAO ; Zekai XU ; Liqun CHEN
Journal of Biomedical Engineering 2023;40(2):365-372
Blood glucose monitoring has become the weakest point in the overall management of diabetes in China. Long-term monitoring of blood glucose levels in diabetic patients has become an important means of controlling the development of diabetes and its complications, so that technological innovations in blood glucose testing methods have far-reaching implications for accurate blood glucose testing. This article discusses the basic principles of minimally invasive and non-invasive blood glucose testing assays, including urine glucose assays, tear assays, methods of extravasation of tissue fluid, and optical detection methods, etc., focuses on the advantages of minimally invasive and non-invasive blood glucose testing methods and the latest relevant results, and summarizes the current problems of various testing methods and prospects for future development trends.
Humans
;
Blood Glucose
;
Blood Glucose Self-Monitoring/methods*
;
Diabetes Mellitus/diagnosis*
;
Monitoring, Physiologic/methods*
;
Tears
6.Mediating effect of self-efficacy on self-management ability and self-management behavior in patients with type 2 diabetes mellitus.
Xiao Yue ZHANG ; Yu Xin LIN ; Ying JIANG ; Lan Chao ZHANG ; Mang Yan DONG ; Hai Yi CHI ; Hao Yu DONG ; Li Jun MA ; Zhi Jing LI ; Chun CHANG
Journal of Peking University(Health Sciences) 2023;55(3):450-455
OBJECTIVE:
To investigate the mechanism of self-efficacy between self-management ability and self-management behavior and its differences among patients with different disease courses through mediation tests.
METHODS:
In the study, 489 patients with type 2 diabetes who attended the endocrinology departments of four hospitals in Shanxi Province and Inner Mongolia Autonomous Region from July to September 2022 were enrolled as the study population. They were investigated by General Information Questionnaire, Diabetes Self-Management Scale, Chinese version of Diabetes Empowerment Simplified Scale, and Diabetes Self-Efficacy Scale. Mediation analyses were performed using the linear regression model, Sobel test, and Bootstrap test in the software Stata version 15.0 and divided the patients into different disease course groups for subgroup analysis according to whether the disease course was > 5 years.
RESULTS:
In this study, the score of self-management behavior in the patients with type 2 diabetes was 6.16±1.41, the score of self-management ability was 3.99±0.74, and the score of self-efficacy was 7.05±1.90. The results of the study showed that self-efficacy was positively correlated with self-management ability (r=0.33) as well as self-management behavior (r=0.47) in the patients with type 2 diabetes (P < 0.01). The mediating effect of self-efficacy accounted for 38.28% of the total effect of self-management ability on self-management behaviors and was higher in the behaviors of blood glucose monitoring (43.45%) and diet control (52.63%). The mediating effect of self-efficacy accounted for approximately 40.99% of the total effect for the patients with disease course ≤ 5 years, while for the patients with disease course > 5 years, the mediating effect accounted for 39.20% of the total effect.
CONCLUSION
Self-efficacy enhanced the effect of self-management ability on the behavior of the patients with type 2 diabetes, and this positive effect was more significant for the patients with shorter disease course. Targeted health education should be carried out to enhance patients' self-efficacy and self-management ability according to their disease characteristics, to stimulate their inner action, to promote the development of their self-management behaviors, and to form a more stable and long-term mechanism for disease management.
Humans
;
Diabetes Mellitus, Type 2/therapy*
;
Self Efficacy
;
Self-Management
;
Blood Glucose Self-Monitoring
;
Blood Glucose
;
Self Care
7.Development of a portable glucose meter based on PIC microcomputer.
Chinese Journal of Medical Instrumentation 2006;30(1):29-32
A portable glucose meter based on PIC microcomputer with data storage, analysis and historical data curve display functions, is presented. The concentration of blood glucose is detected with a glucose oxidase electrode. Test records may be stored and historic data can be displayed on the LCD with a fitting curve.
Blood Glucose Self-Monitoring
;
instrumentation
;
Computer-Aided Design
8.Effectiveness of smartphone applications in achieving glycemic control among adult diabetic patients: A meta-analysis.
Eron Allen C. Tan ; Janella Jillian G. Abella ; Marie Ruth A. Echavez
The Filipino Family Physician 2024;62(1):145-154
BACKGROUND
Diabetes Mellitus Type 2 is a significant global health issue with a high prevalence in the Philippines. Managing this condition effectively is crucial, and digital technologies, particularly smartphone (mHealth) applications, have emerged as a potential tool in diabetes self-management.
OBJECTIVEThis study evaluated the effectiveness of smartphone (mHealth) application use in achieving glycemic control among adults with Type 2 Diabetes Mellitus, focusing on HbA1c levels and medication adherence.
METHODThis systematic review and meta-analysis, adhering to PRISMA guidelines, analyzed randomized controlled trials from databases like PubMed and Embase, comparing interventions using mHealth applications with standard care. The primary measures were HbA1c levels and medication adherence.
RESULTSTen studies involving 20,984 participants were included in the meta-analysis. Using mHealth applications led to an average HbA1c reduction of 0.36%, indicating improved glycemic control. There was considerable heterogeneity (I2 = 91%) because of the clinical and methodological diversity of the included studies. Subgroup analysis showed that the younger and older age groups, shorter and longer T2DM duration, and lower and higher HbA1c baseline benefited from its use. Sensitivity analysis still showed high heterogeneity (95%-97%), reflecting clinical diversity. A narrative analysis of two studies highlighted the utility of mHealth applications in tracking diet, physical activity, and vital stats, aiding medication adherence through reminders and data sharing with healthcare providers.
CONCLUSION/RECOMMENDATIONSThis systematic review and meta-analysis showed the effectiveness of mHealth application use in achieving glycemic control among adults with Type 2 Diabetes Mellitus by improving HbA1c levels and medication adherence. Integrating mHealth applications as adjuncts in family and community medicine as part of personalized care for managing type 2 diabetes in the Philippines can help achieve glycemic control and medication adherence. Future studies should focus on longitudinal assessments, exploring cultural and linguistic factors in the Filipino context to optimize diabetes care within this specialized medical framework.
Blood Glucose Self-monitoring ; Mobile Applications ; Diabetes Mellitus
9.Clinical Usefulness of Glucose Testing from the Forearm in Diabetic Patients.
Sang Wook LEE ; Suk CHON ; Seungjoon OH ; Jeong taek WOO ; Sung Woon KIM ; Jin Woo KIM ; Young Seol KIM ; Jeong Ryung PAENG ; Gwanpyo KOH ; Hak Hyun NAM
Journal of Korean Society of Endocrinology 2006;21(4):281-289
BACKGROUND: Self monitoring of blood glucose plays an important role in the management of diabetes. However, traditional finger prick testing causes pain and so compliance with self monitoring of blood glucose is usually poor. Using an alternative site for sampling may reduce the level of pain and be beneficial for improving the compliance of diabetic patients. We evaluated the accuracy and acceptability of blood glucose testing from the forearm by analyzing the performance of the CareSens(R) (i-Sens, Inc. Korea) device for diabetic patients. METHODS: We measured the glucose level at the forearm by use of CareLance(R) (vaccum assisted lancing device) and also at the finger tip simultaneously by use of the CareSens(R) device at fasting and postprandial 2 hours, respectively. At the same time, the glucose levels of venous samples were checked by the laboratory method (BIOSEN 5030, EKF, Germany) and compared with those glucose level measured by the CareSens(R) device. We also checked the ease of use of the CareLance(R) and the associated pain of the patients by means of a visual analogue scale (VAS) at the time of blood sampling. RESULTS: The glucose level obtained from the forearm and finger tip correlated well with that from the laboratory method, respectively. Error grid analysis showed that 100% of the measurements were clinically acceptable; forearm blood glucose testing by use of CareLance(R) was less painful and it was as easy to use as the finger prick (P < 0.05 and P = 0.04, respectively). CONCLUSION: Forearm testing is an acceptable alternative to finger prick testing for measuring blood glucose in diabetic patients.
Blood Glucose
;
Blood Glucose Self-Monitoring
;
Compliance
;
Diabetes Mellitus
;
Fasting
;
Fingers
;
Forearm*
;
Glucose*
;
Humans
10.Clinical Usefulness of Glucose Testing from the Forearm in Diabetic Patients.
Sang Wook LEE ; Suk CHON ; Seungjoon OH ; Jeong taek WOO ; Sung Woon KIM ; Jin Woo KIM ; Young Seol KIM ; Jeong Ryung PAENG ; Gwanpyo KOH ; Hak Hyun NAM
Journal of Korean Society of Endocrinology 2006;21(4):281-289
BACKGROUND: Self monitoring of blood glucose plays an important role in the management of diabetes. However, traditional finger prick testing causes pain and so compliance with self monitoring of blood glucose is usually poor. Using an alternative site for sampling may reduce the level of pain and be beneficial for improving the compliance of diabetic patients. We evaluated the accuracy and acceptability of blood glucose testing from the forearm by analyzing the performance of the CareSens(R) (i-Sens, Inc. Korea) device for diabetic patients. METHODS: We measured the glucose level at the forearm by use of CareLance(R) (vaccum assisted lancing device) and also at the finger tip simultaneously by use of the CareSens(R) device at fasting and postprandial 2 hours, respectively. At the same time, the glucose levels of venous samples were checked by the laboratory method (BIOSEN 5030, EKF, Germany) and compared with those glucose level measured by the CareSens(R) device. We also checked the ease of use of the CareLance(R) and the associated pain of the patients by means of a visual analogue scale (VAS) at the time of blood sampling. RESULTS: The glucose level obtained from the forearm and finger tip correlated well with that from the laboratory method, respectively. Error grid analysis showed that 100% of the measurements were clinically acceptable; forearm blood glucose testing by use of CareLance(R) was less painful and it was as easy to use as the finger prick (P < 0.05 and P = 0.04, respectively). CONCLUSION: Forearm testing is an acceptable alternative to finger prick testing for measuring blood glucose in diabetic patients.
Blood Glucose
;
Blood Glucose Self-Monitoring
;
Compliance
;
Diabetes Mellitus
;
Fasting
;
Fingers
;
Forearm*
;
Glucose*
;
Humans