1.Reproducibility and influencing factors of 31p MR spectroscopy in rabbit liver with two-dimensional chemical shift imaging
Risheng YU ; Jianzhong SUN ; Wenhong DING ; Xiufang XU ; Zhikang WANG
Chinese Journal of Radiology 2009;43(5):544-550
Objective To investigate the reproducibility and influencing factors of relative quantification of phosphorus metabolites with two-dimensional chemical shift imaging (2D CSI) in rabbit liver. Methods Using 2D CSI MRS, 500 ml phosphate (NaH2PO4) solution phantom with 0. 05 mol/E concentration and one healthy rabbit were scanned 30 times respectively in one day and rescanned 30 times in the next day, and the stability of MR scanner and reproducibility of within-run and between-days in the same individual were analyzed. Each of thirty rabbits was scanned and rescanned one time respectively in different days, and the reproducibility of between-days in one group was analyzed. The data were statistically analyzed with t tests. Results (1) Phosphate solution phantom had a good reproducibility of within-run with the coefficient variation (CV) of 4. 92% and 5. 12% respectively in different two days. No significant change of phosphorus metabolites was detected in between-days, which was 16. 68 ± 0. 82 and 16. 56 ± 0. 85 respectively(t = 0. 665, P > 0. 05 ). (2) The CV of metabolites in one healthy rabbit ranged from 8. 04% to 34. 13%. Among the metabolites, β-ATP had the best reproducibility with the CV less than 10%. PME was 0. 88 ± 0. 28 and 0. 88 ± 0. 30, PDE was 4. 35 ± 0. 66 and 4. 35 ± 0, 66, Pi was 0. 95 ± 0.30 and 0.97±0.28, α-ATP was 5.58±0.60 and 5.61±0.61, β-ATP was 2.70±0.22 and 2.71± 0. 22, γ-ATP was 2. 20±0. 63 and 2. 18±0.44 respectively, no significant changes of metabolites were detected in between-days( P >0. 05 ). (3) The CV of metabolites in 30 healthy rabbits ranged from 8.48% to 36. 21%. Among the metabelites, β-ATP had the best reproducibility with CV less than 10%. PME was 0. 84 ± 0. 30 and 0. 79 ± 0. 28, PDE was 4. 29 ± 0.72 and 3.94 ± 0. 84, Pi was 0. 91 ± 0. 28 and 0. 92 ± 0. 31, α-ATP was 5.65±0. 66 and 5. 36±0. 60, β-ATP was 2. 71±0. 23 and 2. 66±0. 25, γ-ATP was 2. 07±0. 29 and 1.99±0. 37 respectively, no significant changes of metabolites were detected in between-days (P > 0. 05). Conclusions The relative quantification of hepatic β-ATP may be most reliable among the phosphorus metabolites for rabbit liver because of its good reproducibility and small CV. The quantification of phosphorus metabolites by 31p MRS with 2D CSI in rabbit liver is affected by many factors.
2.Best Operation Mode of AP-960 Full-automated ELISA System
Huijun ZHU ; Zhikang XU ; Helu LIU ; Xiaoxing YANG ; Zhenping LIU
Chinese Medical Equipment Journal 1993;0(05):-
Objective To compare the operation modes of AP-960 full automated ELISA system.Methods Two models were tested: beginning with adding specimens(model 1) and beginning with adding enzymes(model 2).The following factors were compared: the consumption of suckers,usage of time,result of test and the usual alarm during the test.Results The consumptions of suckers were 564 and 84 respectively.The needing time of the former mode was 125 minutes and that of the latter mode was 90 minutes.Conclusion The mode beginning with adding enzymes(model 2) is better for the current status of our clinical laboratory.
3.Development and application of network information system for laboratory equipment management
Helu LIU ; Ningzheng LUO ; Zhikang XU ; Zhenping LIU ; Yulin GAO
Chinese Medical Equipment Journal 1989;0(01):-
Objective To develop a set of network information system for laboratory equipment management. Methods According to the requirement of laboratory equipment management provided by laboratory section, a professional laboratory software company developed the software by using SQL Server 2000 as database and Delphi 7.0 as program language. Results Data of laboratory equipment in hospital were shared and communicated. Laboratory equipment management was standardized and work efficiency and quality were improved. Conclusion The software is convenient and practical with high popularization and application value.
4.Study on the mechanism of IL-35 in autoimmune diseases
Xu LIU ; Siyu GONG ; Zhikang TIAN ; Junfeng ZHANG
Chinese Journal of Microbiology and Immunology 2021;41(5):411-416
As an anti-inflammatory factor, Interleukin 35 (IL-35) is composed of p35 subunit and EBI3 subunit. IL-35 plays an important role in many diseases, but many mechanisms are not clear. In recent years, it has been found that IL-35 plays an important immunomodulatory role in autoimmune diseases, such as rheumatoid arthritis, inflammatory bowel disease, psoriasis, idiopathic inflammatory myopathy, systemic lupus erythematosus, multiple sclerosis, type I diabetes, pemphigus and primary biliary cirrhosis, etc. This review summarizes the research progress of the mechanism of IL-35 in the above autoimmune diseases.
5.The study on relationship between energy metabolic changes tested by phosphoras-31 magnetic resonance spectroscopy and the severity of acute hepatic injury
Risheng YU ; Lingnan ZHANG ; Ying CHEN ; Jianzhong SUN ; Xiufang XU ; Zhikang WANG ; Kunyuan XU ; Feng CUI
Chinese Journal of Digestion 2008;28(11):737-741
Objective To study the relationship between energy metabolic changes tested by phosphorus-31 magnetic resonance(MR)spectroscopy(31P MRS)and the liver damage score(LDS)in rabbit models and investigate the diagnostic value of 31P MRS in acute hepatic injury.Methods A total of 30 rabbits were received different radiation dose(ranging from 5 Gy to 20 Gy)to establish acute hepatic injury models.31P MRS was than carried out 24 hrs after radiation.The rabbits were divided into mild(LDS≤3 U),moderate(LDS 3-6 U)and severe(LDS>6 U)hepatie injury groups.Ten healthy rabbits were served as controls.MR examination was performed on a 1.5 T imager using a 1H/31P surface coil by the 2D chemical shift imaging technique.The relative quantification of phosphomonoesters(PME),phosphodiesters (PDE), inorganic phosphate (Pi) and adenosine severe hepatic injury groups were 1.83±0.33,1.55±0.24,1.27±0.07 and 0.98±0.18,respectively,with significant differences(P<0.05).The ATP level was progressively decreased with the increase of severity Of hepatic injury.The relative quantification of PME and Pi were decreased in severe hepatic injury group compared to control group(P<0.05).There was no significant difference higher in moderate(1.94±0.50)and severe(1.96±0.72)hepatic injury groups compared to control group(1.43±0.31)and mild hepatic injury group(1.40+0.38)(P<0.05).No significant difference was found in ratio of relative quantification of other phosphorus metabolites.Conclusions 31P MRS is a useful method in evaluating acute hepatic injury.The relative quantification of hepatic ATP level,which can reflect the severity of acute hepatic injury,is correlated with LDS.
6.Long-term results of the surgical treatment of penile curvature with 16-dot plication : a retrospective analysis of 86 patients
Zhong WANG ; Wenji LI ; Haijun YAO ; Jun DA ; Zhikang CAI ; Yueqing JIANG ; Mingxi XU
Chinese Journal of Urology 2014;35(12):931-935
Objective To assess the long-term surgical outcomes,patient's satisfaction and functional results of correction for patients with penile curvature by 16-dot minimal tension plication.Methods Between August 2004 and December 2010,92 patients with penile curvature underwent surgical correction of penile curvature by 16-dot minimal tension plication.Of them,86 patients (53 patients with congenital penile curvature and 33 patients with Peyronie's disease (PD)) were reached for long-term follow-up.Indications for operation included patients with 30 to 90 degrees of penile curvature,penile length greater than 10 cm and patients who had one or more symptoms,such as difficulty or inability to vaginal penetration and partner discomfort during sexual intercourse.Patients were excluded from study if they had severe penile curvature (greater than 90 degrees),hourglass deformities or large plaques.Preoperative evaluation included international index of erectile function 5 (IIEF-5) questionnaire score,pain on erection and physical examination.Patients were recommended daily low dose phosphodiesterase type 5 (PDE-5) inhibitors 2 weeks after surgery and maintained for 2 to 3 months.At follow-up,recurrence rate,complications,erectile function,patients and partner's satisfaction with the surgery were assessed.Results The mean time of follow-up was 79 months (range,35-107 months).Of 86 patients who had been reached for long-term follow up,82 patients (95.3%) and 77 partners (89.5%) reported overall satisfaction after the surgery.Complete penile straightening was achieved in 79 patients (91.8%).Slight residual curvatures were observed in 7 patients,but did not affect their sexual intercourse.Postoperative penile length shortening (median penile length loss 1.3 cm) was noted in 35 patients (40.7%),which did not affect their sexual intercourse.In addition,no de novo erectile dysfunction was observed,and sexual function was significantly improved evidenced by the IIEF-5 scores,especially in the patients who had received PDE-5 inhibitors for 2 to 3 months.There were no surgery-related complications,such as hematoma,urethral injury,or infection.Conclusion The longterm results demonstrate that correction of penile curvature using 16-dot plication is a simple and safe method to achieve cosmetic and functional satisfaction in patients with mild to moderate penile curvature.
7.Application of Microwave-ELISA Two-Step-Test to Hepatitis-B signs check in factory physical examination
Zhikang XU ; Yu FANG ; Xiaoxing YANG ; Huijun ZHU ; Zhenping LIU ; Zhaojun ZHU
Chinese Medical Equipment Journal 2003;0(10):-
Purpose:To Explore the requirements and accuracy for applying Microwave-ELISA Two-Steps-Test to the factory physical examination.Methods:Do the Microwave-ELISA Two-Steps-Test for 1,128 factory physical examination specimens that need the HBsAg and HBeAg inspection;comparing the result to the conventional ELISA test;and retest the specimens with the HBsAg-positive results.Results:There are 119 HBsAg-positive and 32 HBeAg-positive results for the ELISA test;there are 122 HBsAg-positive and 34 HBeAg-positive results for the microwave test;all the HBsAg-positive results are proved to be positive by using the colloid gold HbsAg rapid testing paper.Conclusion:Microwave-ELISA Two-Steps-Test is timesaving,simple and high sensitive for testing Hepatitis-B signs,which can reduce the hook phenomenon and can be used to do the large number of HBsAg and HBeAg checks in factory physical examinations.It can hasten the result report and greatly improve the efficiency.
8.Data analysis of hearing of 719 recruited students from teenager flying school and discussion of relative standards
Xiaoli MA ; Zhikang ZOU ; Rui GUO ; Xiaobo LIU ; Chunyan WU ; Feng WANG ; Po XU
Military Medical Sciences 2017;41(1):9-11
Objective To analyze the data on hearing of recruited students from a teenager aviation school according to both the standards of PLA and those of the US Armed Forces , to learn about their differences in hearing standards in medi-cal selection, and to raise suggestions on establishing hearing standards for medical selection of flying cadets from teenager aviation schools .Methods The data collected on the first hearing test about hearing of students from Hebei Teenager Aviation School were collected .The validity of the data was determined according to the medical selection standards both of PLA and of the US Armed Forces respectively .The cases of qualified or unqualified recruits at high frequency and middle -low frequency were counted respectively and analyzed statistically .Results The unqualified recruits determined by PLA′s standards tended to be unqualified too when determined by the US Armed Forces standards .During the screening of high frequency hearing and the general hearing condition , the proportion of unqualified cases determined by the US selection standards was higher than that determined by PLA′s selection standard .In the screening of middle-low frequency hearing , no statistically significant difference was found in the proportion of unqualified cases when the two different selection standards were used.Conclusion The hearing standard for medical selection of flying cadets at high frequency in the US Armed Forces is stricter than that in the PLA .Meanwhile, the hearing standard at middle-low frequency in the US Armed Forces is different from that in the PLA , though there are no statistically significant differences in the proportion of unqualified cases.The hearing standards of the US Armed Forces are recommended in recruiting flying cadets for teenager flying schools .
9.Analysis and management of complications caused by holmium laser ureterolithotripsy
Mingxi XU ; Zhong WANG ; Guoqin DONG ; Mujun LU ; Ke ZHANG ; Zhikang CAI ; Yueqing JIANG ; Xiaomin RENG ; Haijun YAO ; Jun DA
International Journal of Surgery 2010;37(5):296-299
Objective To study the the causes, management and preventive measures for complications of holmium laser ureterolithotripsy. Methods Three hundred and seven cases of uteteral calculi from Jan. 2006 to Jan. 2010 were reported (203 men and 104 women, age ranged from 18-83 years,mean age 51.6 years). One hundred thirty-three patients had calculi in the lower ureter,94 in the middle part and 80in the upper ureter. Results The overall comminution rate was 89.9% (276/307 cases). sixteen cases (5.2%) were followed by ESWL due to the shift of the stones to the renal pelvis. The operation failed in 9 cases(2.9%), 3 cases(1%) had perforation,and recoveried after open operation. Deep infection was found in 3(1%)cases,which recoveried after anti-infective therapy. Conclusions Holmium laser ureterolithotripsy is an effective method for treating ureteral calculi, with advantage of high efficiacy,safety and minimal invasion. To master the operating induction, to raise operating technique and to take correct measure could reduce complications effectually.
10.Surface modification of poly methyl methacrylate intraocular lens by alpha-allyl glucoside.
Chao QU ; Ke YAO ; Ruiqiang KOU ; Zhikang XU
Journal of Biomedical Engineering 2004;21(1):115-117
A method for improving the biocompatibility of the intraocular lens (IOL) and reducing the cell attachment was adopted in this study. The alpha-Allyl glucoside was used for the surface modification of the poly methyl methacrylate (PMMA) IOL by way of plasma-induced in situ polymerization. The surfaces of the control and treatment IOLs were characterized by contact angle estimation and ESCA techniques. The resolution, diopter and anti-fatigue of loops were determined by physical and optical methods. Cell attachment on the surfaces was examined by light microscopy. The results indicated that all of the treatment groups had excellent physical and optical properties. The modification with the use of alpha-Allyl glucoside could improve the hydrophilicity of the anterior surface of the PMMA IOLs and reduce the cell attachment.
Allyl Compounds
;
chemistry
;
Biocompatible Materials
;
Glucosides
;
chemistry
;
Lenses, Intraocular
;
Materials Testing
;
Polymerization
;
Polymethyl Methacrylate
;
chemistry
;
Surface Properties