1.Is Braun Jejunojejunostomy Necessary? Comparison Between Billroth-II Alone and Billroth-II With Braun Anastomosis After Distal Gastrectomy
Jane Chungyoon KIM ; Min Jung LEE ; Hyuk-Joon LEE ; Kyoyoung PARK ; Min Kyu KANG ; Sa-Hong KIM ; Chun ZHUANG ; Abdullah ALMAYOUF ; Ma. Jeanesse C. BERNARDO ; Jeesun KIM ; Yo-Seok CHO ; Seong-Ho KONG ; Soo-Jeong CHO ; Do Joong PARK ; Han-Kwang YANG
Journal of Gastric Cancer 2025;25(2):318-329
Purpose:
The optimal reconstruction method following distal gastrectomy has not been elucidated. Since Billroth-II (B-II) reconstruction is commonly associated with increased bile reflux, Braun jejunojejunostomy has been proposed to reduce this complication.
Materials and Methods:
We retrospectively analyzed 325 patients with gastric cancer who underwent distal gastrectomy with B-II reconstruction between January 2015 and December 2017, comprising 159 patients without Braun anastomosis and 166 with Braun anastomosis.Outcomes were assessed over three years using annual gastroscopy based on the residual food, gastritis, and bile reflux criteria and the Los Angeles classification for reflux esophagitis.
Results:
In the first postoperative year, the group with Braun anastomosis showed a significant reduction in bile reflux compared to the group without Braun anastomosis (75.9% vs. 86.2%; P=0.019). Moreover, multivariate analysis identified Braun anastomosis as the sole factor associated with this outcome. Additionally, the group with Braun anastomosis had a lower incidence of heartburn (12.0% vs. 20.1%; P=0.047) and reduced use of prokinetics (P<0.001) and acid reducers (P=0.002) compared to the group without Braun anastomosis.However, these benefits diminished in subsequent years, with no significant differences in residual food, gastritis, or reflux esophagitis between the groups. Both groups showed similar body mass index scores and nutritional outcomes over the 3-year follow-up period.
Conclusions
Although Braun anastomosis offers short-term benefits in reducing bile reflux after B-II reconstruction, these effects are not sustainable. The routine use of Braun anastomosis should be reconsidered, though either approach remains a viable option depending on the patient’s circumstances.
2.Is Braun Jejunojejunostomy Necessary? Comparison Between Billroth-II Alone and Billroth-II With Braun Anastomosis After Distal Gastrectomy
Jane Chungyoon KIM ; Min Jung LEE ; Hyuk-Joon LEE ; Kyoyoung PARK ; Min Kyu KANG ; Sa-Hong KIM ; Chun ZHUANG ; Abdullah ALMAYOUF ; Ma. Jeanesse C. BERNARDO ; Jeesun KIM ; Yo-Seok CHO ; Seong-Ho KONG ; Soo-Jeong CHO ; Do Joong PARK ; Han-Kwang YANG
Journal of Gastric Cancer 2025;25(2):318-329
Purpose:
The optimal reconstruction method following distal gastrectomy has not been elucidated. Since Billroth-II (B-II) reconstruction is commonly associated with increased bile reflux, Braun jejunojejunostomy has been proposed to reduce this complication.
Materials and Methods:
We retrospectively analyzed 325 patients with gastric cancer who underwent distal gastrectomy with B-II reconstruction between January 2015 and December 2017, comprising 159 patients without Braun anastomosis and 166 with Braun anastomosis.Outcomes were assessed over three years using annual gastroscopy based on the residual food, gastritis, and bile reflux criteria and the Los Angeles classification for reflux esophagitis.
Results:
In the first postoperative year, the group with Braun anastomosis showed a significant reduction in bile reflux compared to the group without Braun anastomosis (75.9% vs. 86.2%; P=0.019). Moreover, multivariate analysis identified Braun anastomosis as the sole factor associated with this outcome. Additionally, the group with Braun anastomosis had a lower incidence of heartburn (12.0% vs. 20.1%; P=0.047) and reduced use of prokinetics (P<0.001) and acid reducers (P=0.002) compared to the group without Braun anastomosis.However, these benefits diminished in subsequent years, with no significant differences in residual food, gastritis, or reflux esophagitis between the groups. Both groups showed similar body mass index scores and nutritional outcomes over the 3-year follow-up period.
Conclusions
Although Braun anastomosis offers short-term benefits in reducing bile reflux after B-II reconstruction, these effects are not sustainable. The routine use of Braun anastomosis should be reconsidered, though either approach remains a viable option depending on the patient’s circumstances.
3.Is Braun Jejunojejunostomy Necessary? Comparison Between Billroth-II Alone and Billroth-II With Braun Anastomosis After Distal Gastrectomy
Jane Chungyoon KIM ; Min Jung LEE ; Hyuk-Joon LEE ; Kyoyoung PARK ; Min Kyu KANG ; Sa-Hong KIM ; Chun ZHUANG ; Abdullah ALMAYOUF ; Ma. Jeanesse C. BERNARDO ; Jeesun KIM ; Yo-Seok CHO ; Seong-Ho KONG ; Soo-Jeong CHO ; Do Joong PARK ; Han-Kwang YANG
Journal of Gastric Cancer 2025;25(2):318-329
Purpose:
The optimal reconstruction method following distal gastrectomy has not been elucidated. Since Billroth-II (B-II) reconstruction is commonly associated with increased bile reflux, Braun jejunojejunostomy has been proposed to reduce this complication.
Materials and Methods:
We retrospectively analyzed 325 patients with gastric cancer who underwent distal gastrectomy with B-II reconstruction between January 2015 and December 2017, comprising 159 patients without Braun anastomosis and 166 with Braun anastomosis.Outcomes were assessed over three years using annual gastroscopy based on the residual food, gastritis, and bile reflux criteria and the Los Angeles classification for reflux esophagitis.
Results:
In the first postoperative year, the group with Braun anastomosis showed a significant reduction in bile reflux compared to the group without Braun anastomosis (75.9% vs. 86.2%; P=0.019). Moreover, multivariate analysis identified Braun anastomosis as the sole factor associated with this outcome. Additionally, the group with Braun anastomosis had a lower incidence of heartburn (12.0% vs. 20.1%; P=0.047) and reduced use of prokinetics (P<0.001) and acid reducers (P=0.002) compared to the group without Braun anastomosis.However, these benefits diminished in subsequent years, with no significant differences in residual food, gastritis, or reflux esophagitis between the groups. Both groups showed similar body mass index scores and nutritional outcomes over the 3-year follow-up period.
Conclusions
Although Braun anastomosis offers short-term benefits in reducing bile reflux after B-II reconstruction, these effects are not sustainable. The routine use of Braun anastomosis should be reconsidered, though either approach remains a viable option depending on the patient’s circumstances.
4.Clinical evaluation of centrally procured generic and original esomeprazole for the treatment of acute non-variceal upper gastrointestinal bleeding
Si SU ; Shaowei HAN ; Haicai ZHUANG ; Na XU ; Ying LI ; Xiao WANG ; Kuan LI
China Pharmacy 2025;36(13):1635-1640
OBJECTIVE To evaluate the efficacy, safety and economics of the centrally procured generic versus original esomeprazole in the treatment of acute non-variceal upper gastrointestinal bleeding (ANVUGIB). METHODS A retrospective collection of real-world clinical data was conducted for ANVUGIB patients who received treatment at Shenzhen People’s Hospital and University of Hong Kong-Shenzhen Hospital from January 2018 to March 2024. Patients were divided into imported original drug group (original drug group, 221 cases) and centrally procured generic drug group (generic drug group, 75 cases) according to the types of drug used. Propensity score matching (PSM) was performed at a ratio of 3∶1 to compare the clinical efficacy, safety and economics between the two groups. RESULTS Totally 241 patients were included after PSM, with 170 in the original drug group and 71 in the generic drug group. There were no significant differences between the two groups in terms of rebleeding rate, rate of second endoscopic intervention, blood transfusion rate, length of hospital stay, mortality due to gastrointestinal bleeding, 30-day readmission due to rebleeding, and overall survival rate (P>0.05). The incidence of adverse events among all patients in both groups also showed no statistically significant difference (P>0.05); furthermore, the adverse events reported by the respective hospitals to the National Center for ADR Monitoring were comparable between the two groups. After PSM, the median total drug cost and high-dose esomeprazole cost in the generic drug group were significantly lower than those in the original drug group, while the median nursing fee and bed fee were significantly higher than those in the original drug group (P<0.05). There was no statistically significant difference between the two groups in terms of median total hospitalization expenses, total treatment costs, laboratory fees, examination fees, material costs, or consultation fees (P>0.05). CONCLUSIONS The clinical efficacy and safety of centrally procured generic esomeprazole in the treatment of ANVUGIB are comparable to those of the original drug, and it is more economical.
5.Analysis of the effect of intraocular injection of recombinant tissue plasminogen activator on pars plana vitrectomy outcomes in patients with rupture of the globe
Shaoxi ZHUANG ; Zhengxia XIAO ; Beibei HAN ; Jianwei LIU
International Eye Science 2025;25(12):2052-2055
AIM: To investigate the effect of intravitreal injection of recombinant tissue plasminogen activator(r-TPA)before pars plana vitrectomy(PPV)on surgical outcomes in patients with rupture of the globe(RG).METHODS: A retrospective study was conducted on 37 patients(37 eyes)with RG who underwent PPV 7-10 d after Stage Ⅰ suturing and stabilization at our hospital between April 2020 and November 2023. Based on whether an intravitreal r-TPA injection was administered 1 d before PPV, patients were divided into two groups, with 14 cases(14 eyes)in pre-operative r-TPA injection group, and 23 cases(23 eyes)in control group without pre-operative r-TPA injection. The intraoperative retinal reattachment rate, intraoperative silicone oil application, postoperative intraocular rebleeding, postoperative hypotony, and best-corrected visual acuity(BCVA)were compared between the two groups.RESULTS: The baseline characteristics were comparable between the two groups(P>0.05). Significant differences were found between the two groups in the intraoperative retinal reattachment rate, the volume of silicone oil injected, and the proportion of BCVA(all P<0.05). No statistically significant differences were observed in the intraoperative silicone oil tamponade rate, postoperative intraocular rebleeding, or postoperative hypotony rates(all P>0.05).CONCLUSION: RG patients who received an intravitreal r-TPA injection 1 d before PPV demonstrated significantly higher intraoperative retinal reattachment rates and better postoperative visual acuity outcomes.
6.Regulatory effects of Dangua Humai Oral Liquid on gut microbiota and mucosal barrier in mice with glucolipid metabolism disorder.
Zhuang HAN ; Lin-Xi JIN ; Zhi-Ta WANG ; Liu-Qing YANG ; Liang LI ; Yi RUAN ; Qi-Wei CHEN ; Shu-Hong YAO ; Xian-Pei HENG
China Journal of Chinese Materia Medica 2025;50(15):4315-4324
The gut microbiota regulates intestinal nutrient absorption, participates in modulating host glucolipid metabolism, and contributes to ameliorating glucolipid metabolism disorder. Dysbiosis of the gut microbiota can compromise the integrity of the intestinal mucosal barrier, induce inflammatory responses, and exacerbate insulin resistance and abnormal lipid metabolism in the host. Dangua Humai Oral Liquid, a hospital-developed formulation for regulating glucolipid metabolism, has been granted a national invention patent and demonstrates significant clinical efficacy. This study aimed to investigate the effects of Dangua Humai Oral Liquid on gut microbiota and the intestinal mucosal barrier in a mouse model with glucolipid metabolism disorder. A glucolipid metabolism disorder model was established by feeding mice a high-glucose and high-fat diet. The mice were divided into a normal group, a model group, and a treatment group, with eight mice in each group. The treatment group received a daily gavage of Dangua Humai Oral Liquid(20 g·kg~(-1)), while the normal group and model group were given an equivalent volume of sterile water. After 15 weeks of intervention, glucolipid metabolism, intestinal mucosal barrier function, and inflammatory responses were evaluated. Metagenomics and untargeted metabolomics were employed to analyze changes in gut microbiota and associated metabolic pathways. Significant differences were observed between the indicators of the normal group and the model group. Compared with the model group, the treatment group exhibited marked improvements in glucolipid metabolism disorder, alleviated pathological damage in the liver and small intestine tissue, elevated expression of recombinant claudin 1(CLDN1), occluding(OCLN), and zonula occludens 1(ZO-1) in the small intestine tissue, and reduced serum levels of inflammatory factors lipopolysaccharides(LPS), lipopolysaccharide-binding protein(LBP), interleukin-6(IL-6), and tumor necrosis factor-α(TNF-α). At the phylum level, the relative abundance of Bacteroidota decreased, while that of Firmicutes increased. Lipid-related metabolic pathways were significantly altered. In conclusion, based on the successful establishment of the mouse model of glucolipid metabolism disorder, this study confirmed that Dangua Humai Oral Liquid effectively modulates gut microbiota and mucosal barrier function, reduces serum inflammatory factor levels, and regulates lipid-related metabolic pathways, thereby ameliorating glucolipid metabolism disorder.
Animals
;
Gastrointestinal Microbiome/drug effects*
;
Mice
;
Intestinal Mucosa/microbiology*
;
Male
;
Drugs, Chinese Herbal/administration & dosage*
;
Mice, Inbred C57BL
;
Humans
;
Glycolipids/metabolism*
;
Lipid Metabolism/drug effects*
;
Administration, Oral
;
Disease Models, Animal
7.Study of The Y-STR Multiplex Microfluidic Chip Rapid Amplification System
Dao-Yu WANG ; Qun WAN ; Bin ZHUANG ; Li-Jian ZHAO ; Jun-Ping HAN ; Cai-Xia LI
Progress in Biochemistry and Biophysics 2024;51(3):696-705
ObjectiveAt present, the matching reagents of commercially available rapid DNA instruments based on microfluidics chip technology are autosome short tandem repeat (STR) individual identification reagents. The non-recombining part of the human Y chromosome is widely used in forensic DNA analysis, particularly in cases where standard autosomal DNA profile is uninformative. Y-STR loci are useful markers to identify males and male lineages in forensic practice. In order to achieve rapid and fully integrated detection ofY-STR loci, this study constructed the RTyper Y27 microfluidic chip rapid detection system and validated the performance of this system. MethodsThe system was verified and evaluated by sensitivity, success rate, typing accuracy, peak height balance, sizing precision and accuracy, mock case sample tests, mixture detection ability, and inhibition tolerance. ResultsComplete Y-STR profiles can be obtained when the template amount of DNA standard 9948 was ≥8 ng, the number of blood cards was ≥3 pieces, and the number of oral swab scrapings was≥7 times. The success rate of fully integrated detection was 91.52%, and the concordance rates was 99.74% for 165 testing samples. The success rate of 115 blood spots in these samples was 90.43%, with a typing accuracy of 99.65%, the success rate of 50 buccal swabs was 94%, with a typing accuracy of 99.92%. There was no significant difference in typing accuracy between blood spots and buccal swab samples. The peak height ratio between different fluorescence channels was 89.81%. The standard deviation of allelic ladder for 10 runs was within 0.5 bp. The size differences between allele and corresponding allele in allelic ladder was within 0.5 bp. The maximum precision CV values within and between batches were 0.48% and 0.68%, respectively, which were lower than 15%. These data indicate that the system has good accuracy and precision. The system was capable of accurately typing oral swabs, blood cards, saliva cards, cigarette butts, blood swabs and seminal stains. Complete Y-STR profiles can be obtained and distinguish at the 1∶3 ratio of minor and major contributors in artificial male DNA mixtures. Complete Y-STR genotyping can be obtained under the interference of inhibitors, such as different concentrations of humic acid (50-400 mg/L), indigotin (20-100 nmol/L) and hemoglobin (100-500 μmol/L). ConclusionIn this study, the RTyper Y27 microfluidic chip rapid amplification system is combined with the Quick TargSeq 1.0 integrated system, and the Y-STR profile can be obtained in approximately 2 h. Through a series of verification experiments, the results show that the system has good repeatability, accuracy and stability, can meet the on-site Y-STR detection requirements, and can be used in forensic practice.
8.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
9.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
10.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.

Result Analysis
Print
Save
E-mail