1.Application of cerebral protection devices in carotid artery stenting
Huan ZHANG ; Fuxian ZHANG ; Zhijun WENG
International Journal of Surgery 2009;36(2):119-122
Carotid artery stenosis is one of the most important reasons for stroke. Carotid artery stenting possesses more advantages with less damage and pain for patients, which has becaome the most effective treatment for carotid artery stensis, and the use of review the issues related to te carotid artery stenting under cerebral protection. With the accomplishment of many successful large scale clinical trials carried out by multiple centers, it is believed that carotid artery stenting with cerebral protection plays important orle in the prevevtion and treatment of cerebral stroke initiated by carotid artery stenosis.
2.Application of anastomat in esophageal and gastric cardiac carcinoma resection
Jianqing LIN ; Zhijun HUAN ; Haihong SHI ; Deqiang FU ; Qixiang GUO
Clinical Medicine of China 2011;27(1):95-98
Objective To analyse the effects of anastomat to the resection surgery in 1800 esophageal and gastric cardiac carcinoma patients. Methods The Esophagus-gaster and Esophagus-intestine were stapled by anastomat in the cervical region in 182 cases、 intrathoracically in 1296 cases and intraperitoneal in 322cases. The occurrence of complications caused by anastomat, including anastomotic fistula,anastomotic stricture,anastomotic bleeding and mechanical failure,were observed. Results Anastomotic fistula occurred in 15 cases ( 15/1800,0.83% ,ten cases took Shanghai-made GF-I anastomat ,five cases took YH-W single disposable single anastomat ), among which 6 cases had the cervical anastomosis; Anastomotic stricture occurred in 41 cases ( 41 /1800,3.11%, fifteen cases took Shanghai-made GF-I anastomat, twenty-six took YH-W single disposable single anastomat) ,but all of them recovered after dilatation; Anastomotic bleeding occurred in 21 cases (21/18001.16%, thirteen cases took Shanghai-made GF-I anastomat, eight took YH-W single disposable single anastomat) ;Anastomat mechanical failure in operation occurred in 14 cases( 14/1800,0. 78% ,ten cases took Shanghai-made GF-I anastomat, four took YH-W single disposable single anastomat). Conclusion Anastomat is an effective method in reducing the postoperational complications of esophageal and gastric cardiac carcinoma resection. Disposable single anastomat has higher clinical value.
3.Analysis of Feasibility of Opportunistic Screening for Colorectal Cancer in High Risk Population
Zhijun LU ; Weiqiang WANG ; Huan CAI ; Binbin BAI ; Zhandong FAN
Chinese Journal of Gastroenterology 2017;22(7):423-425
Background:Screening of colorectal cancer (CRC) and colorectal adenoma (CRA), the precursor of CRC, is crucial for CRC prevention.It is believed that opportunistic screening of CRC in high risk population would narrow down the screening scope and save the health resources, and is suitable for the present status in China.Aims:To analyze the performance of high risk factors in predicting CRC/CRA, for exploring the feasibility of opportunistic screening for CRC in high risk population.Methods:A total of 1 862 outpatients and health examination subjects undergoing colonoscopy from Feb.2015 to Aug.2016 at the PLA 281 Hospital were recruited and asked to complete a questionnaire of high risk factors for CRC and CRA before colonoscopy.The questionnaire was designed based on the updated consensus on the screening and management of early colorectal cancer and precancerous lesion in China.Using the results of colonoscopy as gold standard, the predictive performance of high risk factors for CRC/CRA was analyzed.Results:Four hundred and sixty-eight (25.1%) individuals with high risk factors for CRC/CRA were screened out by the questionnaire.The detection rate of CRC in individuals with high risk factors was significantly higher than those without (17.5% vs.0.9%, P=0.000).The sensitivity, specificity, positive and negative predictive values of high risk factors in predicting CRC were 87.2%, 78.2%, 17.5% and 99.1%, respectively, and the missed diagnosis rate was 12.8%.For CRC/CRA, the corresponding figures were 83.2%, 87.0%, 57.3%, 96.1% and 16.8%, respectively.The risk ratios (RR) of high risk factors for CRC and CRC/CRA were 20.35 and 14.78, respectively.Conclusions:Opportunistic screening of CRC in high risk population is feasible and applicable in China under present condition.
4.The Technique of SCTA Image in Aortic Dissection
Xuepeng GONG ; Yi HUAN ; Zhijun YOU ; Yani BAI ; Wei SHI
Journal of Practical Radiology 2001;0(07):-
Objective To study the scan parameter of spiral CT angiography in aortic dissection.Methods 34 cases with aortic dissection successively underwent SCTA were studied retrospectively.The CT scan parameters,methods of posteriorimage treating were reviewed and analysed one by one.Results In 34 cases,32 cases were diagnosed as aortic dissection and classified correctly,in accordance with the result of operation and DSA,the quality of image was satisfied and the rate of success at least above 88.9%.The use of main scan parameters:(1)the ascend aortic dissection:slice thickness 4 mm,reconstruction interval 2 mm,pitch 1.25;tube current 175 mA;(2)involed in ascend,arch,descend and throacic aorta dissection:slice thickness 5 mm,reconstruction interval 2~3 mm,pitch 1.5;tube current 150 mA;(3)involved in abdominal aortic dissection:slice thickness 6~8 mm,reconstruction interval 2~3 mm,pitch 1.5 or 1.75;tube current 125 mA.The tube voltage all were 120 kV,the dosage of contrast media was 90~100 ml;the delayed scan time was choiced 20 second in throacic aortic and 25 second in abdominal aortic.The posterior image methods main used MPR,SSD,MIP and VR. Conclusion To set a sensible scaning plan,choose and match scan parameters properly according to the scaning length,can avoid the shortage of restrain SCTA scaning length and get satisfied image.
5.Effect of constant magnetic field on the osteopontin gene expression in rat aorta smooth muscle cells
Tao HU ; Lian ZHOU ; Wanqi JIE ; Haichang WANG ; Zhentao YU ; Zhengxian LI ; Huan LI ; Zhijun YANG
Chinese Journal of Tissue Engineering Research 2007;11(48):9805-9808
BACKGROUND:Constant magnetic field of proper intensity can inhibit the proliferation of vascular smooth muscle cells,and it can be used to inhibit the restenosis following percutaneous coronary intervention.OBJECTIVE: To observe the effect of constant magnetic field of different intensities on the expression of osteopontin gene in rat aorta smooth muscle cells, so as to investigate whether magnetic field can be used to prevent and treat restenosis following percutaneous coronary intervention.DESIGN: A randomly grouping and controlled observation.SETTING: Department of Cardiology, Xijing Hospital of the Fourth Military Medical University of Chinese PLA.MATERIALS: The experiments were carried out in the laboratory of Department of Cardiology (Military Institute of Cardiovascular Disease), Xijing Hospital of the Fourth Military Medical University of Chinese PLA from February to December in 2006. Male pure SD rats of 200-250 g were used.METHODS : Rat aorta smooth muscle cells were cultured in vitro in DMEM medium containing fetal bovine serum (0.1 in volume serum), and then the cells were randomly divided into control group, constant magnetic field of 1, 5, 10 and 50 Gs groups, those in the control group were not treated with magnetic field, and those in the other groups were treated with magnetic field and cultured for another 48 hours. Reverse transcription-polymerase chain reaction and Western blotting were combined with absorbance (A) scanning analysis to observe the effect of constant magnetic field on the expressions of osteopontin and its mRNA in smooth muscle cells.MAIN OUTCOME MEASURES: Expressions of osteopontin and its mRNA in smooth muscle cells.RESULTS: The expressions of osteopontin and osteopontin genes in the constant magnetic field groups were significantly decreased as compared with that in the control group (P < 0.05), there were also significant differences among the constant magnetic field groups of different intensities (P < 0.05). It was indicated that the stimulation of constant magnetic field was in an intensity-dependent manner, and the expressions of osteopontin and osteopontin mRNA were enhanced as the intensity of magnetic field was increased.CONCLUSION: Constant magnetic field of proper intensity can inhibit the osteopontin expression in vascular smooth muscle cells on the gene level, and magnetic field may play a role in preventing and treating the restenosis following percutaneous coronary intervention.