1.Synthesis and surface modification of magnetic silica micro-spheres and Its application in biomedicine
Tao HAN ; Qingping XIAO ; Zhongrong SONG
International Journal of Biomedical Engineering 2010;33(2):125-封3
Magnetic silica micro-spheres is a kind of novel functional materials, which is expected to be applied to targeted drug delivery, immunomagnetic beads, separation of nucleic acid and protein, immobilization of enzymes and isolation and purification of natural products in biomedicine. This review describes the methods of synthesis, surface modification and applications of magnetic silica micro-spheres, which focus on the various strategies in synthesis with core-shell and mosaic structure, sol-gel method, liquid phase deposition, self-assembly technique and micro-emulsion method. Finally, foregroud and prospect of the research are also discussed.
2.Effects of imidapril on blood gas, oxidative stress and inflammatory fac-tors in rats with acute lung injury induced by ammonium chloride
Congfu HUANG ; Xueqin HAO ; Wen DENG ; Chuanfa LIU ; Tingting WANG ; Xiaoli WEN ; Zhongrong TAO
Chinese Journal of Pathophysiology 2016;32(2):278-283
AIM:In this study, the rat lung injury model was induced by ammonium chloride for studying the effect of imidapril on blood gas, serum TNF-α, IL-6 and MDA concentrations, and AngⅡand CD54 protein expression in rat lung tissue.METHODS:Male rats were randomly divided into 3 groups:control group, lung injury model group and drug group.The rats in control group were given saline (2 mL/kg), while the rats in lung injury model group were given 6% ammonium chloride (2 mL/kg).In drug group, imidapril (3 mg· kg-1· d-1) was given to the rats once daily for 1 week by intragastric gavage after given 6%ammonium chloride.On the 7th day, the rats were anesthetized with 2% so-dium pentobarbital.Abdominal aorta blood, venous blood and lung tissue were collected.The blood gas indexes and serum TNF-α, IL-6 and MDA concentrations were determined.The lung tissues were fixed and sliced, and the expression of AngⅡ and CD54 proteins was detected by immunohistochemistry.RESULTS: The PaCO2 increased in lung injury model group compared with control group and drug group (P<0.05).The expression of AngⅡand CD54, and the concentrations of TNF-α, IL-6 and MDA also increased significantly ( P<0.01) in model group.Pulmonary edema, inflammation, alveo-lus congestion, hemorrhage and hyperplasia in model group were obvious compared with control group and drug group. CONCLUSION:Imidapril improves blood gas indexes, and reduces lipid peroxidation and inflammatory responses in the rats with lung injury induced by ammonium chloride.
3.Investigation of the delayed time and post-processing methods of MSCT mesenteric venography
Zhongrong WEI ; Dan HAN ; Tao CHEN ; Ningna YANG ; Chuanmei CHEN ; Mei YANG
Journal of Practical Radiology 2016;32(10):1605-1608
Objective To explore the suitable delayed time of MSCT mesenteric venography and to probe the value of different post-processing methods.Methods 49 patients with abdominal pain (group A)underwent MSCT mesenteric venography with a delayed time of 15-20 s after the arterial phase,and the CT showed the mesenteric vein(MV)was normal.Meanwhile,other 49 ones with abdominal pain (group B)underwent conventional biphasic CT with a delay-time of 35 s after arterial phase.The CT value and diameter of superior mesenteric vein between two groups were compared,and the grading,scoring and display of mesenteric vein with different post-processingmethods were assessed.Results The diameters of SMV were (10.52±2.19)mm in group A and (9.88±2.60)mm in group B,exhibiting no statistically significant difference (P >0.05);Meanwhile the average attenuations of SMV were (1 96.55±40.59)HU in group A and (1 64.32± 28.35)HU in group B,exhibiting a statistically significant difference (P<0.05).In addition,the display ability and scoring of mesenteric vein and its branches on volume rendering (VR)in group A were better than those in group B (P <0.05).VR was better in display of the vascular space distribution than maximum intensity projection (MIP)and sliding thin slab maximum intensity projection (STS-MIP),the STS-MIP was better in display of tiny blood vessels than VR and MIP,and the curved planner reformation (CPR)was superior in display of vascular lumen and the relationship with adjacent structures.Conclusion The image quality of mesenteric vein with the delayed time of 1 5-20 s after arterial phase is superior to that with delayed time of 35 s,and different advantages of the post-processing methods are showed in display of MV.