1.Genotoxicity of Liquid Formaldehyde on Brain Cells of Goldfishs
Zhongzhen LI ; Ling LI ; Liming WANG ; Shumao DING ; Xu YANG
Journal of Medical Research 2006;0(03):-
Objective To explore theDNA damage of brain cells of goldfishs through formaldehyde exposure.Methods The goldfishs were treated with liquid formaldehyde at different concentrations(0.01 mmol/L,0.1 mmol/L和1mmol/L)for three days.Single cell gelelectrophoresis technique(comet assay)was used to test the DNA damage of the brain cells.Results Formaldehyde caused significant DNA strand break at the concentration of 0.01mmol/L,0.1mmol/L and 1.0mmol/L.Conclusions Formaldehyde was both a DNA strand breaker when the concentration is higher,it may cause crosslinkagent to the brain in vivo.
2.Effects of atorvastatin on treatment of patients with non-alcoholic fatty liver disease
Wei LIU ; Lianfeng ZHANG ; Jiansheng LI ; Zhongzhen WANG
Chinese Journal of Digestion 2009;29(10):679-681
Objective To evaluate the efficacy and safety of atorvastatin in treatment of patients with non-alcoholic fatty liver disease(NAFLD).Methods Of 72 patients with NAFLD6,8 patients with elevated alanine transaminase(ALT)and cholesterol levels at baseline had completed the study.The patients were randomly divided into treatment trial group(n=38)and control group(n=30,ithout any treatment).The patients in trial group were orally received 10 or 20 mg of atorvastatin daily according to basal serum cholesterol levels being≤or>6.5 mmol/L,respectively.The parameters including body mass index,serum cholesterol level and ALT level were tested and liver density was assessed by echography at baseline and 6 months after treatment.Results There was a significant difference in syndrome scores between baseline and 6 months after treatment[(11.05±1.29)vs.(6.08±0.87)]in trial group(t=1.96,P<0.05).Six months after treatment,11 patients in trial group were presented with normal ALT levels.whereas only 2 patients in control group had normal ALT levels (P<0.05).There was a significant differenee in cholesterol level between baseline and 6 months after treatment[(6.6±0.54)ramol/L vs.(5.4±0.5)mmol/L]in trial group(t=1.72,P<0.05).In addition,there was no differenee in body mass index between baseline and 6 months after treatment both in rial group[(26.8±2.9)kg/m~2 vs.(26.4±2.8)kg/m~2]and control group[(26.5±2.3)kg/m~2 vs.(26.4±2.2)kg/m2~](P>0.05).There was no significant difference in liver density of two groups before and after treatment(P>0.05).No side effect was reported.Conclusions Serum ALT and cholesterol levels are reduced significantly in all patients treated with atorvastatin.It is effective and safe for atorvastatin in treating NAFLD patients with hypercholesterolemia.
3.The reasons of focal liver lesions that difficult to detect by conventional ultrasound analysed by ultrasound-CT/MR fusion imaging
Shufang YUAN ; Kai LI ; Rongqin ZHENG ; Zhongzhen SU ; Erjiao XU
Chinese Journal of Ultrasonography 2014;23(3):235-238
Objective To analyze the reasons of focal liver lesions that difficult to detect by conventional ultrasound ultrasound-CT/MR fusion imaging.Methods 101 lesions which were confirmed by pathology or clinical diagnosis standards were recruited in the research.All of them were difficult to detect by conventional ultrasound but CT/MR display clearly.Ultrasound-CT/MR fusion imaging was used to observe the size,location and internal echo of the lesions,as well as the background of the surrounding liver parenchyma.Results All cases were successfully registrated,the registration time were 2-6min [(4.1 ±0.6)min].For these 101 lesions,93.1%(94/101) of which the diameter ≤20 mm,56.4% (57/101) were located in hepatic segments near the diaphragm (such as S2,S4,S7,S8),78.2% (79/101) were internal isoecho,and 79.2%(80/101) in the background of liver cirrhosis.Conclusions The important reasons that focal liver lesions detected difficult by conventional ultrasound includes:lesion size,location,internal echo and the hepatic background.
4.DC loaded with CPP-Id increase the efficiency of CTL proliferation and enhance its cytotoxicity in vitro
Jianhua CHANG ; Yanxia SHI ; Jin LI ; Xiaoshi ZHANG ; Zhongzhen GUAN
China Oncology 2006;0(12):-
Background and purpose:Dendritic cells(DCs) possess specialized feature such as pathogen recognition,antigen capturing and processing machinery,and stimulating naive T lymphocyte to have antitumor ability that allow them to act like professional APCs.This paper is aimed to confirm the impacts on the proliferation and secretion of INF-? of tumor specific CTL and its cytotoxocity induced by DC loaded with different antigen.Methods:After the stimulation of DC loaded with different antigen,the proliferative rate of allolymphocytes was measured by MTT and the cytotoxocity of CTL was evaluated with LDH method.The INF-? secreted by activated T lymphocytes was detected by ELISPOT.Results:The DC loaded with CPP-Id(320%?15%) had significantly induce T lymphocyte proliferating when comparing with the induction by DC loaded with Id(57%?10%)(P
5.The clinical value of artificial pleural effusion for percutaneous microwave ablation of liver cancer in the hepatic dome
Aohua ZHANG ; Jing XU ; Kai LI ; Zhongzhen SU
The Journal of Practical Medicine 2014;(18):2961-2963
Objective To evaluate the clinical value of artificial pleural effusion for percutaneous microwave ablation of liver cancer in the hepatic dome. Methods 28 difficult cases (total 34 lesions), all lesions were located in the hepatic dome and covered by lung. Infused with artificial pleural effusion by ultrasound real-time monitoring before percutaneous ultrasound-guided microwave ablation. The amount of artificial pleural effusion, the technique successful rate,the rate of lesions revealed, local treatment response and complications had been observed. Results The amount of artificial pleural effusionwas 200-1 000 mL [(388 ± 107)mL]. The technique successul rate of artificial pleural effusion was 100% (28 / 28), the rate of lesions revealed was 85.3%(29 / 34), the other 5 isoechoic lesions were revealed by contrast-enhanced ultrasound. All the 34 lesions was ablated completely, the complete ablation rate was 100%(34 / 34). the rate of complications was 2.9%(1 / 34), 1 patient was found a small amount of intraperitoneal hemorrhage after ablation. Conclusions Artificial pleural effusion assisted percutaneous microwave ablation of liver cancer in the hepatic dome is a safe , effective treatment, it broadened the percutaneous microwave ablation therapeutic range, and should be more widely used in clinically.
6.Comparison study of 3DUS-US and CT-US image fusion technology based on electromagnetic positioning
Liujun LI ; Xuqi HE ; Rongqin ZHENG ; Kai LI ; Erjiao XU ; Peishan GUAN ; Zhongzhen SU
Chinese Journal of Ultrasonography 2015;(9):805-808
Objective To compare the accuracy,convenience and repeatability of 3DUS-US and CT-US image fusion technology based on electromagnetic positioning.Methods A tissue-mimicking phantom was established and used to obtain ultrasound or CT volume images.Two different operators performed 3DUS-US and CT-US image fusion and repeated 10 times,respectively.The success rate,the registration error distance and fusion time of two techniques were recorded and compared between the different operators.Results The ultrasound and CT images of the phantom and its stability could meet the demands of this experiment.3DUS-US and CT-US image fusions were successful.The registration error distance of 3DUS-US image fusion was (1 .70 ± 0.42)mm and fusion time was (76.00 ± 9.99)s,they were obviously superior to CT-US (P = 0.014,P < 0.001 ).There were no significant differences between the two operators in the registration error distance and fusion time of 3DUS-US (P =0.508,P =0.5 1 7).But the registration error distance of CT-US image fusion in experienced operator was lower than the junior (P =0.009),and fusion time had not statistical difference between the two operators (P =0.234).Conclusions The technique of 3DUS-US automatic image fusion based on electromagnetic positioning has advantages of convenience and no experiential dependence comparing with CT-US in the phantom experiments,so it is worthy of being widely popularized in clinical application.
7.A preliminary study of three-dimensional ultrasound images automatic registration based on hepatic vessel
Zhongzhen SU ; Liujun LI ; Kai LI ; Erjiao XU ; Jue WANG ; Rongqin ZHENG
Chinese Journal of Ultrasonography 2014;23(10):865-868
Objective To evaluate the feasibility and accuracy of three-dimensional ultrasound (3DUS) automatic image fusion based on hepatic vessel in clinical application.Methods Forty pairs of 3D ultrasound volumetric images from 10 healthy volunteers were acquired and enrolled in the study,including 10 pairs of each following lobe of the liver:left lateral lobe,left medial lobe,right anterior lobe and right posterior lobe.3DUS automatic registrations were performed based on hepatic vessel.The technical successful rate and accuracy of the image fusion using the 3DUS data from four hepatic lobes were observed and compared.Results Thirty-six pairs of volumetric data were successfully fused together by automatic registration.The technical successful rate was 90% (36/40) and the registration error distance was 1.48 mm (0.98-2.76 mm).There were no statistical differences in the successful rate for the four different hepatic lobes (P =0.891),but the registration error of right anterior lobe was less than left lateral lobe of liver (P =0.014).Conclusions The new technology of 3DUS automatic registration based on hepatic vessel was feasible and reliable,and it has a wide prospect in future clinical application.
8.Planning of the hepatocellular carcinoma's ablation by three-dimensional ultrasound:a preliminary study
Peishan GUAN ; Kai LI ; Rongqin ZHENG ; Liujun LI ; Zhongzhen SU ; Erjiao XU ; Jue WANG
Chinese Journal of Ultrasonography 2015;(5):407-411
Objective To discusse the feasibility and application value of the computer-assisted liver cancer ablation planning based on the three dimensional ultrasound.Methods Forty three-dimensional ultrasound images of 39 patients with 40 tumors'maximum diameter between 21 to 70 mm were collected and then acquired image segmentation and visualzation.The computer-assisted liver cancer ablation planning based on three dimensional ultrasound was comparied with the artificial ablation planning based on two dimensional ultrasound to find out the differences in the success rate,damage rate,time-consuming and the number of insertions between these two methods.Results Compared with the artificial ablation planning based on two dimensional ultrasound,the computer-assisted liver cancer ablation planning had a higher success rate(92.31% vs 53.85%,P =0.000),lower damage rate(7.50% vs 25.00%,P =0.034),shorter time-consuming(44.0 s vs 263.0 s,P =0.000)and less insersion times(3 vs 4,P =0.009).Conclusions The computer-assisted liver cancer ablation planning based on three dimensional ultrasound is more efficient and safety than the traditional way.
9.Experimental study of 3DUS-US single-modality automatic image fusion technology based on electromagnetic positioning
Liujun LI ; Xuqi HE ; Erjiao XU ; Kai LI ; Jiaxin CHEN ; Rongqin ZHENG ; Zhongzhen SU
Chinese Journal of Ultrasonography 2015;(7):618-621
Objective To evaluate the feasibility and accuracy of three-dimensional ultrasound-ultrasound (3DUS-US)automatic image fusion technology based on electromagnetic positioning.Methods The experimental phantom was constructed to acquire ultrasonic images by agarose gel and additives,which was used as the experimental object.3DUS imaging with free-hand and real-time ultrasound imaging automatic registrations were performed based on electromagnetic positioning.To investigate the effect of 3DUS-US image fusion under different scanning speed by free-hand,the fast and slow groups were designed. In addition,a junior operator and a senior operator performed 3DUS-US automatic registrations,and recorded the operating time and registration error,respectively.The repeatability between two operators was analyzed.Results The macroscopic appearance,stability and ultrasonic image of the phantom met the demand of this research.The success rate of 3DUS-US automatic image fusion technology was 100%(40/40).The slow group's registration error distance was (1 .44 ± 0.64)mm,which was obviously lower than the fast group's (2.56±0.53)mm,the difference was statistically significant (P <0.001).There were no statistically differences of the registration error and operating time between the two operators (P =0.508,P = 0.5 1 7 ).Conclusions The technology of 3DUS-US automatic registration based on electromagnetic positioning was feasible and accurate,which is worth applying into the clinical treatment.
10.Biopsy guided by ultrasound intellectual position technique: a phantom study
Xuqi HE ; Kai LI ; Rongqin ZHENG ; Xinling ZHANG ; Zhongzhen SU ; Erjiao XU
Chinese Journal of Ultrasonography 2012;21(9):811-814
Objective To demonstrate the feasibility and accuracy of the intellectual position(IP)technique used in ultrasound-guided biopsy.Methods Several red spheres,which were 10 mm in diameter and visible in ultrasound,randomly placed in the tissue mimicking gel phantom.The biopsy was performed by two operators respectively.Each operator chose 25 spheres,each of which were performed biopsy guided by IP technique,free-hand ultrasound and ultrasound with guide bracket.The red dye in the biopsied sample meant successful performance.The time spend in per biopsy target,the success rate of biopsy and the length of the red dyed sample of the three methods were recorded,and comparison was made among them.Results The median time took in biopsy guided by IP technique was 95(rang,80-110)s,which was longer than that of free-hand ultrasound-guide[30 (rang,22-42) s,P <0.001] and ultrasound-guide with bracket [20(rang,15-28)s,P <0.001].The success rate of biopsy guided by IP technique was 98.0% (49/50)which was as well as that guided by ultrasound-guide with bracket(96.0%,48/50,P =0.558),better than free-hand ultrasound-guide(78.0%,39/50,P =0.002).The median length of red dyed sample biopsied guided by IP technique was 8.0 (rang,7.0-8.5)mm,which was longer than that of free-hand ultrasoundguide[6.0(rang,4.0-8.0)mm,P =0.003] and ultrasound-guide with bracket[7.0(rang,6.0-8.0)mm,P =0.003].There was no statistically difference between the two operators in length of red dyed sample and success rate of biopsy guided by IP technique(P >0.05).Conclusions Biopsy guided by IP technique is a feasible and accuracy method,which will become an effectively supplement of the ultrasound-guide with bracket.