1.Clinical research of Xingnaojing injection combined with naloxone in the treatment of hypoxic ischemic encephalopathy
Buqing MA ; Jinhua WANG ; Long CHI ; Heng LIANG ; Zhihan PIAO ; Wuqing ZOU
Chinese Journal of Primary Medicine and Pharmacy 2017;24(1):103-106
Objective To observe the clinical effect of Xingnaojing injection combined with naloxone in the treatment of hypoxic ischemic encephalopathy.Methods 62 patients with hypoxia ischemia encephalopathy were randomly assigned into the control group(31 cases)and the treatment group(31 cases).The control group used naloxone treatment on the basis of the conventional treatment.The treatment group received Xingnaojing injection combined with naloxone treatment on the basis of routine treatment.The changes in different time of Glasgow Coma Scale(GCS) scores of the two groups after treatment were compared.Results After treatment for 1 ,5,1 0,1 5d,the GCS scores in the control group were (5.27 ±0.87)points,(9.03 ±0.72)points,(1 0.03 ±0.72)points,(1 3.03 ±0.72)points respectively,which in the treatment group were (5.1 4 ±1 .03)points,(9.24 ±1 .06)points,(1 3.31 ±2.83)points, (15.31 ±0.93)points.The differences of GCS scores after treatment for 15,10d between the two groups were statistically significant(t =1 5.1 1 3,1 0.501 ,P =0.00,0.00).In the control group,the total effective rate was 50.0%,which of the treatment group was 82.7%,the total effective rate between the two groups had statistically significant difference (χ2 =6.437,P <0.05).Conclusion On the basis of routine treatment,Xingnaojing injection combined with naloxone in the treatment of hypoxic ischemic encephalopathy has better effect than the single use of naloxone treatment.
2.Clinical observation of recombinant human brain natriurefic peptide in acute anterior myocardial infarction complicated with heart failure
Zhi JIA ; Yu SONG ; Mu GUO ; Yunqiang ZHANG ; Haiqing LIANG ; Zhihan PIAO ; Shuguang TIAN
Clinical Medicine of China 2012;28(4):373-376
Objective To evaluate the efficacy of intravenous recombinant human brain natriuretic peptide in acute anterior myocardial infarction complicated with heart failure.Methods Two hundred patients suffered from acute anterior myocardial infarction complicated with heart failure were randomly divided into two groups:rhBNP group ( n =100) and control group ( n =100 ).All patients were given conventional treatment,patients in rhBNP group were given rhBNP on the basis of conventional therapy.The clinical effectiveness including the improvement of cardiac function,cardiac ultrasound data,the incidence of hospital adverse cardiac events,and six month follow-up were compared between the two groups.Results The degree of decompensation and Killip class in rhBNP group were better than those of control group after treatment ( improved dyspnea:significantly improved:36 vs 27 ; improved:49 vs 46; no improvement:11 vs 20 ; deterioration:4 vs 7 ; Ridit value:0.4618 vs 0.5382,P =0.043) ( Killip class:significantly improved:26 vs 20; improved:56 vs 45; no improvement:14 vs 25 ; deterioration:4 vs 10; Ridit value:0.4553 vs 0.5447,P =0.017 ).After treatment for one week,The LVEF improvement in rhBNP group was more remarkable than that of control group ( [ 53.0 ± 5.2 ] %vs.[ 50.0 ±:6.2 ] %,P =0.014).The occurrence rate of angina ( 13.0% vs.27.0%,P =0.013 ),heart failure ( 18.0% vs.32.0%,P =0.022) and major adverse cardiac events(MACE) ( 17.0% vs.30.0%,P =0.030) inrhBNP group was lower than that in control group.During 6 months follow-up period,event-free survival in rhBNP group was higher than that in control group ( 69.0% vs.55.0%,P =0.041 ).Conclusion Transvenous injection of rhBNP combined with other routine treatment can improve cardiac function in patients with myocardial infarction in acute anterior myocardial infarction.It can also decrease adverse cardiac events during hospitalization and increase event-free survival in 6 months follow-up period.
3.Application of 3D-printing patient-specific instruments combined with customized locking plate in opening wedge high tibial osteotomy
Chi MA ; Ning WANG ; Yong CHEN ; Zhihan WEI ; Fengji LIU ; Chengzhe PIAO
Chinese Journal of Tissue Engineering Research 2025;29(9):1863-1869
BACKGROUND:The use of 3D-printed patient-specific instruments in opening wedge high tibial osteotomy has advantages such as shorter operative time,fewer fluoroscopic exposures,and higher correction accuracy.However,previous studies have reported issues such as significant damage to surrounding soft tissues and improper fixation of the plates. OBJECTIVE:To investigate the clinical efficacy of using 3D-printed patient-specific instruments combined with customized locking plate in opening wedge high tibial osteotomy for the treatment of knee osteoarthritis. METHODS:A total of 20 patients diagnosed with knee osteoarthritis were divided into the 3D group(n=10)and the conventional group(n=10)according to surgical methods.The 3D group underwent opening wedge high tibial osteotomy using 3D-printed patient-specific instruments combined with customized locking plate,while the conventional group underwent opening wedge high tibial osteotomy using conventional methods.The operative time,fluoroscopic exposures,incision length,pre-and postoperative hip-knee-ankle angle,medial proximal tibial angle,posterior tibial slope,the difference between the planned and actual correction angle,preoperative and 1,3,6 months postoperative knee range of motion and Lysholm score,and incidence of complications were analyzed and compared between the two groups. RESULTS AND CONCLUSION:(1)The operative time and fluoroscopic exposures were significantly shorter in the 3D group compared to the conventional group,with a statistically significant difference(P<0.001).(2)Both groups showed a significant improvement in postoperative hip-knee-ankle angle and medial proximal tibial angle compared to preoperative values,with a statistically significant difference(P<0.001),while there was no significant change in posterior tibial slope.In the 3D group,the postoperative hip-knee-ankle angle,medial proximal tibial angle,and posterior tibial slope differed from their respective preoperative planned values by(-0.22±0.72)°,(-0.20±0.73)°,and(0.23±0.37)°,but the differences were not statistically significant.The difference between the planned and actual correction angle of 3D group was significantly smaller than that of conventional group(P<0.05).(3)Both groups showed a gradual increase in knee range of motion and Lysholm scores after surgery(P<0.001).Compared to the conventional group,the 3D group had superior knee range of motion at 1 and 3 months postoperatively,as well as a higher Lysholm score at 1 month postoperatively,with statistically significant differences(P<0.05).There were no statistically significant differences in Lysholm score at 3 months and knee range of motion and Lysholm score at 6 months between the two groups(P>0.05).(4)Complications occurred in neither groups.(5)The above results indicate that both 3D-printed patient-specific instruments combined with customized locking plate and conventional methods have good clinical efficacy.However,the former has a shorter operative time,fewer fluoroscopic exposures,and faster postoperative recovery of knee joint function.Additionally,3D-printed patient-specific instruments can achieve preoperative planning accurately.