1.A Study on the Construction of Hidden Curriculum in Colleges and Universities
Yuzhuang HUANG ; Zhiquan BO ; Hongmei CHEN
Chinese Journal of Medical Education Research 2006;0(09):-
The research of curriculum tells us that in every university there are two kinds of curriculums.One is noticeable,the other is hidden.Both of them work for the goal of bringing the students up.The witchery of hidden curriculum is that it affects the students continually and secretly.This essay discuses the significance,principle and approaches of the construction of hidden curriculum in higher learning.
2.Clinical Study on Tuina Therapy for Degenerative Spondylolisthesis of the Lumbar Spine
Zhiquan WANG ; Bo SUN ; Jianhua CHEN ; Yunding WU
Journal of Acupuncture and Tuina Science 2009;7(3):152-155
Objective:There is definite therapeutic effect in tuina treating low back pain.The comparative observation was performed on the two types of tuina manipulation for degenerative lumbar spondylolisthesis,in order to explore the best tuina manipulation for lumbar spondylolisthesis.Methods:All of 121 cases with degenerative lumbar spondylolisthesis were divided into the experimental group and control group randomly by the visit orders and pathological gradations,61 cases in the experimental group,including 34 cases of grade Ⅰ and 27 cases of grade Ⅱ,and 60 in the control group,including 34 cases of grade Ⅰ and 26 cases of grade Ⅱ.There was no significant difference in the general materials of the two groups.Based upon the similar tuina therapy applied on the soft tissues in the two groups,micro-regulating manual technique of the spine was applied in the experimental group,and the hip and knee-flexed and pillow method was applied in the control group.The treatment was given 3 sessions a week,with 10 sessions as one course of the treatments.The therapeutic effects were assessed after one course of the treatments.Results:There was significant difference (P<0.01) in the total effective rate and in the remarkable effective rate and curative rate of the patients with grade Ⅰ between the experimental group and control group,also there was significant difference (P<0.05) in the total effective rate of the patients with grade Ⅱ.Conclusions:The therapeutic effects by the micro-regulatory manual technique are comparatively better for degenerative lumbar spondylolisthesis,and the milder the pathological condition is,the better the therapeutic effects would be.
3.A case of Cryoballoon ablation for persistent atrial fibrillation.
Jian SUN ; Xiangfei FENG ; Pengpai ZHANG ; Jun WANG ; Rui ZHANG ; Zhiquan WANG ; Qiufen LU ; Bo LIU ; Shangbiao LU ; David LAN ; Yigang LI
Chinese Journal of Cardiology 2014;42(4):341-342
Aged
;
Atrial Fibrillation
;
surgery
;
Catheter Ablation
;
methods
;
Humans
;
Male
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Efficacy and safety of LY01005 versus goserelin implant in Chinese patients with prostate cancer: A multicenter, randomized, open-label, phase III, non-inferiority trial.
Chengyuan GU ; Zengjun WANG ; Tianxin LIN ; Zhiyu LIU ; Weiqing HAN ; Xuhui ZHANG ; Chao LIANG ; Hao LIU ; Yang YU ; Zhenzhou XU ; Shuang LIU ; Jingen WANG ; Linghua JIA ; Xin YAO ; Wenfeng LIAO ; Cheng FU ; Zhaohui TAN ; Guohua HE ; Guoxi ZHU ; Rui FAN ; Wenzeng YANG ; Xin CHEN ; Zhizhong LIU ; Liqiang ZHONG ; Benkang SHI ; Degang DING ; Shubo CHEN ; Junli WEI ; Xudong YAO ; Ming CHEN ; Zhanpeng LU ; Qun XIE ; Zhiquan HU ; Yinhuai WANG ; Hongqian GUO ; Tiwu FAN ; Zhaozhao LIANG ; Peng CHEN ; Wei WANG ; Tao XU ; Chunsheng LI ; Jinchun XING ; Hong LIAO ; Dalin HE ; Zhibin WU ; Jiandi YU ; Zhongwen FENG ; Mengxiang YANG ; Qifeng DOU ; Quan ZENG ; Yuanwei LI ; Xin GOU ; Guangchen ZHOU ; Xiaofeng WANG ; Rujian ZHU ; Zhonghua ZHANG ; Bo ZHANG ; Wanlong TAN ; Xueling QU ; Hongliang SUN ; Tianyi GAN ; Dingwei YE
Chinese Medical Journal 2023;136(10):1207-1215
BACKGROUND:
LY01005 (Goserelin acetate sustained-release microsphere injection) is a modified gonadotropin-releasing hormone (GnRH) agonist injected monthly. This phase III trial study aimed to evaluated the efficacy and safety of LY01005 in Chinese patients with prostate cancer.
METHODS:
We conducted a randomized controlled, open-label, non-inferiority trial across 49 sites in China. This study included 290 patients with prostate cancer who received either LY01005 or goserelin implants every 28 days for three injections. The primary efficacy endpoints were the percentage of patients with testosterone suppression ≤50 ng/dL at day 29 and the cumulative probability of testosterone ≤50 ng/dL from day 29 to 85. Non-inferiority was prespecified at a margin of -10%. Secondary endpoints included significant castration (≤20 ng/dL), testosterone surge within 72 h following repeated dosing, and changes in luteinizing hormone, follicle-stimulating hormone, and prostate specific antigen levels.
RESULTS:
On day 29, in the LY01005 and goserelin implant groups, testosterone concentrations fell below medical-castration levels in 99.3% (142/143) and 100% (140/140) of patients, respectively, with a difference of -0.7% (95% confidence interval [CI], -3.9% to 2.0%) between the two groups. The cumulative probabilities of maintaining castration from days 29 to 85 were 99.3% and 97.8%, respectively, with a between-group difference of 1.5% (95% CI, -1.3% to 4.4%). Both results met the criterion for non-inferiority. Secondary endpoints were similar between groups. Both treatments were well-tolerated. LY01005 was associated with fewer injection-site reactions than the goserelin implant (0% vs . 1.4% [2/145]).
CONCLUSION:
LY01005 is as effective as goserelin implants in reducing testosterone to castration levels, with a similar safety profile.
TRIAL REGISTRATION
ClinicalTrials.gov, NCT04563936.
Humans
;
Male
;
Antineoplastic Agents, Hormonal/therapeutic use*
;
East Asian People
;
Gonadotropin-Releasing Hormone/agonists*
;
Goserelin/therapeutic use*
;
Prostate-Specific Antigen
;
Prostatic Neoplasms/drug therapy*
;
Testosterone