1.Development of measurement methodology with reference air kerma of 192Ir source afterloding in bracytherapy
Suming LUO ; Zhijian HE ; Lei GAO
Chinese Journal of Radiological Medicine and Protection 2008;28(4):398-400
Objective To develop measurement of reference air kerma for192Ir sources with NE 2570 electrometer,2571 ion-chamber and machining measured holder.Methods The measuring holder was placed at the distance of 1 m from the walls,the floor and ceiling,the ion-chambet was insert into the oolymethyl methacrylate(PMMA)jig of the measuring holder,lhe optimum distance is 16 cm from the source centre to ionchamber centre.The source was transmitted by the afterloding system to the plastic pipe to measure reference air kerma of the source.According to calibration factors from60Coγrays and 250 kV X rays with air exposure to calculated the air kerma calibration factor,the air kerma calibration factor of 192Ir soHree was calculated bv60Co γ rays and the effective energy of the 250 kV X ray beam.The scatter correction factor was giverl by the shadow shield experiment for the wails,the floor,the air and the measuring holder,the correction factors were given for the attenuation of primary photons in air and the electrons entering the air cavity are mainly generated in the innerwall of the chamber by 1079 report in IAEA.Results Two measuring methods were used for192Ir source undersame environment condition,the ion-chatuber and well-type chamber values are 1.584×1011Bq and 1.561×1011Bq respectively,and the relative deviation from them is within 1.4%,Conclusions The air kerma measurement of 192Ir source the ion-chamber with is not depended on the source geometry(point seurce,line source etc),the size.and the material of shell,the shape,the quality of materials and the size of the chamber.The uncertainty error of the air kerma is lessin comparison to the air exposure.
2.Development of measurement method using TLD for workers occupation personally exposed to 125Ⅰ seed source in the implant
Suming LUO ; Zhijian HE ; Jilong YUAN ; Baorong YUE ; Kedao WEI
Chinese Journal of Radiological Medicine and Protection 2011;31(4):398-403
Objective To explore the method for measuring and calculating both absorbed dose and effective dose received in organ and tissues of occupational workers by using TLDs for the implantation of 125Ⅰ seed sources.Methods The experiments with 60Co γ-rays were carried out for the stability.A group of TLD chips was exposed to 125Ⅰ seed sources to establish standard dose curve for air kerma.During the 125Ⅰ seed implantation, the TLD chips were pasted to 13 locations like thyroid inside and outside the lead aprons worn by occupational workers to measure average absorbed dose and calculate the absorbed doses and effectives to organs and tissues.Results For 3 cases of prostate cancers with implantation of 125Ⅰ seeds, the worker's organs and tissues received the absorbed dose 0.02 -3.80 μ Gy and effective dose 0.06- 1.81 μSv outside lead aprons and the highest absorbed dose 2.35 μ Gy and effective 0.02 μSv inside lead aprons, respectively, with more than 65.9% of rays shielded.For 3 cases of brain cancers with implantation of 125Ⅰ seeds, the workers received the absorbed dose 0.23 - 11.31 μGy and effective dose 0.88 - 4.07 μSv outside lead aprons and the highest absorbed dose 2.22 μ Gy and effective dose 0.09 μSv inside lead aprons, respectively, with more than 54.5% of rays shielded.For 3 cases of lung cancers with implantation of 125Ⅰ seeds, the workers received the absorbed dose 0.03 - 14.78 μGy and effective dose 0.35 -7.59 μSv outside lead aprons and the highest absorbed dose 4.09 μGy and effective 0.22 μSv inside lead aprons, respectively, with more than 58.4% of rays shielded.For 2 cases of mediastinum cancers with implantation of 125Ⅰseeds, the workers received the absorbed dose 0.06 - 74.91 μGy and effective dose 0.83 - 17.96 μSv outside lead aprons and the highest absorbed dose 10.29 μGy and effective 0.5 μSv inside lead aprons, respectively, with more than 85% of rays shielded.For one case of ovary cancer with implantation of 125Ⅰ seeds, the worker received the absorbed dose 0.09 - 14.29 μGy and effective dose 2.40 - 4.50 μSv outside lead aprons and the highest absorbed dose 7.77 μGy and effective 0.12 μSv inside lead aprons, respectively, with more than 34% of rays shielded.For one case of eye cancer with implantation of 125Ⅰ seeds, the workers received the absorbed dose 2.2 -39.84 μGy and effective dose 4.48 - 10.06 μSv outside aprons and the highest absorbed dose 5.19 μGy and effective 0.16 μSv inside aprons, respectively, with more than 54.6 % of rays shielded.Conclusions The method of using TLDs to measure the doses to the occupational workers in the course of the implantation of 125Ⅰ seed sources is simple and easy to operate.It would be an effective approach to protecting medical workers in the case of brachytherapy.
3.The levels of Livin and Caspase-3 in rats renal tissue induced by paraquat and the therapeutical effects of ulinastatin
Zhijian ZANG ; Congyang ZHOU ; Yajuan LUO ; Libo PENG
Chinese Journal of Emergency Medicine 2011;20(7):717-721
Objective To observe the levels of Livin and Caspase-3 in renal tissue of rats following acute paraquat (PQ) poisoning and the intervention effects of ulinastatin (UTI) . Methods Fifty-four Sprague-Dawley (SD) rats were randomly divided into three experimental groups: control group (group A),PQ poisoning group (group B) and UTI group (group C) (n = 18 in each group) . Rats in group B and group C were administered intragastrically with 80 mg/kg PQ, and rats in group C were treated with 100,000U/kg ulinastatin injected intra-psritoneally once a day; and rats in group A were administered intragastrically with the same volume of saline instead of PQ. At 24, 48, 72 hours after poisoning, the levels of Livin in renal tissue were detected by Westen blotting and the levels of Caspase-3 were detected by immunohistochemistry 24, 48, and 72 hours after poisoning, and the histopathological changes of renal tissue were observed at the same time. Results In the group A, the structure of renal tissue was distinct. In the group B, the distinctness of the structure of renal tissue declined significantly, and swelling, edema and vacuolar degeneration were observed 24 h after poisoning, and pathological changes became more and more obvious keeping pace with time elapsing, and sometimes karyopyknosis appeared and celluar structures disappeared with involvement of renal glomerulus and medulla. These pathological changes were significantly lessened in rats of group C. In the group A, there was little Caspase-3 in renal tissue of rats. Twenty-four hours after poisoning, the caspase-3 in renal tissue of rats of group B was found on the membrane and in the kytoplasm of renal tubular epithelial cells of cortical part. Compared with group B, the level of Caspase-3 in renal tissue of rats of group C decreased significantly to lower level (P <0. 01 ) . Compared with group A,the levels of Livin in renal tissue in rats of group B and group C increased significantly at all different intervals (P <0. 01 ), and as group B was compared with group C, the difference was statistically significant (P <0. 01 ) . Conclusions The main pathologyical changes of renal injury induced by PQ are epithelial swelling, vacuole degenerateion and necrosis. Caspase-3 is involved in the process of renal injury. UTI has a protective effect on the renal tissue of rats following paraquat poisoning through up-regulating the level of Livin and down-regulating the level of Caspase-3, however, the regulation mechanism as well as the pathway is still needed to further study.
4.Development on Monte Carlo methodology with scatter correction factor of afterloading 192Ir source
Jilong YUAN ; Suming LUO ; Zhijian HE ; Lei GAO
Chinese Journal of Radiological Medicine and Protection 2011;31(1):79-82
Objective To facilitate activity measurement by using the thimble ionization chamber in hospitals,to obtain air kerma scatter correction factor of medical afterloading of 192Ir source by developing an available and convenient calculation method.Methods According to International Atomic Energy Agency (IAEA) 1079 Report to calculate the scatter correction factor of 192 Ir source,to measure air kenna of 192Ir source with and without lead shield using thimble ionization chamber.Simulation measurement conditions were used to calculate scatter correction factor of 192Ir source and comparison was made between experimental results and literature records.At the same time,the different ionization chamber models were simulated at different room sizes to obtain scattering correction factor of 192 Ir source.ResultsComparison was made between the simulation scatter correction factors of 192Ir source and experiment by the shadow shield,and the relative deviation was 0.8%.The deviation of the 192 Ir activity calculated according to the simulated scatter correction factor and measured by well type ionization chamber was 2.4%.By comparison between the calculated results by using two kinds of spherical ionization chamber and those ones deduced by IAEA 1079 Report,the relative deviations ranged within 0.3%-0.4%.Five different types of thimble ionization chamber and different room sizes were simulated and calculated by MC simulation,with the relative deviation within 3%.Conclusions Monte Carlo simulation method for calculating afterloading 192 Ir source's scatter correction factor is feasible,and this method is convenient for use in the thimble chamber for brachytherapy QA work in the hospital.
5.Evaluation and test of 192Ir air kerma strength for afterloading systems
Suming LUO ; Zhijian HE ; Lei GAO ; Baorong YUE
Chinese Journal of Radiological Medicine and Protection 2011;31(1):76-78
Objective To study the method of measuring air kerma strength of afterloading units with 192Ir source by using well type ionization chamber.MethodsThe air kerma strength of 30 afterloading units with 192Ir source was measured using 2000A electrometer and 1000 plus well type ionization chamber,and apparent activity of the source was calculated with the air kerma strength and apparent activity conversion factor.The measured activity of the source was compared with the original value of the source provided by the manufacturer,and the relevant deviation should be within ± 5%.Results Theair kerma strength of afterloding units with 192Ir sources was tested.The relevant deviation of the measured activity and the original value was within -0.1%-4.4%.Conclusions The measurement method with a well type ionization chamber is convenient and highly accurate which can be used for the test of quality control in hospitals.
6.THREE-DIMENSIONAL COMPUTERIZED RECONSTRUCTION OF HEART AND CORONARY ARTERY ON INTERNET
Wensheng LI ; Zhijian SONG ; Shumin ZHAO ; Baoguo LUO ; Huanchen ZUO
Acta Anatomica Sinica 1954;0(02):-
Objective To reconstruct three-dimensional (3D) image of heart and coronary artery on internet and explore the reliability. Methods After the contrast medium was injected into coronary artery of 2 heart specimens, hearts were scanned by UFCT with enhancement volume. One patient's UFCT images of coronary artery angiography were also chosen.Then the primitive images were transposed format, removed noise, specified interesting areas. 3D software on server was applied to reconstruct heart and coronary artery. Results The reconstructed 3D images of the heart and coronary artery were realistically displayed, freely rotated and transected.Main parts and branches of coronary artery were similar to those in the images of the UFCT. Conclusion Heart and coronary artery can be reconstructed on internet,which offers a new approach for reconstructing organs and tissues of human being.;
7.Motion signal extraction method based on sEMG energy Gauss distribution characteristics.
Ruihui LI ; Zhijian FAN ; Cuilian ZHAO ; Linhui LUO ; Kai WANG
Chinese Journal of Medical Instrumentation 2014;38(3):177-180
Motion segment and extraction from continuous signals is the premise of surface electromyography (sEMG) analysis. For the problem that sEMG energy threshold required repeated manual testing to set, this the paper established a this mathematical model of continuous actions based on Gaussian sEMG energy curve, in which the energy threshold was set according to the distribution of Gaussian signal section, and differentiated the action signals from no-action signals combined with energy comparison method. The experiment results showed the method can achieve continuous repetitive action segmentation, and compared with manual segmentation of the same signal, has a higher degree of coincidence.
Algorithms
;
Electromyography
;
Humans
;
Motion
;
Pattern Recognition, Automated
;
Signal Processing, Computer-Assisted
8.Optimal timing for laparoscopic cholecystectomy after endoscopic sphincterotomy
Xiaozai LUO ; Yongping FANG ; Kunping LI ; Zhijian LIANG
Chinese Journal of Hepatobiliary Surgery 2016;22(11):757-760
Objective To determine whether it is better to carry out laparoscopic cholecystectomy (LC) immediately or 3 days after endoscopic sphincterotomy (EST) in patients with common bile duct stones and gallbladder stones.Methods A retrospective study was conducted on 160 patients who had common bile duct stones and gallbladder stones treated from July 2013 to July 2015 in the First People's Hospital of Huizhou.These patients were divided into a control group and an observation group,with 80 patients in each group.The control group underwent LC immediately after EST,while the observation group underwent LC 3 days after EST.The levels of blood amylase before LC,operation time,intraoperative bleeding volume,postoperative time to first flatus,postoperative complication after EST,postoperative hospitalization stay,total hospitalization stay and total hospital costs and incidences of postoperative complication after LC were compared between the two groups.Results The time periods of total hospitalization stay in the observation group and the control group were (18.2 ±3.5) d and (12.3 ±3.0) d,respectively (P<0.05).The total costs in the two groups were (32 164 ±9 125) RMB and (22 375 ±7 860) RMB,respectively (P < 0.05).The overall incidences of postoperative complication [patients (%)] were 5 (6.3) and 9 (11.3),respectively (P < 0.05).The differences on preoperative serum amylase levels,LC operative time,blood loss,postoperative time to first flatus and postoperative hospitalization stay were not significantly different (P > 0.05).Conclusion LC carried out on day 3 after EST to treat common bile duct stones and gallbladder stones was clinically more efficacious.
9.Verification of dosimetric methodology for auditing radiotherapy quality under non-reference condition in Hubei province
Xinxing MA ; Suming LUO ; Zhijian HE ; Wenshan ZHOU
Chinese Journal of Radiological Medicine and Protection 2014;34(6):461-465
Objective To verify the reliability of TLD-based quality audit for radiotherapy dosimetry of medical electron accelerator in non-reference condition by monitoring the dose variations from electron beams with different field sizes and 45° wedge and the dose variations from photon beams with different field sizes and source-skin distance.Methods Both TLDs and finger ionization chambers were placed at a depth of 10 cm in water to measure the absorbed dose from photon beams,and also placed at the depth of maximum dose from electron beams under non-reference condition.TLDs were then mailed to National Institute for Radiological Protection,China CDC for further measurement.Results Among the 70 measuring points for photon beams,58 points showed the results with a relative error less than ± 7.0% (IAEA's acceptable deviation:± 7.0%) between TLDs and finger ionization chambers measurements,and the percentage of qualified point numbers was 82.8%.After corrected by P,value,62 points were qualified and the percentage was up to 88.6%.All of the measuring points for electron beams,with the total number of 24,presented a relative error within ± 5.0% (IAEA's acceptable deviation:± 5.0%) between TLDs and finger ioization cylindrical chambers measurements.Conclusions TLD-based quality audit is convenient for determining radiotherapy dosimetric parameters of electron beams in non-reference condition and can improve the accuracy of the measuring parameters in connection with finger chambers.For electron beams of 5 MeV < E0 < 10 MeV,the absorbed dose parameters measured by finger ionization chambers,combined with TLD audit,can help obtain the precise and reliable results.
10.Development of methodology for auditing dosimetric parameters for photon and electron beams under non-reference conditions
Suming LUO ; Zhijian HE ; Kaibao LI ; Xian XUE
Chinese Journal of Radiological Medicine and Protection 2014;34(6):441-445
Objective To develop a methodology for auditing dosimetric parameters using TLD for photon and electron beams in non-reference conditions.Methods The correction experiments have been developed for non-linear dose response,PAAM holder,energy,fading and dispersion using TLD for 60Co γ-ray,high energy X-ray and electron beams.The measuring method was set up for absorbed dose estimation by TLDs in water.3 photon beams and 2 electron beams were selected for research purposes,and 5 photon beams and 4 electron beams for reliability research.Results The research results were evaluated for60Co source,6,10,15 and 18 MV photon beams in non-reference conditions at off-axis,with the relative deviation within-0.1%-7.2% at-off axis (IAEA's acceptable deviation:± 7.0%).The verification results were evaluated for 5 photon beams in non-reference conditions at on-axis,with the relative deviation are within 0.1%-7.0%.The verification results were evaluated for 4 electron beams in non-reference conditions,with the relative deviation within 0-4.7% (IAEA's acceptable deviation:±5.0%).Conclusions It is convenient and accurate to use TLD method for quality audits for clinic dosimetry parameters in radiotherapy.Two kinds of IAEA TLD holders are feasible for use in TLD audits.Absorbed doses for high energy electron beam were corrected using plane parallel chambers and verified using TLD,with good results obtained.