1.The multi-channel digital measurement technology for temperature and its application
Meisheng SHI ; Yang LIU ; Zhenxing SONG ; Nanlin WANG
Chinese Medical Equipment Journal 1989;0(01):-
The multi-channel digital measurement technology for temperature is developed on the basis of the combination of digital measurement technology for temperature and the 1-wire technology. This paper discusses this technology and applies it to designing a system for multi-channel digital temperature measurement. This system has already been used in the research of some kind of medical equipments. It can conquer such problems as overhigh consumption of time and labor, difficult condition when applied to measuring microenvironment temperature within a cold or hot zone.
2.Development of WMZ-03 anaesthesia workstation with chest intergrated with apparatus
Taihu WU ; Zhenxing SONG ; Zhen WAN ; Xiaofeng ZHANG
Chinese Medical Equipment Journal 1989;0(03):-
This paper introduces a type of anaesthesia workstation which is composed of two vertical medical chests, i.e. the upper and lower parts. Taken out of the chest, the two parts are butted against and locked to make the workstation ready for operation. After operation is finished, the two parts are uncoupled and put into the chests, and then the workstation can be stored and transported with the chests closed.
3.Study on anti-shock trousers
Taihu WU ; Zhenxing SONG ; Wei WEI ; Xiaofeng ZHANG ; Shutian GAO
Chinese Medical Equipment Journal 1989;0(04):-
This paper introduces a novel trousers,whose theory is to drive blood by inflated pressure.Being light-weight,small and effective,easy to carry,store and operate,it is postured for first aid and resuscitation of hospital patients with severe shock,and also can be applied to bleeding remission,hemorrhagic as well as fracture immobilization.
4.Study of one-handed electronic tourniquet
Zhenxing SONG ; Taihu WU ; Yundou WANG ; Meisheng SHI
Chinese Medical Equipment Journal 1993;0(06):-
This paper introduces a small and light one-handed electronic tourniquet which adds the function of electronic timing and alarming to the traditional locked tourniquet. The tourniquet has an effect on first aid hemostasis from extremity wound in emergency.
5.Improving Design of Multichannel Digital Temperature Detecting System
Ping CHEN ; Meisheng SHI ; Zhenxing SONG ; Yuhua MENG
Chinese Medical Equipment Journal 1993;0(05):-
Objective To solve problems existing in multichannel digital temperature detecting system,including boring wiring,unreliable data storage,poor anti-jamming.Methods Dynamic address code design and automatic compositor algorithms were integrated into the software design,while the running out was eliminated by adopting watch dog chip.Results The validity of the improvement were proved by high & low temperature tests.Conclusion The improved system,with convenient wiring,reliable data storage,accurate results and short response time,can be applied to fully digital & unattended temperature detection.
6.Design of Integrated Emergency Medical Treatment System Mounted on Helicopter
Taihu WU ; Haifeng XIAO ; Xingju MENG ; Zhenxing SONG ; Jiewen ZHEN
Chinese Medical Equipment Journal 1993;0(06):-
Objective To design an integrated emergency medical treatment system mounted on helicopter, which can meet the requirements of field treatment and evacuation in emergency disasters or local wars, the system has immobile form and mobile form. Methods With the characteristics of existing helicopter considered, the components of the system were supposed to include a universal stretchers, overall structure and embedded emergency devices and support transport accessories. Results The system could realize the destination of swift response and air-and ground first-aid, the new model of swift response can made the regulation and principle of first -aid more reasonable, and increases the survival rate significantly. Conclusion Critical diseases have become the latest killer in daily life. The first-aid on spot need the new model of swift response and air -and ground first -aid, the system can decrease the invalidity and mortality.
7.Design and research of intelligent system for triage
Dan WANG ; Guang ZHANG ; Feng CHEN ; Zhenxing SONG ; Haitao WANG ; Hengzhi LU ; Yalin WANG ; Taihu WU
Military Medical Sciences 2015;(9):651-655
Objective To develop an intelligent system which is able to offer an optimized emergency treatment recommendation for fast triage automatically.Methods An algorithm and intelligent platform for grading injury were developed based on physiological signal collecting technology, intelligent grading algorithm and integration technology.A comparison between this system and traditional methods was made.Results This intelligent system was able to increase accuracy by 21%and took only 48%of the time taken by traditional methods.There was significant difference between the two groups(P=0.038<0.05).Conclusion The accuracy of the triage is improved by this intelligent system that is less time-consuming.With this device, the injury statement can be identified quickly and the targeted medical treatment can be performed accurately.The efficiency of emergency treatment in case of disaster will thus be dramatically increased.
8.Design and protection evaluation of air purification system in intensive care ambulance
Yajun LIU ; Taihu WU ; Zhenxing SONG ; Shulin TAN ; Fu NIU ; Jinggong SUN
Military Medical Sciences 2016;40(9):738-741
Objective To design and develop an air purification system for intensive care ambulances,which can effectively purify the air in the compartment and sterilize the microbes in the air.Methods By integrating titanium dioxide photocatalysts with air filtration materials,an air purification system was designed that was capable of effective sterilization of microbes in the air via photocatalytic oxidation and decomposition,and of effective filtration of particles in the air through HEPA filters.The protection effect was evaluated by air filtration and sterilization tests in accordance with the related national standards.Results The air cleanliness could reach the 100 000 level with bacteria counts no more than 1 CFU per pan for 15 minutes in the ambulance compartment when the air purification system worked normally,which could meet the demands of environmental hygienic standards for intensive care units.Conclusion The air purification system can effectively purify and sterilize the air in the compartment of an intensive care ambulance.The effects of air purification meet the requirements of related hygienic standards,which can satisfy the demands of treatment and intensive care for the victims in the ambulance.
9.Qualitative and quantitative study of Shengui anti-pruritic mixture
Wei GONG ; Xu SUN ; Kun ZHANG ; Zhenxing ZHANG ; Xinxin ZHANG ; Yuping ZHOU ; Zheng WANG ; Yingchun SONG
International Journal of Traditional Chinese Medicine 2018;40(3):251-257
Objective To study the qualitative and quantitative standard of Shengui anti-pruritic mixture. Mehtods Sophorae Flavescentis Radix, Cnidii Fructus, Polygoni Multiflori Radix, Astragali Radix, Paeoniae Radix Alba and Glycyrrhizae Radix Et Rhizoma were identified by TLC.The contents of matrine and ferulic acid were determined by HPLC. Results The TLC showed the obvious characteristics with the spots clear and well-separated with no interference by negative control. Matrine showed a good linear relationship at 0.062 5- 2.500 0 μg (r=0.999 9) with a good meeting of adding sample recovery test. Ferulic acid showed a good linear relationship at 0.021 0-0.840 0 μg (r=0.999 9) with a good meeting of adding sample recovery test. Conclusions The method is easy-operated and accurate which showed a good specificity for the quality control of Shengui anti-pruritic mixture.
10.Ultrasound guided injection of platelet-rich plasma for intratendinous rotator cuff tear: clinical and radiological outcomes
Yulei LIU ; Ligang CUI ; Qingfa SONG ; Mengsai LIU ; Zhenxing SHAO ; Guoqing CUI
Chinese Journal of Orthopaedic Trauma 2023;25(8):696-701
Objective:To investigate the clinical and radiological outcomes of ultrasound guided injection of platelet-rich plasma (PRP) in the treatment of intratendinous rotator cuff tear.Methods:A retrospective study was conducted to analyze the clinical data of 43 patients (46 shoulders) who had been treated for intratendinous partial-thickness rotator cuff tear by ultrasound guided injection of PRP consecutively from July 2021 to March 2022 at Department of Sports Medicine, Peking University Third Hospital. There were 23 males and 20 females, with an age of (47.8±13.5) years and a course of disease of 6 (4, 18) months, involving 22 left shoulders and 24 right shoulders. The visual analog scale (VAS) pain score, the University of California at Los Angeles (UCLA) rating scale, and the shoulder index of the American Shoulder and Elbow Surgeons (ASES) were determined before injection and at the last follow-up. The changes in tear size were also evaluated by magnetic resonance imaging (MRI) before PRP injection and 3 to 5 months after PRP injection.Results:The 43 patients were followed up for 15 (12, 17) months after treatment. Of this cohort, 7 shoulders (15.2%, 7/46) were recovered to complete normal and very satisfied with the injection effects while 19 shoulders(41.3%, 19/46) satisfied with the effects after injection, yielding an overall satisfaction rate of 56.5% (26/46). At the last follow-up, the VAS score [3.0 (2.0, 4.0) points], ASES score [80.0 (65.0, 88.8) points], and UCLA score [29.0 (20.0, 32.0) points] were significantly improved compared with those before injection [5.5 (4.0, 8.0) points, 55.0 (39.2, 65.0) points, and 16.0 (12.0, 20.3) points] ( P < 0.05). MRI evaluation showed the tear volume was significantly reduced after PRP injection [46.1 (20.9, 77.5) mm 3 before injection versus 28.2 (12.5, 63.6) mm 3 after injection] ( P<0.05), and a >50% tear volume diminution was observed in 13 shoulders (34.2%,13/38). There were no complications during or after injection. Conclusion:As the ultrasound guided injection of PRP into intratendinous lesions is effective and safe for patients with intratendinous partial-thickness rotator cuff tear, it can be an alternative treatment for the patients or professional athletes who are unwilling to undergo surgery.