1.Pleuropulmonary blastoma:one case report
Zhiguo CHEN ; Xianshu WANG ; Zhiguo YANG ; Fang YUE ; Feifei GAO
Journal of Clinical Pediatrics 2015;(3):251-253
ObjectiveTo investigate the early diagnosis and treatment of pleuropulmonary blastoma in children. Meth-ods The progress of pleuropulmonary blastoma from type 1 to type 3 was retrospectively analyzed.Results The male infant had no obvious abnormality in chest X-ray at 18 days. At one year old, X-ray iflm of the chest showed cystic lesions near hilum of the left lung (about 5 cm × 4 cm × 4 cm). The congenital cystic adenomatoid malformation was considered and an operation resection was suggested. However, it had been rejected by his parents. At 3 years and 2 months old, chest X-ray and CT showed left lung had a solid cystic lesion, the volume was signiifcantly enlarged, the back side was solid and the upper part had a large gas cavity. Two months later, the patient had asthmatic suffocation. The chest CT showed the tumor was completely solid. Pleuropulmonary blastoma type 3 was considered. The patient received the conventional chemotherapy after operation excision, and was followed up for 1 year. No recurrence was observed after the treatment.Conclusions Type 1 pleuropulmonary blastoma and congenital cystic adenomatoid malformation are hard to be differentially diagnosed. Early diagnosis and treatment of type 1 pleuropulmo-nary blastoma can improve the prognosis.
2.LOCALIZATION OF LACTATE DEHYDROGENASE C_4 IN HUMAN AND MOUSE SPERMS AND MOUSE TESTES
Yanxiang CHEN ; Zhiguo LIANG ; Panzao CHEN
Acta Anatomica Sinica 1955;0(03):-
Rabbit antisera against mouse LDH-C_4 were generated by immunization of rabbits with highly purified mouse lactate dehydrogenase C_4. Immunofluorescent localization of LDH-C_4 on mouse and human sperms was performed by rabbit antibodies against mouse LDH-C_4 at 1:20 dilution of antisera. Sheep anti-rabbit IgGFITC conjugates at dilution of 1:10 was used as second antibody for the detection. Human sperms were obtained from fresh semen of fertile males. Mouse sperms were prepared from epididymis fluid of mature mice. Both human and mouse sperms were thoroughly washed by PBS buffer. Sections of 4 ?m mouse testes were made and dried on the slides for the immunohistochemical localization, ?-hydroxy-n-valeric acid was used as specific substrate in incubation medium for revealing the LDH-C_4 activity. Immunofluorescent studies demonstrated that LDH-C_4 can be found on the surface of mouse and human spermatozoa. In human spermatozoa, the strong fluorescence was seen on the neck and midpiece. On mouse sperm, the antibody binding was directed toward the tail segment with little or no binding on the head or midpiece. Histochemical studies showed that the intensive formazen deposits were on the neck and midpiece of human and mouse spermatozoa, as well as the cells approximate to the lumen of mouse seminiferous tubules.
3.Effects of Modified Zhenxuan Granules on Blood Pressure and Endothelial Function of Spontaneously Hypertensive Rats
Zhiguo MIAO ; Baotian CHEN ; Congzhi LV
Traditional Chinese Drug Research & Clinical Pharmacology 2009;20(4):312-315
Objective To observe the effect of Modified Zhenxuan Granules (MZG) on blood pressure, synthesis and bioavail-ability of nitric oxide (NO), and plasma angiotensin I1 (Ang II) contents of spontaneously hypertensive rats (SHR). Methods Fiftymale SHR were randomly assigned to 5 groups: high-, middle-and low-dose MZG groups(at the doses of 37.50, 18. 70,and 9. 35 g/kg respectively), captopril (25 mg/kg) group and SHR control group. The rats received gastric gavage of corre-sponding medicine according to the experimental design for 12 weeks. Blood pressure from the tail was recorded at the beginning oftreatment and every 4 weeks during 12-weeks treatment. At the end of the experiment, the plasma NO and Ang II concentration,and aortal nitric oxide synthase (NOS) activity and aortal cyclic guanylic acid (cGMP) concentration were measured. ResultsMZG could decrease blood pressure and plasma Ang I1 concentration, increase plasma NO content, and enhance aortal NOS activ-ity and cGMP concentration ofSHR (P <0. 05, compared with the SHR control group), and high-dose MZG had the best effect.After treatment for 12 weeks, high-dose MZG had a similar effect on decreasing blood pressure compared with captoril group,had a better effect on increasing aortal cGMP (P< 0. 05), and increased the bioavailability of NO. Conclusion MZG can de-crease blood pressure, and its mechanism may be related to the improvement of NO/NOS/eGMP system and the decrease of plas-ma Ang Ⅱ concentration in SHR.
4.Investigation About Marking the Period of Validity on the Packing and Specifications of 369 Patent Chinese Materia Medica
Zhiguo ZHANG ; Chen CAO ; Qinglian CHEN ; Hong HU ; Lili WU
China Pharmacy 1991;0(02):-
OBJECTIVE:To gain a clear idea about the situation of marking the period of validity on the wrapper and specifications of patent Chinese materia medica(PCMM) in China METHODS:To investigate the period of validity marking on wrapper and internal packing of 369 commonly-used PCMM in our hospital RESULTS:The PCMM with period of validity marking accounted for 65 9% of total PCMM(usually 1 5~3 years) and those without period of validity accounted for 34 1% CONCLUSION: The absence of period of validity marking is very common,we should pay attention to it
5.Understanding quality roots in improvements within the laboratory:grasping quality starts within laboratory
Zhiguo WANG ; Yang FEI ; Wei WANG ; Haijian ZHAO ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2016;(1):4-6
Quality indicator is defined as the measure used to access the degree of inherent characteristics meeting the requirements .It is a powerful tool to improve laboratory quality to monitor and evaluate performance throughout critical steps in the total testing process .Targeted quality improvement can be obtained by quantizing quality levels in each phase when the quality indicators applied .Establishing and monitoring the quality indicators enables laboratory to compare over time between providers , and evaluate the effectiveness of delivered services and improving patient safety .
6.The effect of heat stress on the cytoskeleton and cell cycle of human umbilical vein endothelial cell in vitro
Zhiguo PAN ; Yu SHAO ; Yan GENG ; Jinghe CHEN ; Lei SU
Chinese Critical Care Medicine 2015;(8):639-642
ObjectiveTo study the effect of heat stress on the cytoskeleton and cell cycle of human umbilical vein endothelial cell (HUVEC) in vitro.Methods HUVEC was cultured in vitro in 5%CO2 medium at 37℃ (control group) or 43℃ (heat stress group) for 1 hour. Coomassie brilliant blue R-250 staining was used to determine the effect of heat stress on the cytoskeleton. The cells in heat stress group were subsequently cultured at 37℃in 5%CO2 medium after heat stress for 1 hour, and cell cycle of HUVEC was determined at 0, 6, 12, 18 and 24 hours with flow cytometry.Results Under light microscopy normal cytoskeleton was observed in control group, but thicker and shorter cytoskeleton was found after a rise of temperature, and stress fibers were found in heat stress group. The DNA content of HUVEC at all time points in G0/G1 stage was 38.07%-55.19% after heat stress. The DNA content in control group was 48.57%, and it was 54.06%, 55.19%, 48.23%, 38.07%, and 41.03% at 0, 6, 12, 18, 24 hours in G0/G1 stage in heat stress group. DNA content in S phase was 35.33%-48.18%. The DNA content in control group was 44.62%, and it was 35.33%, 39.50%, 42.50%, 48.18%, and 47.99% at 0, 6, 12, 18, 24 hours in S stage in heat stress group. DNA content in G2/M phase was 5.31%-13.75%. The DNA content in control group was 6.81, and it was 10.61%, 5.31%, 9.27%,13.75%, and 10.98% at 0, 6, 12, 18, 24 hours in G2/M stage in heat stress group. It was demonstrated that compared with control group, the DNA content in G0/G1 stage was significantly increased when the HUVEC were separated from heat stress within 6 hours, and it recovered at a similar level as control group at 12 hours.Conclusion Heat stress can change the cytoskeleton of HUVEC, and cause stagnation at G0/G1 stage in cell cycle.
7.Anti-metastasis Activity of Earthworm Fibrinolytic Enzyme on Hepatoma Cell in Vivo
Chunxia CHANG ; Hong CHEN ; Hong JI ; Zhiguo ZHANG
Traditional Chinese Drug Research & Clinical Pharmacology 2000;0(06):-
Objective To investigate the inhibitory effect of earthworm fibrinolytic enzyme (EFE) on the metastasis of human hepatoma cells.Methods A metastatic model of human hepatocellular carcinoma in nude mice via orthotopic implantation was established.After the modeling for 7 days,the mice were divided randomly into the control group,low-dose EFE group (800 uku/kg?d-1),and high-dose EFE group (1600 uku/kg?d-1).After administration for 30 days,the implanted tumors were weighted,and the intrahepatic transmission rate and abdominal cavity seeding rate were calculated after examination by naked eyes.Then the pulmonary metastasis were examined under microscope,and the expression of focus adhesion kinase (FAK) and ?1-intigrin were detected through RT-PCR and western blotting method.Results Compared with the model control group,the mean weight of the orthotopic tumor was reduced,and the intrahepatic transmission rate and abdominal cavity seeding rate were decreased in FEF groups (P
9.Fuzzy clustering analysis of inorganic elements in traditional Chinese medicines cured for vascular disease
Shunfu DONG ; Liqin HAN ; Zhiguo ZHU ; Zhonghang CHEN ; Hongbo DONG ;
Chinese Traditional Patent Medicine 1992;0(04):-
Objective: To apply fuzzy clustering analysis to determination of 10 inorganic elements and Cu/Zn ratio in 13 kinds of traditional Chinese medicine cured for vascular disease. Methods: By FAAS (flame atomic absorption spectrometry) sodium, calcium, magnesium, potassium, iron, chromium, nickel, manganese, copper and zinc were determined. By range analysis, correlation coefficients and relative fuzzy matrix were calculated.Results: Correlation coeffieients ? were mostly in the range of 0.55~0.80, especially ?=0.95 between Buzhangnaoxintong Capsule and Xinbao Pill. Conclusion: On condition that trace and macro elements are relatively rich and clustering correlation coefficients are larger, therapentic effects among traditional Chinese medicines cured for vascular disease are also similar. This suggests that trace elements, macro elements and Cu/Zn ratio have much to do with therapeutic effect.
10.Linear measurement accuracy using cone-beam computed tomography for human skull
Xiaolin SUN ; Xuejin WANG ; Zhiguo CHEN ; Lei JIN
Chinese Journal of Tissue Engineering Research 2014;(20):3252-3256
BACKGROUND:Cone-beam computed tomography has been widely applied in the dentistry due to irreplaceable advantages. Among those advantages, linear measurement is one of the important ones. Further studies are suggest to explore the accuracy and repeatability of linear measurement for the whole skul , as wel as the effect of different resolution and scanning thickness on the linear measurement results.
OBJECTIVE:To evaluate the accuracy of linear measurement using cone-beam computed tomography (Newtom VG) on the human skul , with two different voxel sizes.
METHODS:In this study, 22 anatomic landmarks in four dry human skul s were marked and 11 linear measurements were obtained. These were considered to be the gold standard (real measurement). The skul s were scanned by cone-beam computed tomography (Newtom VG) at two voxel sizes:0.3 mm and 0.15 mm. Linear measurement was performed in axial and coronal planes. SPSS software version 17 was used for data analysis between radiographic measurement and real measurement.
RESULTS AND CONCLUSION:The mean differences of real and radiographic measurements were-0.27 to 0.14 in four different sections, and statistical analysis showed no significant difference between linear measurements and gold standard (P>0.05). There was no significant between two different voxel sizes (P>0.05). Cone-beam computed tomography (Newtom VG) is highly accurate and reproducible in linear measurements in the axial and coronal planes. A cone-beam computed tomography scan with a larger voxel size (0.3 mm) is recommended, resulting in lower radiation dose and faster scan time.