1.Clinical Effect and Imaging Evaluation of Tendon-Management and Patella-Movement Therapeutic Manipulation for Patellofemoral Arthritis:A Randomised Controlled Trial
Jinguang GU ; Guangcheng WEI ; Yong ZHAO ; Yongli DONG ; Zechuan ZHUO ; Aolin SUN ; Weikai QIN
Journal of Traditional Chinese Medicine 2025;66(13):1350-1356
ObjectiveTo evaluate the therapeutic effect and mechanism of tendon-management and patella-movement therapeutic manipulation in the treatment of patellofemoral arthritis based on imaging evaluation. MethodsTotally 126 patients with patellofemoral arthritis were recruited and divided into a treatment group and a control group according to a randomised numerical table. The control group received routine sodium hyaluronate injection once a week for a total of 5 times; the treatment group received tendon-management and patella-movement therapeutic manipulation three times a week for four weeks. We compared the Western Ontario and McMaster University osteoarthritis index score (WOMAC), visual analogue scale (VAS), imaging indicators including patellar external displacement distance, patellofemoral fit angle, lateral patellofemoral angle, and patellofemoral index, and overall effectiveness evaluation between the two groups before and one week after treatment. ResultsThe total effective rate of the treatment group (45/54, 83.33%) was significantly higher than that of the control group (36/54, 66.67%,P<0.05). One week after the end of treatment, the VAS scores and WOMAC scores of both groups were lower than those before treatment in the same group (P<0.01), and the patellofemoral index and patellofemoral fit angle of the treatment group decreased compared with that of the control group (P<0.05). Compared with the pre-treatment, the distance of patellar external displacement, patellofemoral index, and patellofemoral fit angle decreased in the treatment group 1 week after the end of treatment, and the patellofemoral fit angle decreased in the control group (P<0.05). ConclusionThe therapeutic manipulation of tendon-management and patella-movement can correct the degree of patellar external displacement, alleviate joint pain symptoms, improve joint function, and achieve the goal of treating patellofemoral arthritis.
3.Early clinical outcomes of 3D-printed individualised customised prostheses in hip revision combined severe bone defect.
Hong-Ping WANG ; Ming-You WANG ; Xiao-Qin YANG ; Zhuo-Dong TANG ; Xun-Zhou SONG ; Yu-Ping LAN
China Journal of Orthopaedics and Traumatology 2025;38(2):163-169
OBJECTIVE:
To explore the early clinical outcomes of 3D printed individualised customised prostheses for in hip revision in patients with combined severe bone defects.
METHODS:
Twenty-two patients from January 2021 to May 2023 underwent hip revision using 3D printed personalised customised prostheses were retrospective analyzed, including 10 males and 12 females, age 28 to 78 with a mean of (58.9±12.8) years old. All of patients were combined with severe bone defects (Parprosky type Ⅲ). Among of them, 9 patients had periprosthetic infections and 13 patients had aseptic prosthesis loosening. All patients were treated with a 3D printed personalised prosthesis protocol, patients with the periprosthetic infection received a second stage revision after infection control. The operation time, preoperative waiting time, intraoperative and postoperative complications were recorded, and the clinical efficacy were evaluated at the final follow-up using the visual analogue scale (VAS) for pain, the Harris hip score.
RESULTS:
One patient was lost to follow-up and the remaining 21 patients were followed up for 10 to 15 with a mean of (12.91±1.44) months after surgery. All patients completed surgery as planned, with an operative time of 135 to 390 with a mean of (165.4±39.3) minutes and a preoperative waiting time of 7 to 16 with a mean of (10.5±3.3) days. Regarding patient complications:one patient had a severe intraoperative periprosthetic femoral fracture due to the combination of severe osteoporosis; one patient had an intraoperative greater trochanteric femur fracture. At the latest follow-up, all patients had good position of the custom-made prosthesis and no loosening of the prosthesis;all patients had good wound healing and no local redness or swelling. The total Harris score at the final follow-up (85.86±7.04) was significantly improved compared to the preoperative (44.86±2.36), P<0.001. The VAS at the last follow-up (2.19±0.87) was significantly improved compared with preoperative (7.41±0.96), P<0.001.
CONCLUSION
The clinical efficacy of 3D-printed personalised customised prosthesis in combined severe bone defect hip revision is satisfactory, but due to the increased preoperative waiting time of the patients and certain risks, certain indications should be mastered when applying in the clinic.
Humans
;
Male
;
Female
;
Printing, Three-Dimensional
;
Middle Aged
;
Aged
;
Adult
;
Retrospective Studies
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip
;
Reoperation
;
Prosthesis Design
;
Treatment Outcome
4.Predictive value of preoperative inflammatory response indicators for incisional infection after spinal surgery.
Wei LIANG ; Rui-Li ZHUO ; Shao-Dong SUN
China Journal of Orthopaedics and Traumatology 2025;38(2):183-187
OBJECTIVE:
To explore the clinical significance of preoperative neutrophil to lymphocyte ratio (NLR), platelet to lymphocyte ratio (PLR), and C-reactive protein (CRP) to albumin (ALB) ratio in spinal surgery patients with postoperative incision infection.
METHODS:
A total of 373 patients who underwent spinal surgery were collected and devided into two groups according to the postoperative incision infection situation. Among them, 65 cases in the incision infection group included 34 males and 31 females with a mean age of (56.01±9.78) years old;308 cases in the non incision infection group included 157 males and 151 females with a mean age of (55.54±10.19) years old. Blood cell analyzer was applied to detect neutrophils, lymphocytes, and platelets, and calculate NLR and PLR;immunoturbidimetry was applied to measure serum CRP and ALB levels and calculate CRP/ALB ratio;receiver operating characteristic (ROC) curve was applied to analyze the predictive value of preoperative NLR, PLR, and CRP/ALB ratio for postoperative spinal incision infection;Logistic multivariate regression was applied to analyze the influencing factors of incision infection after spinal surgery.
RESULTS:
The NLR(4.92±1.13), PLR (119.32±22.74), CRP/ALB ratio (10.19±2.51), operation time (3.02±0.64) h, history of diabetes 38.46%(25/65), and the proportion of patients with implant 32.31%(21/65) in the incision infection group were higher than those in the non incision infection group 3.72±0.81, 90.58±20.16, 7.23±2.21, (2.26±0.51) h, 16.88%(53/308), 11.69%(36/308), there were statistical differences(P<0.05). The AUC of preoperative NLR, PLR, and CRP/ALB ratio alone and in combination for predicting postoperative incision infection after spinal surgery was 0.786, 0.806, 0.839, and 0.926, respectively. Preoperative NLR, PLR, and CRP/ALB ratio were independent risk factors for postoperative incision infection in spinal surgery(P<0.05).
CONCLUSION
The determination of preoperative NLR, PLR, and CRP/ALB ratio is beneficial for early prediction of postoperative spinal incision infection, and the combined detection of the three can further improve the accuracy of the prediction results.
Humans
;
Male
;
Female
;
Middle Aged
;
Aged
;
C-Reactive Protein/metabolism*
;
Surgical Wound Infection/etiology*
;
Adult
;
Spine/surgery*
;
Inflammation
;
Preoperative Period
5.Comparison of application and efficacy of domestic HURWA and imported Smith & Nephew Cori robots in total knee arthroplasty.
Ming-You WANG ; Zhuo-Dong TANG ; Yu-Ping LAN ; Heng XIAO ; Ming-Li WANG ; Xun-Zhou SONG ; Hong-Ping WANG
China Journal of Orthopaedics and Traumatology 2025;38(10):1027-1036
OBJECTIVE:
Investigation on the clinical application of HURWA robot and Smith & Nephew Cori robot in total knee arthroplasty(TKA).
METHODS:
A retrospective analysis was performed on 84 patients with knee osteoarthritis who underwent robotic-assisted TKA (RATKA) between June 2023 and March 2025. According to the different robotic systems used, the patients were divided into the domestic HUARUN robotic-assisted total knee arthroplasty group (HRATKA group) and the Smith & Nephew Cori robotic-assisted total knee arthroplasty group (CRATKA group). There were 42 patients in the HRATKA group, including 16 males and 26 females; the age ranged from 56 to 73 years old, with an average of (64.70±8.30) years old;the body mass index (BMI) was (25.10±2.30) kg·m-2;21 cases were on the right side and 21 cases on the left side;in terms of Kellgren-Lawrence(K-L) classification, there were 15 cases of Grade Ⅲ and 27 cases of Grade Ⅳ;the disease duration ranged from 3 to 25 years, with an average of (15.5±7.5) years. The CRATKA group also included 42 patients, with 14 males and 28 females;the age ranged from 58 to 74 years old, with an average of (65.60±7.50) years old;the BMI was (24.50±2.70) kg·m-2; 20 cases were on the right side and 22 cases on the left side;regarding K-L classification, there were 11 cases of Grade Ⅲ and 31 cases of Grade Ⅳ;the disease duration ranged from 2 to 26 years, with an average of (16.5±8.8) years. Collect general data of all patients, including age, gender, height, weight, surgical site, K-L classification, incision length, and operation time. To evaluate prosthesis position, compare the frontal tibia component (FTC) angle, lateral femoral component (LFC) angle, lateral tibia component (LTC) angle, and frontal femoral component angle between the two groups of patients after surgery. Measure the deviation of the hip-knee-ankle (HKA) angle to assess lower limb alignment. Additionally, compare the following indicators between the two groups:Knee Society Score (KSS), Visual Analogue Scale (VAS) for pain, knee range of motion (ROM), hemoglobin (HB) level, hematocrit (HCT) level, complication rate, and in-hospital satisfaction.
RESULTS:
All patients successfully completed the surgery as scheduled, and all were followed up after the operation. The follow-up period ranged from 5 to 17 months with an average of (11.2±6.1) months. There were 4 cases of venous thrombosis in the HRATKA group and 3 cases in the CRATKA group;each group had 2 cases of wound exudation. No mechanical-related complications, pulmonary embolism, or other severe complications occurred. Comparison of the incision length and hospital stay between the HRATKA group and the CRATKA group showed no statistically significant difference (P>0.05). The operation time in the HRATKA group was (96.80±7.10) minutes, which was longer than that in the CRATKA group (90.10±8.80) minutes, and the difference was statistically significant (P<0.05). In the HRATKA group, the HKA angle was (178.93±1.11) degree, the FFC angle was (89.00±0.91)°, and the LFC angle was (7.31±2.17) degree;the corresponding values in the CRATKA group were (178.05±1.34)°, (87.88±1.74)°, and (10.60±2.84) degree respectively. The differences in these three indicators between the two groups were all statistically significant (P<0.05). However, there were no statistically significant differences in the FTC angle or LTC angle between the two groups (P>0.05). There was also no statistically significant difference in the total perioperative blood loss between the two groups (P>0.05). At 3 days after surgery, the VAS score for movement in the HRATKA group (5.95±1.45) points was higher than that in the CRATKA group (4.50±0.97) points, with a statistically significant difference (P<0.05);at 90 days after surgery, there was no statistically significant difference in the movement VAS score between the two groups (P>0.05). Additionally, no statistically significant differences were observed between the two groups in the KSS, ROM at 3 and 90 days after surgery, or satisfaction degree during hospitalization (all P>0.05).
CONCLUSION
The domestic HURWA robot demonstrates excellent performance in osteotomy efficiency and lower limb alignment recovery. The Smith & Nephew Cori robot has a significant advantage in soft tissue assessment and joint stability optimization. Both robotic systems offer high-quality surgical treatments that significantly improve short-term knee function.
Humans
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Aged
;
Middle Aged
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Osteoarthritis, Knee/surgery*
6.Immunophenotypic Characteristics of Bone Marrow Granulocytes and Their Clinical Significance in Patients with Multiple Myeloma.
Ning-Fang WANG ; Chong-Shan ZHAO ; Dong-Dong ZHANG ; Zhuo-Wen CAI ; Fang-Fang CAI ; Fang LIU ; Peng-Hao ZHAO
Journal of Experimental Hematology 2025;33(2):447-454
OBJECTIVE:
To explore the immunophenotypic characteristics of bone marrow granulocytes (G) and their clinical significance in patients with multiple myeloma (MM).
METHODS:
The granulocyte immunophenotypes of bone marrow in 70 MM patients (MM group) and 40 anemia patients (control group) were detected by flow cytometry, and its correlation with clinical characteristics was further analyzed. Univariate and multivariate regression analysis were used to screen factors that affected prognosis.
RESULTS:
The CD56+G%, CD13+G%, CD22+G% and CD117+G% in MM group were higher than those in the control group (all P <0.05). CD56+G% and CD117+G% in CR+VGPR group were significantly lower than those in PR+MR+PD group (both P <0.05). The CD10+G% in RISS Ⅲ stage and Ca2+ ≥2.65 mmol/L groups were increased (both P <0.05). The CD56+G% in elevated lactate dehydrogenase, β2-microglobulin≥5.5 mg/L and hemoglobin <85 g/L groups were increased (all P <0.05), while the CD117+G% in high-risk cytogenetic positive group was decreased (P <0.05). The expression rate of CD molecules on granulocytes was divided into low (L) and high (H) groups according to the median value. The overall survival (OS) of the LCD56+G%, LCD13+G% and LCD22+G% groups was significantly prolonged (all P <0.05). CD13+G% and CD22+G% were independent risk factors for OS in MM patients (HR=0.443, 0.410, both P <0.05).
CONCLUSION
The CD56+G%, CD10+G% and CD117+G% are closely correlated with clinical features in MM patients, while CD13+G% and CD22+G% are closely correlated with prognosis. Detection of CD molecules expression on granulocytes may be used to evaluate prognosis and guide treatment.
Humans
;
Multiple Myeloma/immunology*
;
Granulocytes/immunology*
;
Prognosis
;
Immunophenotyping
;
Male
;
Bone Marrow
;
Female
;
Flow Cytometry
;
Middle Aged
;
Aged
;
Clinical Relevance
7.A practice guideline for therapeutic drug monitoring of mycophenolic acid for solid organ transplants.
Shuang LIU ; Hongsheng CHEN ; Zaiwei SONG ; Qi GUO ; Xianglin ZHANG ; Bingyi SHI ; Suodi ZHAI ; Lingli ZHANG ; Liyan MIAO ; Liyan CUI ; Xiao CHEN ; Yalin DONG ; Weihong GE ; Xiaofei HOU ; Ling JIANG ; Long LIU ; Lihong LIU ; Maobai LIU ; Tao LIN ; Xiaoyang LU ; Lulin MA ; Changxi WANG ; Jianyong WU ; Wei WANG ; Zhuo WANG ; Ting XU ; Wujun XUE ; Bikui ZHANG ; Guanren ZHAO ; Jun ZHANG ; Limei ZHAO ; Qingchun ZHAO ; Xiaojian ZHANG ; Yi ZHANG ; Yu ZHANG ; Rongsheng ZHAO
Journal of Zhejiang University. Science. B 2025;26(9):897-914
Mycophenolic acid (MPA), the active moiety of both mycophenolate mofetil (MMF) and enteric-coated mycophenolate sodium (EC-MPS), serves as a primary immunosuppressant for maintaining solid organ transplants. Therapeutic drug monitoring (TDM) enhances treatment outcomes through tailored approaches. This study aimed to develop an evidence-based guideline for MPA TDM, facilitating its rational application in clinical settings. The guideline plan was drawn from the Institute of Medicine and World Health Organization (WHO) guidelines. Using the Delphi method, clinical questions and outcome indicators were generated. Systematic reviews, Grading of Recommendations Assessment, Development, and Evaluation (GRADE) evidence quality evaluations, expert opinions, and patient values guided evidence-based suggestions for the guideline. External reviews further refined the recommendations. The guideline for the TDM of MPA (IPGRP-2020CN099) consists of four sections and 16 recommendations encompassing target populations, monitoring strategies, dosage regimens, and influencing factors. High-risk populations, timing of TDM, area under the curve (AUC) versus trough concentration (C0), target concentration ranges, monitoring frequency, and analytical methods are addressed. Formulation-specific recommendations, initial dosage regimens, populations with unique considerations, pharmacokinetic-informed dosing, body weight factors, pharmacogenetics, and drug-drug interactions are covered. The evidence-based guideline offers a comprehensive recommendation for solid organ transplant recipients undergoing MPA therapy, promoting standardization of MPA TDM, and enhancing treatment efficacy and safety.
Mycophenolic Acid/administration & dosage*
;
Drug Monitoring/methods*
;
Humans
;
Organ Transplantation
;
Immunosuppressive Agents/administration & dosage*
;
Delphi Technique
8.Small-molecule drug design strategies for regulating protein phosphorylation modification
Wen-yan YANG ; Jia-yi WANG ; Feng-jiao LIN ; Ke-ran WANG ; Yu-zhuo WU ; Zhao-cheng WANG ; Qi-dong YOU ; Lei WANG ; Qiu-yue ZHANG
Acta Pharmaceutica Sinica 2024;59(11):2912-2925
Protein phosphorylation modification is an important mechanism of physiological regulation that is closely related to protein biological functions. In particular, protein kinases are responsible for catalyzing the phosphorylation process of proteins, and phosphatases are responsible for catalyzing the dephosphorylation process of phosphorylation-modified proteins, which together mediate the achievement of dynamic and reversible phosphorylation modifications of proteins. Abnormal phosphorylation levels of proteins contribute to the development of many diseases, such as cancer, neurodegenerative diseases, and chronic diseases. Therefore, rational design of small molecules to regulate protein phosphorylation is an important approach for disease treatment. Based on the mechanism of protein phosphorylation regulation, small molecule drug design strategies can be classified into three types, protein kinase modulators, phosphatase modulators, and bifunctional molecules with proximity-mediated mechanism. This review emphasizes the above three small molecule design strategies for targeting protein phosphorylation regulation, including molecular design ideas, research progress and current challenges, and provides an outlook on small molecule modulators targeting protein phosphorylation modification.
9.Clinical characteristics and nutritional status of children with Crohn's disease and risk factors for malnutrition
Dong-Dan LI ; Xiao-Lin YE ; Mei-Chen WANG ; Hong-Mei HUANG ; Jie YAN ; Tian-Zhuo ZHANG ; Fei-Hong YU ; De-Xiu GUAN ; Wen-Li YANG ; Lu-Lu XIA ; Jie WU
Chinese Journal of Contemporary Pediatrics 2024;26(11):1194-1201
Objective To investigate the nutritional status of children with Crohn's Disease (CD) at diagnosis and its association with clinical characteristics. Methods A retrospective analysis was performed for the clinical data and nutritional status of 118 children with CD who were admitted to Beijing Children's Hospital,Capital Medical University,from January 2016 to January 2024. A multivariate logistic regression analysis was used to investigate the risk factors for malnutrition. Results A total of 118 children with CD were included,among whom there were 68 boys (57.6%) and 50 girls (42.4%),with a mean age of (11±4) years. Clinical symptoms mainly included recurrent abdominal pain (73.7%,87/118),diarrhea (37.3%,44/118),and hematochezia (32.2%,38/118),and 63.6% (75/118) of the children had weight loss at diagnosis. The incidence rate of malnutrition was 63.6% (75/118),and the children with moderate or severe malnutrition accounted for 67% (50/75). There were 50 children (42.4%) with emaciation,8 (6.8%) with growth retardation,and 9 (7.6%) with overweight or obesity. Measurement of nutritional indices showed a reduction in serum albumin in 83 children (70.3%),anemia in 74 children (62.7%),and a reduction in 25 hydroxyvitamin D in 15 children (60%,15/25). The children with malnutrition had significantly higher disease activity,proportion of children with intestinal stenosis,and erythrocyte sedimentation rate and a significant reduction in serum albumin (P<0.05). The multivariate logistic regression analysis showed that intestinal stenosis was an independent risk factor for malnutrition in children with CD (OR=4.416,P<0.05). Conclusions There is a high incidence rate of malnutrition in children with CD at diagnosis,which is associated with disease activity and disease behavior. The nutritional status of children with CD should be closely monitored.
10.A retrospective study on two different surgical robots to assist total knee arthroplasty
Hong-Ping WANG ; Ming-You WANG ; Zhuo-Dong TANG ; Qi-Feng TAO ; Yu-Ping LAN
China Journal of Orthopaedics and Traumatology 2024;37(9):870-877
Objective To compare early clinical and imaging results of domestic HURWA and imported Brainlab Knee3 surgical robot-assisted knee replacement.Methods A retrospective analysis was performed on 93 patients with knee os-teoarthritis(KOA)who underwent robot-assisted descending total knee arthroplasty(TKA)from January 2021 to July 2023,and they were divided into BRATKA group and HRATKA group according to use of robotic system.There were 40 patients in BRATKA group,including 16 males and 24 females,aged from 55 to 90 years old with an average of(64.3±7.0)years old;27 patients with grade Ⅲ and 13 patients with grade Ⅳ according to Kellgren-Lawrence(K-L);18 patients on the right side and 22 patients on the left side;the courses of disease ranged from 1 to 30 years with an average of(15.3±7.6)years;imported Brainlab Knee3 surgical robot assisted system was adopted.There were 53 patients in HRATKA group,including 18 males and 35 females,aged from 52 to 81 years old with an average of(64.4±8.5)years old;30 patients with grade Ⅲ and 23 patients with grade Ⅳ;21 patients on the right side and 32 patients on the left side;the courses of disease ranged from 1 to 32 years with an average of(16.4±7.9)years;HURWA surgical robot assisted system was adopted.Operation time,perioperative total blood loss,incision length and postoperative complications were compared between two groups.Deviation angle of hip-knee-an-kle angle(HKAA)before operation and on the first day after operation was compared between two groups.Later tibal compo-nent(LTC),frontal femoral component(FFC),later femoral component(LFC)and frontal tibal component(FTC)at 1 day af-ter on the first day after operation was compared between two groups.Knee Society score(KSS),visual analogue scale(VAS)and range of motion(ROM)of knee joint were compared between two groups before operation and on the 3rd and 90th day af-ter operation.Results Both groups were followed up for 11 to 18 months with an average of(14.4±2.1)months,and the wounds of all patients healed well.Operation time and incision length of BRATKA group were(132.1±34.6)min and(12.9±1.9)cm,while(94.1±10.8)min and(14.8±2.1)cm in HRATKA group,respectively,and the differences between two groups were statistically significant(P<0.05).There were no significant difference in perioperative total blood loss and preoperative deviation angle of HKAA between two groups(P>0.05).Deviation angle of HKAA,FFC angle and LFC angle in BRATKA group were(1.90±0.91)°,(87.90±1.51)°and(9.00±3.2)°,respectively;while(0.93±1.04)°,(89.03±0.96)° and(7.63±0.59)° in HRATKA group,respectively,and the differences between two groups were statistically significant(P<0.05).There were no significant dif-ferences in FTC and LTC between two groups(P>0.05).There were no significant differences in VAS of knee rest and exercise,KSS score and ROM of knee joint between two groups before operation and 3 days and 90 days after operation(P>0.05).There was no significant difference in complications between two groups(P>0.05).Conclusion Postoperative imaging of two robot systems showed good lower limb force line.The domestic HRATKA group had better LFC,FFC angle and HKA deviation angle than the imported BRATKA group,but there were no significant difference in postoperative knee function and pain relief.

Result Analysis
Print
Save
E-mail