1.Expression of neuroglobulin during the process of brain edema induced by endotoxin in rats
Chao LIU ; Shanquan SUN ; Mei YANG ; Hai CHEN
Medical Journal of Chinese People's Liberation Army 2001;0(09):-
Objective To study the expression of neuroglobulin(Ngb) in cortex of frontal lobe,hippocampus,cerebrospinal fluid(CSF) and plasma of rats during the process of brain edema induced by endotoxin(LPS).Methods Seventy SD rats were randomly divided into the control group(n=10) and the LPS groups(10 each at six time points).An intraventricular injection of LPS(0.1mg/kg,0.2ml) was given to rats in LPS groups,while the same amount of normal saline was given in control group.The plasma,CSF,hippocampus and the cortex of frontal lobe of rats were collected 3,6,12,24,48 and 72 hours after the injection.Ngb was detected by ELISA,Western blotting and immunohistochemical(IHC) method.The brain water content was measured by wet/dry method.The swelling of organelles in hippocampus and the cortex of frontal lobe were observed by transmission electron microscopy(TEM).Results The brain water content was significantly higher in LPS groups than in control group(P
2.Preparation Technology of Chinese Traditional Medicine Seborrhea Liniment
Yanfu DONG ; Mei QI ; Lilun YANG ; Lijun YU ; Hai JIA
China Pharmacy 2007;0(33):-
OBJECTIVE:To study the preparation technology of Chinese traditional medicine Seborrhea liniment.METHODS:The preparation technology of Seborrhea liniment was optimized by orthogonal experiment design L9(34)using 60% alcohol as solvent with the content of Berberine hydrochloride as index for evaluation and with the extraction method,extraction time,amount of solvent and number of extraction times as factors.RESULTS:The optimum preparation technical conditions were as follows:by impregnating method,the extraction time was 48 h using 1 500 mL alcohol and the extraction frequency was 2 times.CONCLUSION:The preparation technology of Chinese traditional medicine Seborrhea liniment is stable and feasible,and it serves as a theoretical basis for the industrial production.
4.The evaluation of efflux transporter model based on RNA interference technology in vitro.
Ling-lei KONG ; Hai-ying YANG ; Mei YUAN ; Xiao-mei ZHUANG ; Hua LI
Acta Pharmaceutica Sinica 2015;50(9):1122-1127
In the present study, the specifically knockdown models of P-gp or MRP2 were constructed by using a series of chemically synthesized small interfering RNA (siRNA) in vitro. The expression of P-gp and MRP2 was measured by real-time PCR and Western blot, and the function was evaluated by applying P-gp and MRP2 substrate, rhodamine and methotrexate. The results showed that MRP2 siRNA-3 or P-gp siRNA-2 significantly decreased the mRNA expression of MRP2 or P-gp, the inhibition ratio was 68% or 84%; MRP2 siRNA-3 or P-gp siRNA-2 at a dose of 80 nmol x L(-1) significantly reduced the protein expression of MRP2 or P-gp at 48 h after treatment, the inhibition ratio was 62% or 70%. Meanwhile, other transporters were not influenced by siRNA. When pretreatment with MRP2 siRNA-3 or P-gp siRNA-2, the efflux of methotrexate or rhodamine decreased significantly and the intra-cellular concentration increased. The results suggested that chemically synthesized siRNA could significantly inhibit the expression and function of MRP2 and P-gp, and the model of RNAi in vitro could be used to evaluate the role of efflux transporters in transportation of drugs.
ATP-Binding Cassette, Sub-Family B, Member 1
;
genetics
;
Gene Knockdown Techniques
;
Multidrug Resistance-Associated Proteins
;
genetics
;
RNA Interference
;
RNA, Small Interfering
;
Real-Time Polymerase Chain Reaction
5.Effect of xin an granule on electrophysiological response of ventricular muscle cell in rabbits with ischemia.
Si-jin YANG ; Mei-juan CHEN ; Hai-tao YANG
Chinese Journal of Integrated Traditional and Western Medicine 2006;26 Suppl():1-3
OBJECTIVETo investigate the electrophysiological effect of Xin' an granule (XAG) on ventricular muscle cell in ischemic rabbits.
METHODSA total of 48 rabbits were divided into the normal group and the ischemic group, and then subdivided into three groups, the control group, the high and low-dose XAG groups, 8 in each group. Rabbits in the low-dose XAG group and the high-dose XAG group were gastrogavaged XAG at the daily dose of 0. 85 g/kg and 3.40 g/kg, while the others in the control group were given the equal dosage of normal saline. All the rabbits were treated three times per day for successive 10 days. The rabbit model of ischemia was established by intravenous injected with 2. 5 U/kg posterior pituitary injection. Five minutes later, the monophasic action potential (MAP) and electrocardiogram (ECG) of each rabbit in the different groups were recorded and compared.
RESULTS(1) To normal rabbits, XAG could significantly shorten the action 50% and 90% potential duration (APD)50 and APD90 of ventricular muscle cell (P < 0.05 ), and high-dose of XAG could significantly increased the Vmax of MAP(P <0. 05). (2) While to ischemic rabbits, XAG could significantly prolong APD50 and APD90, and significantly increased the action potential amplitude (APA) and Vmax of MAP (P < 0. 05).
CONCLUSION(1) XAG can significantly shorten APD50 and APD90 of ventricular muscle cell, and high-dose XAG significantly increase the Vmax of MAP of normal rabbits. (2) XAG can delay and alleviate the manifestation characteristics of action potential of ventricular muscle cell during ischemia.
Action Potentials ; drug effects ; Animals ; Disease Models, Animal ; Dose-Response Relationship, Drug ; Electrocardiography ; Heart Ventricles ; cytology ; drug effects ; Medicine, Chinese Traditional ; Myocardial Ischemia ; physiopathology ; Myocytes, Cardiac ; drug effects ; physiology ; Rabbits
6.The immunoregulatory effects of bone marrow mesenchymal stem cells on allogeneic peripheral B lymphocyte
Lingqi WU ; Hai BAI ; Cunbang WANG ; Xiaoliang YANG ; Qiang ZHAO ; Yiwu YANG ; Mei LIN
Chinese Journal of Microbiology and Immunology 2008;28(6):486-491
Objective To study the immunoregulatory effects of bone marrow mesenchymal stem cells (MSC) on allogeneic peripheral B lymphocytes in vitro. Methods MSCs were isolated and cultured from bone marrow by gradient centrifugation. Mononuclear cells were isolated routinely from peripheral blood, then monocytes were eliminated by L-leucine methy ester method. Remained T lymphocytes were eliminated by AET-SRBC rosette method. The action of MSCs and its supernatant on B lymphocytes proliferation in the presence of anti-human IgM goat antibodies (anti-IgM) was investigated by MTT. The IgG, IgM in the supernatant were detected by ELISA. The percent of apoptosis B lymphocytes, co-cultured with MSCs for 24 or 48h, was assayed by FACS. Results MSCs and its supernatant inhibited B lymphocytes proliferation and Ig secretion. The inhibitory effect depended on the amount of MSCs and condition of its supernatant. The date of FACS indicated that the apoptosis ratio of B lymphocytes, co-cultured with MSCs for different times, were non-significant. The inhibitory effect of MSCs on B lymphocytes was temporary and reversible. Conclusion MSCs have immunoregulatory effects on B lymphocytes, and its mechanisms are complex, not only correlating with the concentration of MSCs but also the action between cells and the secretory cytokine of MSCs.
7.Research progress of Chinese herbal medicine raw materials in cosmetics.
Yan-jun XIE ; Wei-jun KONG ; Mei-hua YANG ; Shi-hai YANG
China Journal of Chinese Materia Medica 2015;40(20):3925-3931
Advocating green, nature, environmental protection, safety and the pursuit of efficacy are the trends of cosmetics in the world. In recent years, more and more Chinese herbal extracts with mild, high safety and small irritation are applied to cosmetics as the natural additives. This has become a new hot spot. The recent application advances of Chinese medicine raw materials in cosmetics are overviewed according to their main functions. This review will provide useful references for the future development and application of Chinese medicinal herbs cosmetics.
Animals
;
Biomedical Research
;
trends
;
Consumer Product Safety
;
Cosmetics
;
analysis
;
Drugs, Chinese Herbal
;
analysis
;
Humans
8.Relation Between Hemoglobin and Blood Pressure
Hai-Lan ZHONG ; Xin-Zheng LU ; Xiu-Mei CHEN ; Xiao-Hui YANG ; Hai-Feng ZHANG ; Ke-Jiang CAO ; Jun HUANG ;
Chinese Journal of Hypertension 2006;0(12):-
Objective To study the relationship between peripheral blood hemoglobin (HB) and blood pres- sure.Methods We performed a cross-sectional analysis in 1153 subjects aged 29-83 years.Waist circumfer- ence,HB,blood pressure,high-density lipoprotein cholesterol(HDL-C),low-density lipoprotein cholesterol(LDL- C),triglycerides (TG),total cholesterol (TC) were determined.Results ①With the increasing of blood pres- sure,HB had a clearly increasing trend (HB,normotensive:137.5?14.7 vs prehypertension:143.4?14.4 vs hy- pertension:144.3?13.8 g/L,P
9.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
10.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.