1.Research on Stability and Bio-safety of Warming Moxibustion Gel-unguentum
Ying WU ; Yuting YIN ; Yirou QIAN ; Zhenglin ZHU
China Pharmacist 2014;(2):207-209
Objective:To evaluate the stability and bio-safety of warming moxibustion gel-unguentums( WMG) . Methods: With the commercially available package and at 40℃ ± 2℃, RH (75% ± 5%) for six months,the stability of WMG was inspected. Guinea pig skin sensitization test, rabbit skin irritation test and cell toxicity test were used to investigate the safety. Results:Compared to the results of 0 month, there was no difference in the sample character, containing paste percentage, adhesion, shape, weight difference and all theindices in TLC identification. Cell toxicity test showed that WMG had slight cytotoxicity. Guinea pig skin sensitization test and rabbit skin irritation test indicated that the grade of skin reaction was zero and the primary stimulus index of skin tissues was also zero. Conclusion:The quality of WMG is stable and the production preparation technology is feasible. Moreover, it is safe in transder-mal administration.
2.Clinical study of spiral stone basket assisted with FURL in treatment of unilateral upper ureteral stones for diameter>1.0 cm
Yijun ZHOU ; Xishan ZHU ; Xiaonong DAI ; Zhenglin ZHANG ; Kefeng WANG
China Journal of Endoscopy 2017;23(1):61-64
Objective To investigate the clinical effects and safety of spiral stone basket assisted with FURL in the treatment of unilateral upper ureteral stones for diameter>1.0 cm. Methods 140 patients with unilateral upper ureteral stones for diameter>1.0 cm from January 2012 to December 2015 were randomly divided into control group (70 patients) with FURL used alone and observation group (70 patients) with spiral stone basket assisted application on the basis of control group;the perioperative clinical indicators, the lithotripsy success rate, the stone clearance rate, the stone removal rate and the postoperative complication incidence of both groups were compared. Results The operation time of observation group was signiifcantly longer than control group (P<0.05). There was no signiifcant difference in the blood loss volume in operation and hospitalization time between 2 groups (P>0.05). The lithotripsy success rate and the stone clearance rate of observation group was signiifcantly higher than control group (P<0.05). The stone removal rate of observation group was signiifcantly lower than control group (P<0.05). The postoperative complication incidence of observation group was no difference between 2 groups (P> 0.05). The total treatment expenses of observation group was signiifcantly fewer than control group (P<0.05). Conclusion Spiral stone basket assisted with FURL in the treatment of unilateral upper ureteral stones for diameter>1.0 cm can efifciently higher the stone removal effects, reduce the stone removal risk and not increase the postoperative complications incidence.
3.Discussion on the reference range of thromboelastogram in 916 healthy adults in Shenzhen area
Weicheng LI ; Kunlun WU ; Siqi CAI ; Guodu ZHU ; Yubao ZHONG ; Yunjing XU ; Nansheng CAI ; Lili WU ; Zhenglin WU
Chinese Journal of Blood Transfusion 2022;35(3):304-307
【Objective】 To determine the reference range of thromboelastogram(TEG) and establish a TEG feature for local population by measuring TEG parameters in healthy adults in Shenzhen comparing the difference between gender and age, and analyzing the reference data provided by reagent manufacturer. 【Methods】 A total of 916 healthy adults, aged between 19 to 59, who did their regular health checks in our hospital from September 2020 to August 2021 were selected. The TEG(from Lepu Medical Technology Co., Ltd.) was performed, and the clot reaction time(R), clot formation time(K), coagulation angle(α-Angle), maximum amplitude(MA), coagulation index(CI), fibrinolysis index LY30 and the estimated percent lysis (EPL) were analyzed. 【Results】 The reference ranges of TEG parameters, including R, K, α-Angle, MA, CI, LY30 and EPL, of 916 healthy adults from Shenzhen were 3.25~8.19 min, 0.66~3.18min, 47.70~76.56deg, 50.05~72.91mm, -4.3~3.4, 0~2.2% and 0~3%, respectively. The value of α-Angle, CI, K, LY30, MA and R didn’t all meet the given range provided by the manufacturer; some were exceeding and some inferior to. A total of 227 out of 916 individuals presented abnormal results, relative to the references, in at least one parameter, and 78 were diagnosed of abnormal coagulation based on the given reference range, with a specificity of 75.2%. 【Conclusion】 The reference range of TEG parameters of Shenzhen locals is significantly different from that provided by manufacturers. And it is imperative for local TEG laboratories to establish their own reference ranges according to age and gender groups based on local population characteristics.