1.The role of MR-diffusion tensor imaging in the assessment of Alzheimer′s disease
Ye SUN ; Xiangke DU ; Zhiguo SUN ; Zhenxin ZHANG
Chinese Journal of Radiology 2001;0(01):-
Objective To evaluate the possible white matter damage and to define the location of the damage in Alzheimer′s disease (AD) with diffusion tensor imaging (DTI). Methods Twenty-four AD patients and twenty-one age-matched healthy volunteers received conventional and DTI scanning.The ADC and FA of white matter in temporal, parietal, frontal lobe and cingulum were measured respectively and the data underwent postprocessing.Results FA value of the whiter matter in frontal, parietal, temporal and cingulum in AD patients was 0.37?0.06, 0.32?0.05, 0.26?0.03, and 0.47?0.09, respectively, and ADC value was 9.50 e-10?2.02 e-10, 10.55 e-10?1.43 e-10, 11.45 e-10?0.76 e-10, and 10.10 e-10?2.18 e-10, respectively;FA value of the same corresponding regions in control was 0.44?0.06, 0.38?0.05, 0.32?0.05, and 0.56?0.06, respectively, and ADC value was 8.75 e-10? 1.63 e-10, 9.83 e-10?0.99 e-10, 11.13 e-10?0.78 e-10, and 8.28 e-10?1.65 e-10, respectively.FA value of the whiter matter in frontal, parietal, temporal, lobe and cingulum decreased (P≤0.006) and ADC value increased in cingulum white matter (P≤0.006) in AD patients.Conclusion DTI could reveal the damage in white matter of frontal, temporal, parietal lobe and cingulum.It suggested that not only the gray matter is injuried, but also the white matter is abnormal in AD patients.
2.Treatment of old fracture-dislocation of proximal interphalangeal joint using a pins-rubber distraction external fixator
Huazhu WANG ; Zhiguo DU ; Guangxian CHEN ; Yanhong GAO ; Tong LI ; Xing WU ; Jianyong ZHAO
Chinese Journal of Orthopaedics 2012;32(7):669-674
Objective To discuss the clinical outcomes of old fracture-dislocation of proximal interphalangeal joint treated with a self-made distraction external fixator which consists of 3 pins and rubbers.Methods From March 2005 to August 2011,8 cases of old fracture-dislocation of proximal interphalangeal joint treated with a pins-rubber distraction external fixator were retrospectively reviewed.There were 6 males and 2 females,aged from 17 to 58 years,averaged 23.2 years.The middle finger was involved in 5 cases and ring finger was involved in 3 cases.The right hand was affected in six patients,and the left hand was affectd in two patients.The mechanism of injury was sports injury in 6 cases,traffic injuries in 1,and sprain in 1.All of the cases were closed injury.The mean time from injury to surgery was 58 d (range,45-90 d).According to Schenck classification of the proximal interphalangeal joint fracture-dislocation,there were 4 cases of type Ⅰ,3 of type Ⅱ,I of type Ⅲ.Based on the Michigan Hand Outcomes Questionnaire (MHQ) for subjective hand function score,the average preoperative score was 56; the range of motion of proximal interphalangeal joint was 0°.Grip strength was 60%-80% of the contralateral hand.Results The follow-up lasted 6-51 months,with a mean period of 20.5 months.Solid bone healing was eventually achieved in all patients.The average healing period was 3 months (range,2-5 months).The mean normalized MHQ score was 88 (range,84-92).Grip strength was 85%-100% of the contralateral hand.Extension of proximal interphalangeal joint was -10°-0° (average,-5°).Flexion angle was 75°-100° (average,89.4°).Postoperative complications included slight joint space narrowing (2 cases),joint incongruity (< 1 mm) (2 cases) and fusiform arthrocele (2 cases).No infection,pin loosening,and pin breakage was encounted.Conclusion A pins-rubber distraction external fixator is a minimally invasive,reliable and effective treatment for old fracture-dislocation of proximal interphalangeal joint.
3.On-line Quantitative Monitoring and Control of Tobacco Flavors by Near Infrared Spectroscopy Combined with Advanced Calibration Transfer Method
Xinzhen SHI ; Zhiguo WANG ; Wen DU ; Hao YI ; Juan ZHANG ; Zengping CHEN ; Ruqin YU
Chinese Journal of Analytical Chemistry 2014;(11):1673-1678
Whennearinfraredspectroscopyisappliedtoon-linemonitoringandcontroloftobaccoflavors,the variation in temperature can severely deteriorate the predictive performance of near infrared spectroscopic calibration models and results in a significant increases of the root mean square error value for the main constituents in syrup samples from 2. 4% to 29. 0%. In this paper, near infrared spectroscopy has been incorporated with an advanced calibration transfer method-loading space standardization to effectively eliminate the deteriorate effects of temperature variation on quantitative results and finally realize the fast and accurate on-line quantitative monitoring and control of tobacco flavors. The root mean square error value for the main constituents in syrup samples is successfully retained at a satisfying low level of 3 . 8%. The results of this paper will provide technical support for the preparation, preservation and use of tobacco flavors, and realize on-line process quality control of cigarettes.
4.Catheter directed thrombolysis treatment of acute lower extremity deep venous thrombosis of the clinical problem analysis
Zhiguo WEN ; Yanzhou LI ; Xiaoxu ZHAO ; Ling HU ; Liping DU ; Jingjing QU
Chinese Journal of Postgraduates of Medicine 2014;37(29):19-21
Objective To discuss and analyze the issue in the catheter directed thrombolysis(CDT) treatment of acute lower extremity deep venous thrombosis.Methods The clinical data of 182 cases of acute lower extremity deep venous thrombosis from January 2011 to January 2013 which were treated by CDT were retrospectively analyzed,and the issues in these treatment were discussed and analyzed.Results The effect were classified into three degrees.Thrombosis clearance exceed 95 percent belonged to the first degree,among 50 percent and 95 percent belonged to the second degree,and below 50 percent belonged to the third degree.In this study,the respective number of each degree were 93/68/21.Sixty-one cases combined iliac venous compression syndrome were treated by stent.Twenty-two cases were treated with inferior vena cava filter.All the patients were followed up 10 months,148 cases of them maintained patency.Conclusions The effect of CDT treatment to acute lower extremity deep venous thrombosis is remarkable,meanwhile the patency is improved and the deep vein thrombosis were decreased through this method.But the issues of access,filter and iliac venous compression syndrome should also be considered.
5.Co-culture of C3A cells and pancreatic endothelial cells and its effects on C3A cell functional changes
Zhiguo LI ; Xueyi CUI ; Yan WANG ; Jiang DU ; Yuzhan KANG ; Yi GAO
Chinese Journal of Hepatobiliary Surgery 2010;16(6):447-450
Objective To investigate the functional changes of C3A cells co-cultured with pancreatic endothelial cells. Methods C3A cells and pancreatic endothelial cells lwere cultivated directly and indirectly for 7 days by the density ratio of 10: 1. Meanwhile, the blank control was established.The growth and morphological characteristics of experimental groups were observed. The out leakage level of AST, ALT and the synthesis level of albumin and the diazepam metabolism level were determined by automatic biochemistry analyzer, radioimmunoassay and enzyme linked immunosorbent assay. Results Direct co-cultivation of C3A cells and pancreatic endothelial cells could reduce the out leakage of ALT and AST in the 5th and 7th d. The capacity of albumin synthesis could reach 12. 977μg/ml on the 7th d and the that of diazepam metabolism could also be improved. Indirect co-cultivation of C3A cells and pancreatic endothelial cells could significantly raise the albumin synthesis to 7. 380 μg/ml and 10. 773 μg/ml on the 5th and 7th d, respectively. Conclusion Co-cultivation of C3A cells and pancreatic endothelial cells can significantly improve the basic biological function of C3A cells.
6.Association analysis of the rs10043986 polymorphism of cardiomyopathy-associated 5 gene with schizophrenia in Uygur Chinese population
Shuxian HAN ; Zhiguo AN ; Lili ZHANG ; Jiangtao WANG ; Xiao LUO ; Wen DU ; Qizhong YI
Chinese Journal of Behavioral Medicine and Brain Science 2015;24(1):27-30
Objective To evaluate the relationship between cardiomyopathy-associated 5 (CMYAS) gene rs10043986 polymorphism and schizophrenia in Uygur Chinese population.Methods The SNP rs10043986 in CMYA5 gene was genotyped in 325 patients with schizophrenia and 183 normal controls using TaqMan technology.The symptoms of schizophrenia were assessed by positive and negative syndrome scale (PANSS).The association of the loci with schizophrenia,age of onset,clinical symptom was analyzed.Results The allelic and genotypic distributions in rs10043986 between patients with schizophrenia (C,T allele:91.5%,8.5% ; C/C,C/T,T/T genotypes:83.4%,16.3%,0.3%) and normal controls (C,T allele:96.4%,3.6% ; C/C,C/T,T/T genotypes:92.9%,7.1%,0) had statistically significance after analysis (x2 =9.038,P=0.003 ; x2 =9.417,P=0.009).Via analysis of stratification by gender and age at onset.The results showed that both allele (x2=11.812,P=0.001) and genotype (x2=12.769,P=0.001) frequency in rs10043986 with patients were significantly different in females,but neither in males (all P>0.05).Allelic or genotypic distributions between adult cases and controls had statistically significance (x2=8.219,P=0.004; x2=8.379,P=0.015),but there were not significant differences between adolescent cases and controls (all P> 0.05).Furthermore,we also notice that the PANSS scores of patients between Genotype C/C and C/T had no statistically significance (allP>0.05).Conclusion The results reveal that T allele at CMYA5 rs10043986 may be confer risk for susceptibility of female and adult schizophrenia in Uygur Chinese population,and that rs 10043986 polymorphism may not significantly associate with symptoms severity of schizophrenia.
7.Analysis of error sources for routine chemistry external quality assessment program in China
Haijian ZHAO ; Chuanbao ZHANG ; Jie ZENG ; Jiangtao ZHANG ; Rong MA ; Zhongli DU ; Zhiguo WANG
Chinese Journal of Laboratory Medicine 2016;39(5):376-379
Objective To investigate and analyze the reasons of fa0ilure in external quality assessment(EQA) for routine chemistry and provide the basis for the corrective and preventive actions.Methods Based on the network system of NCCL EQA the reasons of failure in 2013 national routine chemistry external quality assessment program were investigated,among which the reasons were classified and analyzed with seven sources of problems which were clerical errors,methodological problems,equipment problems,technical problems,EQA materials problems,EQA Evaluation problems and unable to explain after investigation.Results The return rate of this root cause investigation for each analyte ranged from 33.3% to 80.0%.The major reason for unacceptable analyte included clerical errors (6.5%) (decimal point position error:70.1%;unit error:20.8%;instrument or method coding error:8.1%),methodological problems (45.1%)(calibration:54.2%;reagent:38.0%;EQA material:7.8%),equipment problems (28.5%) (no regular maintenance:98.0%;pipeline error:2.0%),technical problems (8.2%) (do not follow SOP:80.4%;EQA material redissolve error:10.6%;placing order error:9.0%) and unable to explain (11.7%) (system error:68.2%;random error:31.8%).There were no EQA materials problems or EQA Evaluation problems in this survey.Analysis systems' grouping statistics were implemented for seven analytes including sodium,chlorine,phosphorus,direct bilirubin,total iron binding capacity,copper,and zinc.Unsatisfied EQA proportions of mating system were lower than nonmatching ones for the majority of analytes.Conclutions Further work on EQA should be undertaken by clinical laboratories.Laboratories should use reagents with high quality as well as improve the operation technology and sense of responsibility.Only in this way,can the accuracy and reliability of testing results be guaranteed.
8.Investigation and analysis on the use of blood cell counting reference intervals in 2 869 hospitals in China
Jiali LIU ; Yuxuan DU ; Wei WANG ; Falin HE ; Shuai YUAN ; Zhixin ZHANG ; Zhiguo WANG
Chinese Journal of Laboratory Medicine 2021;44(5):408-412
Objective:To investigate the use of the reference intervals for blood cell counting and the reference of industry standard in China.Methods:Information from all laboratories was collected using online questionnaire in 18 reference intervals survey in blood cell counting in 2019. The information includes the source of the reference intervals, the verification of the reference intervals, and the upper and lower limits of the reference intervals, the method used, the instrument, the reagent and the calibrator. Microsoft Excel 2007 software was used to analyze the results of all laboratories. The median and 95% confidence interval were calculated. The distribution of the reference intervals for blood cell counting and their conformance to industry standards were analyzed.Results:2, 869 labs reported the data. The main sources were industry standards and National Guide to Clinical Laboratory Procedures. The proportion was 33.30%-35.02% and 28.55%-30.90% respectively. 49.44%-55.13% of laboratories validated the reference interval when citing industry standards. The reference interval grouping of most laboratories (89.37%-91.69%) cited in RBC, Hgb and Hct were consistent with the industry standards. We compared the upper and lower limits of the reference intervals with that given by the industry standards, when the lower limit of the reference intervals of mean corpuscular hemoglobin concentration, absolute neutrophils count, absolute basophils count, absolute monocyte count, and lymphocyte percentage were compared. The upper limit of reference intervals of neutrophils percentage as well as upper and lower limits of reference intervals of mean corpuscular volume, mean corpuscular hemoglobin, absolute eosinophil count, basophils percentage, and monocyte percentage were also compared. The median and mode were equal and consistent with industry standards. For other labs, the upper and lower limits of the reference intervals were not consistent with the reference intervals given by the industry standards.Conclusion:The use of reference intervals for blood cell counting was not the same, and the implementation of industry standards was not optimistic. A considerable number of laboratories had not verified the reference intervals, so it was necessary to promote the industry standards for reference intervals.
9.Effect of the interval of radical prostatectomy after prostate puncture on the perioperative period and prognosis of patients
Zhiguo JIANG ; Wei DU ; Jiacun CHEN ; Rumin WEN ; Junqi WANG
International Journal of Surgery 2020;47(5):321-325
Objective:To explore the effect of the interval of radical prostatectomy after prostate puncture on the perioperative period and prognosis of patients.Methods:Patient’s data from September 2016 to September 2018 whom performed laparoscopic radical prostatectomy at the Affiliated Hospital of Xuzhou Medical University were collected and retrospectively analyzed. All prostate biopsy confirmed prostate cancer and 66 patients underwent laparoscopic radical prostatectomy. The average age was (70.11 ± 5.01) years, ranged from 60 to 79 years. The patients were divided into two groups according to the interval time from prostate biopsy to laparoscopic radical prostatectomy: <7 d group ( n=32) and 6-8 weeks group ( n= 34). The operation time, intraoperative blood loss, postoperative hospital stays, positive rate of incisional margin, postoperative urinary incontinence rate and the rate of urinary incontinence 6 months after operation, rate of postoperative erectile dysfunction and bone metastasis were compared and analyzed between the two groups. When the data conformed to the normal distribution, the data were expressed in Mean±standard deviation ( Mean± SD), and the independent sample t-test was used to evaluate the statistical significance between groups. When the data did not conform to the normal distribution, the measurement data was expressed as Median (interquartile range) [ M( P25, P75)], and the Mann-Whitney U test was used for the comparison between groups. Count data comparison between groups using Chi-square test or Fisher exact probability method. Unconditional multivariate Logistic regression was used to analyze the relationship between outcome and exposure. Results:All the 66 patients successfully underwent surgery, the surgery success rate was 100%. The average operation time of <7 d group and group 6-8 weeks group was [185.00(174.50, 193.50)] min and [183.00(175.00, 187.50) min], respectively, the difference was not statistically significant ( P=0.685 8, U=512.0). The average intraoperative blood loss of group <7 d group and 6-8 weeks group was [185.50(177.75, 205.25)]ml, [189.00(180.75, 206.00)] ml, respectively, the difference was not statistically significant ( P=0.685 9, U=512.0). The average postoperative hospital stays of <7 d group and 6-8 weeks group was [14.00(11.75, 16.00)] d, [13.50(12.00, 15.00)] d, respectively, the difference was not statistically significant ( P=0.785 7, U=522.5). The positive rate of incisal margin of<7 d group and 6-8 weeks group was 18.75%, 14.71%, respectively, the difference was not statistically significant ( P=0.659 5, χ2=0.194). The postoperative urinary incontinence rate of <7 d group and 6-8 weeks group was 6.25% and 8.82%, respectively, the difference was not statistically significant ( P=1.000 0). The urinary control after follow-up for six months of <7 d group and 6-8 weeks group was 6.25% and 2.94%, respectively, the difference was not statistically significant ( P=0.607 7). The postoperative erectile dysfunction rate of<7 d group and group 6-8 weeks group was 9.38% and 8.82%, respectively, the difference was not statistically significant ( P=1.000 0). The postoperative bone metastasis rate of group<7 d and 6-8 weeks group was 6.25% and 5.88%, respectively, the difference was not statistically significant ( P=1.000 0). Conclusions:Performing laparoscopic radical prostatectomy within 7 days following prostate biopsy did not adversely affect the postoperative outcomes and prognosis, also not increased postoperative complications, can shorten the patient′s treatment cycle.
10.National survey of blood specimen acceptability for clinical chemistry tests in 2017
Yuanyuan YE ; Wei WANG ; Haijian ZHAO ; Falin HE ; Kun ZHONG ; Shuai YUAN ; Yuxuan DU ; Bingquan CHEN ; Zhiguo WANG
Chinese Journal of Clinical Laboratory Science 2018;36(6):467-471
Objective To investigate the status of blood specimen acceptability for clinical chemistry tests in routine medical laboratories of China. Methods The questionnaires were assigned to the laboratories which participated in the routine chemistry exter-nal quality assessment (EQA) programs proposed by National Health Commission for Clinical Laboratory. The questionnaires included general information of participants and information about unacceptable blood specimens. Participants were required to record all the in-formation concerning unacceptable blood specimen received from 1stto 31stJuly, 2017. The data from each laboratory were reported and collected via special online system.Results A total of 866 valid questionnaires were collected.Of 15 981 752 specimens received dur-ing the data collection period unqualified 122 00 specimens were rejected with overall rejection rate of 0.076%. The main reasons for unacceptable specimens were hemolysis (33.98%), insufficient specimen quantity (10.78%) and chylemia/lipemia (10.62%). The rejected specimens were related to the original laboratories, types of container and specimen, transportation manner and operating staff of blood collection. Conclusion Certain problems existed in the receiving and management system for unqualified blood specimen in our country and remaining to be perfected. The clinical laboratories should pay more attention for pre-examination stage, including routinely monitoring unacceptable specimens, analyzing related data at the most possible granular levels, identifying the main problem and taking effective measures.