1.Imaging features of arrhythmogenic right ventricular dysplasia: report of 2 cases and review of the literature
Journal of Chongqing Medical University 2007;0(12):-
Objective:To evaluate the echocardiography and magnetic resonance imaging (MRI) appearances of arrhythmogenic right ventricular cardiomyopathy /dysplasia (ARVC,ARVD) in order to improve the recognition. Methods:Detailed echocardio- grams and MRI were performed in two patients who fulfilled the criteria of the Task Force of the European Society of Cardiol- ogy and International Society and Federation of Cardiology(ESC/ISFC) for ARVD diagnosis,Right ventricular(RV) chamber di- mensions, RV function, and the presence of morphologic ahnormalities were assesed. The patients underwent detailed electro- physiological evaluation and RV bipolar electrogram voltage mapping;radiofrequency ahlation was performed as linear lesions in conjunction with simultaneous CARTO-guided catheter mapping. Results:The RV dimensions were significantly increased;focal RV localized aneurysm and hyper-reflctive moderator band were present in hoth two patients with echocardiograms. RV en- largement and trabecular derangement also were suggested by MRI. The area of abnormality suggested by images and elec- troanstomic voltage mapping were identical. Results:Noninvasive detection of RV structural alterations and functional changes in ARVD is possible by echocardiography and MRI,and these changes may be used as the major criteria for the diagnosis of ARVD.
2.Study of the degree in white matter structural networks in the glioma based on diffusion tensor tractography.
Weizhou ZHU ; Ling TAO ; Zhiyu QIAN ; Chuanjian XU
Journal of Biomedical Engineering 2013;30(6):1309-1314
At present, an effective detecting method for brain function impairment for the patients with the glioma is urgently needed in clinic, because it may help us understand its pathogenesis. This paper proposes a method of combining diffusion tensor tracing technology and 'small world' network. It utilizes the degree of brain function network to study complex network topological properties of the patients with the glioma in temporal lobe area. The experimental results showed that the brain networks of the patients with the glioma of different grades were destroyed compared with those of the normal persons, but the destruction degree is independent of the tumor grades. The distribution of functional connections is index truncated power-law accompanied by significant heterogeneity. Meanwhile, the stronger functional areas of information in the glioma have transferred and there exists lack of language function area and sensory function area.
Brain
;
physiopathology
;
Diffusion Tensor Imaging
;
Glioma
;
pathology
;
Humans
;
White Matter
;
pathology
3.Study on navigation path correction in neuro-navigation based on near infrared spectroscopy.
Xiaofen ZHU ; Ling TAO ; Zhiyu QIAN
Journal of Biomedical Engineering 2010;27(4):887-892
At present, navigation path deviation caused by brain shift is the main factor that affects the accuracy of neurosurgical navigation. A new method of near infrared spectroscopy (NIRS) based neurosurgical navigation is presented in the paper. The correlation between NIRS optical parameters and medical image is used and the gray information of navigation path is regarded as the priori knowledge, sample-points curvatures are calculated by Hermite interpolation and the Mean Hausdorff distance as measurement criterion is used to match feature segments, then the real-time correction model is established. The algorithm of the given model is simple and can realize the best match within the error, it provides an effective method for real-time navigation path correction.
Algorithms
;
Artificial Intelligence
;
Calibration
;
Humans
;
Image Interpretation, Computer-Assisted
;
methods
;
Neuronavigation
;
methods
;
Spectroscopy, Near-Infrared
;
methods
;
Surgery, Computer-Assisted
;
methods
4.An improved medical image fusion algorithm and quality evaluation.
Meiling CHEN ; Ling TAO ; Zhiyu QIAN
Journal of Biomedical Engineering 2009;26(4):711-715
Medical image fusion is of very important value for application in medical image analysis and diagnosis. In this paper, the conventional method of wavelet fusion is improved,so a new algorithm of medical image fusion is presented and the high frequency and low frequency coefficients are studied respectively. When high frequency coefficients are chosen, the regional edge intensities of each sub-image are calculated to realize adaptive fusion. The choice of low frequency coefficient is based on the edges of images, so that the fused image preserves all useful information and appears more distinctly. We apply the conventional and the improved fusion algorithms based on wavelet transform to fuse two images of human body and also evaluate the fusion results through a quality evaluation method. Experimental results show that this algorithm can effectively retain the details of information on original images and enhance their edge and texture features. This new algorithm is better than the conventional fusion algorithm based on wavelet transform.
Algorithms
;
Artificial Intelligence
;
Diagnostic Imaging
;
methods
;
Humans
;
Image Enhancement
;
methods
;
Image Interpretation, Computer-Assisted
;
methods
;
Image Processing, Computer-Assisted
;
methods
;
Magnetic Resonance Imaging
;
methods
;
Pattern Recognition, Automated
;
methods
;
Positron-Emission Tomography
;
methods
;
Tomography, X-Ray Computed
;
methods
5.Transvenous Cryoablation Versus Radiofrequency Catheter Ablation for Treatment of Atrioventricular Nodal Reentrant Rachycardia
Linzhi LI ; Zhiyu LING ; Zengzhang LIU ; Li SU ; Qiang SHE ; Yuehui YIN
Chinese Circulation Journal 2009;24(3):206-209
Objective:To compare the efficacy and safety between cryoablation(Cryo)and radiofrequency (RF)ablation in patients with atrioventricular nodal reentrant tachycardia(AVNRT). Methods: A total of 83 patients with AVNRT underwent electrophysiological treatment in our hospital from October 2006 to March 2009 were studied. Patients were divided into two groups according to their own choices. Cryo group (n=41) and RF group (n=42). The clinical characteristics,success rate,procedural time and ablative time were compared between two groups. Results:The procedural time and ablative time in Cryo group was significantly longer than those in RF group (119.14±40.16 min vs.85.86±28.24 min,P=0.001; 1118.91±620.62 s vs.370.97±279.23 s,P<0.001). The acute success rate was achieved in 40/41(97.6%)patients in Cryo group,and 42/42(100.0%) in RF group. Transient AV-block was encountered in 6 (15%) patients in the Cryo group and 5 (11.9%) in RF group (P=0.681). There was no complete atrial-ventricular(AV)conduction block at the end of procedures. There was no recurrence of AVNRT in either Cryo group nor in RF group during 11.6±5.5 months of follow up period.Conclusion:Cryoablation was as effective and safe as RF ablation for AVNRT. Cryo-energy was one kind of alternative ablation energy for AVNRT.
6.Bioeffects of canine myocardium under microbubble destruction via diversity of ultrasonic intension
Shigen ZHONG ; Zhigang WANG ; Zhiyu LING ; Yuehui YIN ; Qiao LI ; Jie LUO ; Xingsheng LI
Chinese Journal of Medical Imaging Technology 2009;25(10):1738-1740
Objective To explore the bioeffects of canine myocardium under microbubble destruction via diversity of ultrasonic intension, in order to optimize ultrasonic intension for experiments. Methods Nine mongrel dogs were randomly divided into 3 groups. Ultrasound (1 MHz) in diversity of different intension (0.5 W/cm~2, 1.0 W/cm~2, 2.0 W/cm~2) was applied to expose canine myocardium after intravenous injection microbubbles of 2.0 ml. All the dogs were killed after being exposed for 5 min. The myocardium was harvested for HE staining and observed with transmission electron microscope for the tissue microstructures. Results The myocardium of hyperemia, disfiguration and necrosis wer observed in all groups. Myocardial edema but not hemorrhage appeared with 0.5 W/cm~2 , mild myocardial hemorrhage and slight inflammatory cell infiltration happened with 1.0 W/cm~2, whereas obvious hemorrhage and certain degree of inflammatory cell infiltration occurred with intension of 2.0 W/cm~2. With the augmentation of ultrasonic intension, myocardium trend to aggravate. Conclusion Ultrasound of diversity intension can induce different bioeffects of canine myocardium. Ultrasound mediated microbubble destruction with the intensity of 1.0-2.0 W/cm~2 can provoke a certain degree of inflammatory reaction with mild myocardial damage.
7.Effects of poly lacticoglycolic acid ultrasound contrast agent on tumor lymph node imaging
Yuanyi ZHENG ; Zhigang WANG ; Haitao RAN ; Xiaodong LI ; Qunxia ZHANG ; Chunjiang YANG ; Anguo LUO ; Xiangxiang JING ; Zhiyu LING ; Hong REN ; Lili DAI
Chinese Journal of Ultrasonography 1993;0(01):-
Objective To study the effects of poly lacticoglycolic acid(PLGA) ultrasound contrast agent on tumor lymph node imaging and its mechanism.Methods PLGA ultrasound contrast agent was made by double emulsion method; VX2 tumor cells were harvested from carrier rabbits and inoculated in the thigh of healthy New Zealand White rabbits. Implants were allowed to grow for 14 to 18 days before imaging. Popliteal lymph nodes were imaged as the injection sites were massaged. And macrophages were used to investigate the mechanism for lymph node enhancement. Results PLGA ultrasound contrast agent had a tight size distribution. Tumor lymph node was significantly enhanced by PLGA ultrasound contrast agent. Macrophages experiment showed that macrophages could phagocyte lots of PLGA ultrasound contrast agents.Conclusions PLGA ultrasound contrast agent is good for lymph node imaging. The possible mechanism for lymph node enhancement is that macrophages in lymph node can phagocyte lots of PLGA contrast agents, which causes the concentration of PLGA contrast agent in lymph node.
8.Assessment of early intima elasticity of carotid by ultrasonic technology of layer-specific strain combined with serum complement C3 in systemic lupus erythematosus
Ling LUO ; Lixue YIN ; Zhiyu GUO ; Yun XU ; Sijia WANG
Chinese Journal of Ultrasonography 2018;27(12):1030-1035
Objective To reveal the early elastic dysfunction of common carotid artery may have occurred in systemic lupus erythematosus( SLE) patients ,the circumferential strain parameters of common carotid artery intima in SLE patients at different serum complement levels were quantitatively evaluated by layer-specific strain imaging . Methods Seventy-two patients suffered from SLE without evidence of atherosclerosis were enrolled ,and the results of laboratory examination of serum complement C 3 in patients with SLE were recorded in detail ,49 cases of SLE patients whose serum C3 was lower than the normal reference range(SLE C3+ group) ,23 cases of SLE patients whose serum C3 was in the range of normal reference value(SLE C3 - group) . And a matched healthy control group ( n =38) were selected . Carotid ultrasound were performed in all three groups ,and the common carotid artery conventional parameters ,such as common carotid artery intima-media thickness ( CCA-IM T ) ,peak systolic velocity ( PSV ) ,end-diastolic velocity(EDV) ,resistance index(RI) and circumferential strain related parameters ,such as circumferential strain of common carotid artery intima(CSendo) and circumferential strain rate(CSr) were measured and derived.Therelatedparametersamongthosegroupswerecomparedfordifference.Results ①Therewas no significant difference in RI among the three groups(all P >0 .05) . The values of CCA-IMT in the SLE C3+ group and SLE C3- group were larger than that in the control group( all P <0 .05) . ②The values of CSendo and CSr in the SLE C3+ group and SLE C3 - group were lower than those in the control group ,the values of SLE C3+ group were significantly lower than those in the control group ( P <0 .001) ,and there was no significant difference between the SLE C3- group and control group( P >0 .05) . ③The CSendo and CSr in the SLE C3+ group were lower than those in the SLE C3- group(all P < 0 .05) . Conclusions CSendo which is provided by new ultrasonic technology of layer-specific strain combined with recent changes in serum complement C3 may provide visual evidence for assessing early elastic disfunction of carotid intima in SLE patients .
9.Visualization and quantification of myocardial mechanical changes of left ventricle in systemic lupus erythematosus patients using ultrasonic layer‐specific strain imaging
Ling LUO ; Lixue YIN ; Zhiyu GUO
Chinese Journal of Ultrasonography 2019;28(7):581-587
Objective To evaluate the damage of longitudinal mechanical parameters of left ventricular myocardium by ultrasonic layer‐specific strain imaging in patients with systemic lupus erythematosus ( SLE ) without conventional evidence of cardiovascular system involvement . Methods Seventy‐eight patients suffered from SLE without conventional evidence of cardiovascular system involvement ( SLE group ) and 48 healthy volunteers with age and sex matched ( control group ) were selected for this study . T he left ventricular conventional structure and functional parameters were measured by conventional echocardiography . T hen layer‐specific strain imaging was performed in both groups to obtain left ventricular endocardial myocardial global longitudinal strain ( GLSendo ) ,mid‐myocardial GLS ( GLSmid) ,epicardial GLS ( GLSepi) and basal segment ,middle segment and apex longitudinal strain ( LS) of all three layers of the myocardium . T hen the transmural difference of the GLS ( ΔLS = GLSendo -GLSepi) were calculated . T he related parameters between these two groups were compared for difference and correlation analysis of related mechanical parameters were also made . Results ① T here was no significant difference in the left ventricular ejection fraction ( LVEF ) and left ventricular stroke volume ( LVSV ) between the two groups ( all P >0 .05 ) ; Compared with the control group ,the mean E/e in the SLE group was increased and the E/A ,E ,e were decreased ( all P <0 .05) ; however ,the incidence of left ventricular diastolic dysfunction in the SLE group ( 2/78 ) was not significantly different from that in the control group ( 0/48 ) ( P >0 .05 ) . ② T he myocardial global longitudinal strain( GLS ) of the two groups were decreased from endocardial to epicardial gradient ; the values of GLS and segmental LS of all three layers in the SLE group were decreased ( all P <0 .05) ; the ΔLS of the SLE group was decreased compared with the control group ( P < 0 .05 ) ; the value of peak strain dispersion ( PSD ) were increased in SLE patients ( P < 0 .05 ) . ③ T he correlation analysis showed the GLS of each layer of myocardium in SLE patients were negatively correlated with disease duration ( rs = -0 .34~ -0 .36 ,all P < 0 .05 ) and SLE disease activity index ( SLEDAI) ( rs = -0 .25~ -0 .30 ,all P <0 .05 ) . Conclusions T he ultrasonic layer‐specific strain imaging can quantitatively detect the damage of mechanical parameters of left ventricle in SLE patients ,w hich is more sensitive than the conventional echocardiography in evaluating left ventricular systolic function . It may provide visual evidence for early diagnosis of cardica dysfunction in SLE patients .
10.Factors related to false negative results of interferon-γ release test in patients with confirmed pulmonary tuberculosis
Ling YE ; Jianhua LAN ; Min FANG ; Shun WANG ; Zhiyu WU ; Shugen WU ; Chunxian PENG ; Weili LU ; Tao LU
Chinese Journal of Clinical Infectious Diseases 2022;15(6):454-458
Objective:To analyze the influencing factors related to false-negative results of interferon-γ release assay (IGRA) QFT-GIT in patients with confirmed pulmonary tuberculosis.Methods:Clinical data of 389 patients with bacteriologically confirmed pulmonary tuberculosis who underwent QFT-GIT in Quzhou Hospital Affiliated to Wenzhou Medical University between January 1 and December 31 2020 were retrospectively analyzed. Univariate and multivariate logistic regression were used to analyze the influencing factors related to the false-negative results of QFT-GIT.Results:Among 389 confirmed patients, 347 cases had positive QFT-GIT results and 42 cases had negative results. Univariate analysis showed that the false-negative results of QFT-GIT were associated with low BMI, reduced CD4 + T lymphocyte count, decreased lymphocyte count, increased C-reactive protein, negative sputum smear, anemia, diabetes mellitus, malignant tumor and sepsis ( P<0.05 or P<0.01). Multivariate conditional logistic regression analysis showed that BMI <18.5 kg/m 2( OR=1.585, 95% CI 1.076-2.336), complicated with diabetes( OR=5.157, 95% CI 2.340-11.365), malignant tumors ( OR=5.596, 95% CI 2.048-15.295)and sepsis ( OR=4.141, 95% CI 1.042-16.459) were independent risk factors for the false-negative results of QFT-GIT ( P<0.05 or P<0.01). Conclusion:When the pulmonary tuberculosis patients are extreme emaciation, complicated with diabetes, malignant tumor or sepsis, the QFT-GIT results will be false negative.