1.Operative cooperation of 1aparoscopic adjustable gastric banding placation to reduce weight
Bin WANG ; Dongling LI ; Ziyu XIE
Modern Clinical Nursing 2014;(10):36-38,39
ObjectiveTo summarize the intraoperative nursing of patients undergoing aparoscopic adjustable gastric banding placation to reduce weight and improve the efficiency of operative cooperation.Method The clinical data on the intraoperative nursing of 9 patients undergoing laparoscopic adjustable gastric banding placation were retrospectively reviewed and analyzed.Result All patients lived through the successful operations and the postoperative rehabilitation were in good condition without postoperative complications and sequelae.Conclusion Full preoperative operation,familiarity with the operative procedures,close cooperation with surgeons are key to smooth performance of the operation and assurance of patient’s safety.
2.Regulatory effects of total triterpenoid of Prunella vulgarisL. on activities of ERK and TGF-β1/Smad signaling pathway in protecting hepatic fibrosis in rats
Shengpeng ZHANG ; Yong HE ; Tao XU ; Cheng HUANG ; Jiali XIE ; Ziyu DENG ; Jun LI
Chinese Pharmacological Bulletin 2015;(2):261-265,266
Aim To investigate the protective effects of total triterpenoid from Prunella vulgaris L. ( TTP) on CCl4-induced hepatic fibrosis in rats and its mecha-nism. Methods Rat liver fibrosis was induced by 50% CCl4 twice a week for 12 weeks. From the 5th week, all the therapeutic groups were treated with the TTP(25, 50, 100 mg·kg-1 ) and the colchicine (0. 1 mg· kg-1 ) respectively once a day for 8 weeks. At the end of the twelfth week, the levels of ALT, AST, HA, PCⅢ, CⅣ, MDA, SOD, GSH-Px, Hyp were measured . HE and Masson staining were used to evalu-late the degree of hepatic fibrosis. The mRNA expres-sion ofα-SMA, procollagen I, Smad2, Smad3, Smad7 in liver was detected by RT-PCR, and the p-ERK pro-tein expression was evaluated by Western blot. Results Compared with the model group, TTP(25, 50, 100 mg·kg-1 ) not only reduced serum content of ALT, AST, HA, PCⅢ, CⅣand Hyp, MDA in liver tissue, improved the morphologic changes of hepatic fibrosis, but also increased SOD and GSH-Px activity. Moreo-ver, it decreased the α-SMA, procollagen I, Smad2, Smad3 mRNA expression and increased Smad7 mRNA expression in liver tissues obviously. Furthermore, TTP reduced the protein expression of p-ERK. Conclusions TTP can protect rats from CCl4-induced liver fibro-sis. The mechanism of this process may involve inhibi-ting the expression of p-ERK and interference with TGF-β1/Smad signal transduction pathway.
3.Analyze 11425 cases of congenital malformations for birth defects intervention
Ziyu WU ; Yanxia LIANG ; Liqun XIE ; Ruiyu HUANG ; Baolin CHEN ; Qiuyuan HE
The Journal of Practical Medicine 2017;33(10):1694-1696
Objective To collect the incidence and distribution of congenital malformations ,find monitor-ing and preventive measures,to provide a basis for reasonable allocation of health resources for clinical depart-ments. Methods According to The International Classification of Diseases(ICD-10)chapter 17 encoding table, we analyze our hospital′s cases from January 2003 to December 2010 in order to understand the incidence of con-genital malformations of every system. Results Top five diseases are:cleft palate deformity ,genital malforma-tion,congenital heart disease and digestive system malformation in equal third place,and facial deformity. The age ranged from 1d to 35 y,men more than women. Conclusions The key to effectively reduce the incidence of con-genital malformation is strictly implement the three-level intervention mechanism. Prevention ,early detection and early treatment will improve the patient′s quality of life.
4.Emergency bedside-echocardiography in neonatal intensive care unit
Ziyu TAO ; Lijian XIE ; Jie SHEN ; Tingting XIAO ; Yongwei ZHANG ; Rufang ZHANG ; Gang QIU ; Xiaohui GONG ; Hailan LU
Chinese Journal of Perinatal Medicine 2012;(12):727-731
Objective To evaluate the clinical value of emergency bedside-echocardiography in neonatal intensive care unit.Methods Six hundred and sixty-eight infants with cardiac pathological murmurs,cyanosis and shortness of breath were detected by emergency bedside echocardiography (Sonosite Micromax 1 portable ultrasound or Philips iE33 ultrasonic systems) during January 2007 to July 2011.The accuracy of emergency bedside-echocardiography in the diagnosis of neonatal heart diseases was evaluated according to the results of surgical exploration.Results Among 668 enrolled neonates with the mean age of (7.2±1.3) d,there were 347 males and 321 females,and 309 term infants [mean gestational age (39.1±0.6) weeks (37.0~42.1 weeks)] and 359 premature infants [mean gestational age (33.7±0.91) weeks (28.9~36.9 weeks)].Totally,507 cases were found cardiac abnormality by emergency bedside-echocardiography,including 268 cases of patent ductus arteriosus (232 premature and 36 term infants),115 congenital heart disease,99 persistent fetal circulation and 25 arrythmia.Surgeries were performed on 54 infants and invasive therapy was performed on one infant,and none of them received CT,magnetic resonance imaging or invasive examinations before operation; among which,51 surgeries successed and 4 infants died.Other 452 infants were treated with medications,392 infants recovered and discharged,26 infants did not recover,14 cases died and 20 cases left the hospital before recovery.The accuracy rate of Micromax 1 portable ultrasound in diagnosing congenital heart diseases was 94.5% (52/55),while 96.4 % (53/55) for philips iE33 ultrasonic systems.Conclusions Emergency bedside-echocardiography could provide instant and valuable information of cardiovascular system,which would be helpful in making quick clinical decisions.
5.Determination of serum glucose by isotope dilution liquid chromatography tandem mass spectrometry
Tianjiao ZHANG ; Chuanbao ZHANG ; Jiangtao ZHANG ; Weiyan ZHOU ; Haijian ZHAO ; Ying YAN ; Cuihua HU ; Donghuan WANG ; Jing WANG ; Jiehong XIE ; Rong MA ; Ziyu SHEN ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2010;33(1):75-80
Objective To develop a candidate reference method for the measurement of serum glucose based on isotope dilution liquid chromatography tandem mass spectrometry(ID-LC/MS/MS)Methods An internal standard [~(13)C_6]glucose was added to serum samples and equilibrated with endogenous glucose.Serum proteins were removed by a precipitation with anhydrous ethanol.Serum glucose and the internal standard were then reacted with 1-phenyl-3-methyl-5-pyrazolone and the formed derivatives were analyzed by liquid chromatography tandem mass spectrometry with multiple reaction monitoring(MRM).The method was calibrated with bracketing calibrators and serum glucose concentrations were calculated by comparing the peak area ratios of samples with that of the calibrators.Results The within-run,between-run and total coefficients of variation averaged 0.36%,0.47%and 0.61%,respectively.The analytical recoveries ranged from 99.0% to 100.9%.Results of analyzing the certified reference material SRM 965a showed an average biases of-0.20%.Conclusions An ID-LC/MS/MS method for measuring serum glucose has been developed.The method is highly precise and accurate and may be used as a candidate reference method.
6.Determination of serum creatinine by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method
Tianjiao ZHANG ; Haijian ZHAO ; Chuanbao ZHANG ; Jiangtao ZHANG ; Cuihua HU ; Ying YAN ; Donghuan WANG ; Jing WANG ; Jiehong XIE ; Rong MA ; Ziyu SHEN ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2009;32(5):509-514
Objective To develop a candidate reference method for the measurement of creatinine in human serum based on isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS). Methods An isotopically labeled internal standard [<'2>H<,3>] creatinine was added to the serum sample and equilibrated with the endogenous creatinine. The samples were treated with anhydrous ethanol to remove proteins by precipitation. After being washed with chloroform for further clean-up, the samples were analyzed by LC/MS/MS. Serum creatinine was quantified by a bracketing calibration. Results The within-run, between-run and total coefficients of variation ranged from 0.52% to 0.61%, 0.11% to 0.59% and 0.61% to 0.83%, and the averages were 0.57%, 0.43% and 0.73%, respectively. The analytical recoveries ranged from 99.09% to 101.13% with an average of 100.3%.The results of analyzing the certified reference material SRM 909b (Level Ⅰ and Ⅱ) and SRM 967b showed biases of less than 0.4%. Conclusions An ID-LC/MS/MS method for measuring serum creatinine has been developed. The method is highly precise and accurate and may be used as a candidate reference method for serum creatinine measurements.
7.Determination of serum urea by isotope dilution gas chromatography mass spectrometry:a candidate reference method
Tianjiao ZHANG ; Jiangtao ZHANG ; Chuanbao ZHANG ; Haijian ZHAO ; Jing WANG ; Jiehong XIE ; Donghuan WANG ; Cuihua HU ; Rong MA ; Ziyu SHEN ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2008;31(5):536-539
Objective To develop a candidate reference method for the measurement of urea in human serum based on isotope dilution/gas chromatography/mass spectrometry.Methods [13C,15N2]Urea used as internal standard Was added to the serum sample and equilibrated with endogenous nonlabeled urea.The serum samples were treated with anhydrous ethanol to emove proteins by precipitation.The serum urea and labeled urea were converted into a trimethylsilyl derivative of 2-hydroxypyrimidine and analyzed by gas chromatography/mass spectrometry system with selected ion monitoring.The concentration of serum ureaWas calculated by the theory of bracketing method.Results The average value of within-run oefficient of vailation(CV),between-run CV and total CV of the procedure were 0.38%(ranged from 0.12%to 0.47%),O.62%(ranged form 0.49% to 0.87%)and 0.73%(ranged from 0.51% to 0.93%).Respectively.The analytical recoveries ranged from 99.37% to 100.95%.The resuhs of analyzing the certified refefence material SRM909b(Level Ⅰand Ⅱ)showed a bias less than 0.2%.Conclusion The procedure for measuring urea in serum is a highly accurate and precise method and can be used as a candidate reference method for serum urea assays.
8.Evaluation of matrix effects in serum urea measurements
Haijian ZHAO ; Tianjiao ZHANG ; Chuanbao ZHANG ; Weiyan ZHOU ; Jiangtao ZHANG ; Jing WANG ; Jiehong XIE ; Rong MA ; Cuihua HU ; Donghuan WANG ; Ziyu SHEN ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2008;31(3):270-275
Objective To evaluate the matrix effects in serum urea measurements of external quality assessment(EQA)materials and commercial reference materials(calibrators or controls)on enzymatic methods and to verify the trueness of the enzymatic methods.Methods The Clinical and Laboratory Stadards Institute(CLSI)EP 14-A2 protocol was used for the evaluation of matrix effect.An isotope dilution gas chromatography mass spectrometry method was used as the comparative method.Twenty five fresh patient serum samples,15 EQA materials and 13 calibrators or controls were analyzed with 7 enzymatic methods (evaluated methods)and the comparative method and results were processed according to the protocol. The trueness of the evaluated methods were also assessed by comparing the fresh sample results obtained with the evaluated and comparative methods.Results Eight of 15 EQA materials and 3 of 13 calibrators or controls showed no matrix effects on all the 7 routine methods.One processed sample showed matrix effect on all the routine methods.Method dependent matrix effects of other materials were observed on other materials.Calibration biases were also observed on some enzymatic methods.Conclusions Matrix effects and calibration bias have been observed in serum urea measurements.Continued efforts are needed for improving the accuracy and the comparability of serum urea measurements.
9.Determination of serum cholesterol by isotope dilution gas chromatography mass spectrometry
Jiang-Tao ZHANG ; Cui-Hua HU ; Chuan-Bao ZHANG ; Hai-Jian ZHAO ; Rong MA ; Jie-Hong XIE ; Jing WANG ; Jun DONG ; Shu WANG ; Ziyu SHEN ; Wenxiang CHEN ;
Chinese Journal of Laboratory Medicine 2001;0(03):-
Objective To develop a new isotope dilution gas chromatography mass spectrometry method (ID/GC/MS) for the measurement of serum cholesterol.Methods Serum was mixed with an isotope labeled internal standard ([3,4-~(13)C]-cholesterol) and treated with alcoholic sodium hydroxide to hydrolyze cholesterol ester to cholesterol.Cholesterol and internal standard was extracted and derived by N, O-Bis(trimethylsilyl) trifluoroacetamide to trimethylsilyl ethers.The derivation products were analyzed by capillary column GC combined with electron impact MS using scan and selected ion monitor (SIM) modes. Signals of cholesterol internal standard were corrected for the contributions from cholesterol and the signal ratio of cholesterol to internal standard for the calibrators were linearly regressed against cholesterol concentrations.The resulted regression equation was used for the calculation of serum cholesterol concentrations.Results The new ID/GC/MS method showed a mean within-run coefficient variance (CV) of 0.04%-0.81%.Comparison with two levels of standard reference material (SRM1951a) of National Institute of Standards and Technology (NIST) displayed a bias of 0.19% and 0.90% respectively.Conclusion A time-gaining ID/MS method has been established that is highly precise and accurate and can be used for the measurement of serum cholesterol.
10.Involvement of AMP-activated Protein Kinase α/ Nuclear Factor (Erythroid-derived 2) Like 2-iniatived Signaling Pathway in Cytoprotective Effects of Wasabi 6-(Methylsulfinyl) Hexyl Isothiocyanate
Xuchi PAN ; Kun XIE ; Keyu CHEN ; Ziyu HE ; Kozue SAKAO ; De-Xing HOU
Journal of Cancer Prevention 2022;27(1):58-67
6-(Methylsulfinyl) hexyl isothiocyanate (6-MSITC) is an active ingredient present in Wasabi, which is a popular pungent spice used in Japanese cuisine. Our previous studies suggested that the primary antioxidant activity of 6-MSITC may link to other biological activity. This study aimed to clarify how the antioxidant activity of 6-MSITC contributes to preventing overloaded lipid stress in he-patic cell model. HepG2 cells were treated with 6-MSITC at defined concentrations and times in normal medium or in combined fatty acids (CFA) medium, and the targeted proteins were detected by Western blotting. The kinetic data revealed that 6-MSITC activated AMP-activated protein kinase α (AMPKα) and nuclear factor (erythroid-derived 2) like 2 (Nrf2), and then enhanced the protein expression of Forkhead box protein O1 (FOXO1) and Sirtuin1 as well as that of the Nrf2 target proteins, NAD(P)H:quinone oxidoreductase 1 (NQO1) and heme oxygenase (HO-1). Furthermore, lipid metabolic stress was mimicked in HepG2 cells by overloading CFA. 6-MSITC significantly alleviated CFA-induced formation of thiobarbituric acid reactive substances and fat ac-cumulation. Signaling analysis data revealed that 6-MSITC enhanced phosphorylation of AMPKα, upregulated the expression of Nrf2, NQO1, heme oxygenase 1, FOXO1, and Siruin1, and downregulated the expression of PPARα. Taken together, our results suggested that the AMPKα/Nrf2-mediated signaling pathways might be involved in the cytoprotective effects of Wasabi 6-MSITC against metabolic lipid stress.