1.Clinical observation of Van Herick method for evaluating anterior chamber angle width
Peng ZHANG ; Lifang WANG ; Yanzheng WANG ; Kunling HAN ; Zhaoyang REN ; Yanling WANG
International Eye Science 2024;24(1):136-139
AIM: To explore a more convenient and accurate method for evaluating the anterior chamber angle width based on the Van Herick method.METHODS:A total of 58 patients(69 eyes)with age-related cataract who visited our hospital between January and December 2021 were included. They were divided into the chamber angle width ≥1/2 corneal thickness(CT)group(44 eyes of 37 cases)and <1/2CT group(25 eyes of 21 cases)according to the Van Herick method. The central anterior chamber depths and the peripheral anterior chamber angle degrees were measured by ultrasound biomicroscopy.RESULTS: There were statistically significant differences in central anterior chamber depth between the two groups(2.64±0.27 mm vs. 2.23±0.29 mm, P<0.01), and the differences of chamber angle degrees of quadrants of superior, temporal, inferior and nasal compared between two groups were all statistically significant(P<0.01). The difference of chamber angle degrees of quadrants of superior and inferior in chamber angle width ≥1/2CT group was not statistically significant(P>0.05), while the differences of chamber angle degrees of other quadrants were all statistically significant(P<0.05). The differences of chamber angle degrees of quadrants of superior and nasal, temporal and the chamber angle degrees of quadrants of inferior and temporal were all statistically significant in chamber angle width <1/2CT group(P<0.05).CONCLUSION: In the overall evaluation of the anterior chamber angle, it would be more simple, fast and accurate when evaluating the temporal chamber angle width and inferior quadrant of chamber angle width by using the Van Herick method under silt lamp.
2.Application value of virtual reality laparoscopic simulator training in laparoscopic transabdo-minal preperitoneal hernioplasty : a prospective study
Jingjing HUANG ; Ye JIN ; Jiaming LIU ; Han LIN ; Yifeng CUI ; Zhaoyang LU
Chinese Journal of Digestive Surgery 2024;23(9):1209-1213
Objective:To investigate the application value of virtual reality laparoscopic simulator training in laparoscopic transabdominal preperitoneal hernioplasty (TAPP).Methods:The prospective cohort study was conducted. Twenty young physicians from The First Affiliated Hospital of Harbin Medical University with ≥3 years of clinical experience in general surgery and no foundation in laparoscopy were selected for training during July to August 2023. Physicians were divided into two groups based on random number table method. Physicians undergoing virtual reality laparoscopic simulator training were divided into the virtual reality group, and physicians undergoing regular laparoscopic simulator training were divided into the regular group. Two groups of physicians were trained using laparoscopic simulator for 10 days (2 hours for each skill, with a total of 6 hours per day for 3 skills), and the training covered basic laparoscopic surgical skills such as clamping, cutting and suturing and knotting. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups were conducted using the independent sample t test and the paired ttest was used for intra group comparison. Measurement data with skewed distribution were represented as M(range). Count data were described as absolute numbers, and comparison between groups were conducted using the chi-square test. Results:(1) Physicians situation before training. A total of 20 physicians were selected for eligibility. There were 13 males and 7 females, aged 31(range, 30?34)years. There are 7 males and 3 females in the virtual reality group, with age of (31.5±1.4)years and the TAPP simulation surgery time of (42±4)minutes before training. There are 6 male and 4 female students in the regular group, with age of (31.2±1.0)years and the TAPP simulation surgery time of (42±4)minutes before training. There was no significant difference in gender, age, TAPP simulation surgery time between the two groups of physicians ( P>0.05), confounding bias ensured comparability. (2) Basic skills of physicians before and after training. For physicians in the virtual reality group, the clamping score was 5.1±1.0, the cutting score was 4.9±1.0, the suturing and knotting score was 4.7±1.5 before training. The clamping score was 8.0±1.3, the cutting score was 7.9±1.5, the suturing and knotting score was 6.6±1.3 after training. There were significant differences in the above indicators before and after training ( t=?5.75, ?5.21, ?3.07, P<0.05). For physicians in the regular group, the clamping score was 5.3±1.0, the cutting score was 5.0±1.2, the suturing and knotting score was 4.3±1.5 before training. The clamping score was 7.1±1.2, the cutting score was 6.7±1.3, the suturing and knotting score was 5.7±1.1 after training. There were significant differences in the above indicators before and after training ( t=?3.73, ?3.16, ?2.42, P<0.05). (3) Completion of simulated surgical situations before and after training. The time of completing TAPP simulation surgery for virtual reality group after training was (29±3)minutes, versus (42±4)minutes before training, showing a significant difference before and after training ( t=7.69, P<0.05). The time of completing TAPP simulation surgery for regular group after training was (36±4)minutes, versus (42±4)minutes before training, showing a significant difference before and after training ( t=3.75, P<0.05). The time of completing TAPP simulation surgery of virtual reality group after training was shorter than that of regular group, showing a significant difference between the two groups ( t=?3.89, P<0.05). Conclusion:Both of virtual reality and regular laparoscopic simulator can enhance the basic laparoscopic surgical skills and the proficiency of TAPP simulation surgery of physicians, and the training effect of virtual reality laparoscopic simulators is better.
3.Exploration on the Mechanism of Marsdenia tenacissima against Breast Cancer Based on Network Pharmacology and Experimental Verification
Juan ZHAO ; Zhaoyang MENG ; Qinfang ZHU ; Lanyi WEI ; Lingyan XU ; Yonglong HAN ; Junjun CHEN
Chinese Journal of Information on Traditional Chinese Medicine 2024;31(9):24-32
Objective To explore the mechanism of Marsdenia tenacissima in the treatment of breast cancer through network pharmacology and experimental verification.Methods Literature retrieval was conducted to obtain the active components of Marsdenia tenacissima.The SwissTargetPrediction database was used to predict the potential targets of these active components.Targets of breast cancer were obtained from GeneCards,GEPIA2,OMIM,PharmGKB and TTD databases.The intersection targets were obtained,and a Marsdenia tenacissima-breast cancer-targets network was constructed using Cytoscape 3.9.0 software.The core targets were identified through protein-protein interaction(PPI)network analysis,followed by GO and KEGG pathway enrichment analysis to screen relevant signaling pathways.Molecular docking validation was performed for the top 10 key targets and major active components.The human breast cancer cell line MDA-MB-231 was treated with Marsdenia tenacissima injection in vitro.Cell proliferation ability was detected by CCK-8 assay and colony formation assay.Cell apoptosis was detected by Calcein-AM/PI staining and flow cytometry.Cell migration ability was detected by Transwell assay.Western blot experiment was used to validate the PI3K-AKT signaling pathway.Results Totally 37 active components and 276 potential targets against breast cancer were screened from Marsdenia tenacissima,including 11alpha-O-Benzoyl-12beta-O-acetyl tenacigenin B,Caffeic acid,Drevogenin A and Kaempferol.25 core targets were screened by PPI network such as AKT1,EGFR,TNF,CTNNB1 and IL-6,which mainly affected the estrogen signaling pathway,ErbB signaling pathway,HIF-1 signaling pathway and PI3K-AKT signaling pathway,etc.The molecular docking results showed that the main active components of Marsdenia tenacissima exhibited good binding activities with the core targets AKT1,ALB,CASP3,ESR1 and TNF.The results of in vitro experiments showed that Marsdenia tenacissima injection could inhibit the proliferation and migration ability of MDA-MB-231 cells(P<0.01,P<0.001)and induce apoptosis(P<0.001),as well as inhibit the activation of PI3K-AKT signaling pathway(P<0.05,P<0.01).Conclusion Marsdenia tenacissima may exert its anti-breast cancer effects through multiple targets and pathways,and the mechanism may be related to the inhibition of PI3K-AKT signaling pathway.
4.Near-infrared excited graphene oxide/silver nitrate/chitosan coating for improving antibacterial properties of titanium implants.
Yifan WANG ; Yingde XU ; Xuefeng ZHANG ; Jingyu LIU ; Jintong HAN ; Shengli ZHU ; Yanqin LIANG ; Shuilin WU ; Zhenduo CUI ; Weijia LÜ ; Zhaoyang LI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):937-944
OBJECTIVE:
To design and construct a graphene oxide (GO)/silver nitrate (Ag3PO4)/chitosan (CS) composite coating for rapidly killing bacteria and preventing postoperative infection in implant surgery.
METHODS:
GO/Ag3PO4 composites were prepared by ion exchange method, and CS and GO/Ag3PO4 composites were deposited on medical titanium (Ti) sheets successively. The morphology, physical image, photothermal and photocatalytic ability, antibacterial ability, and adhesion to the matrix of the materials were characterized.
RESULTS:
The GO/Ag3PO4 composites were successfully prepared by ion exchange method and the heterogeneous structure of GO/Ag3PO4 was proved by morphology phase test. The heterogeneous structure formed by Ag3PO4 and GO reduced the band gap from 1.79 eV to 1.39 eV which could be excited by 808 nm near-infrared light. The photothermal and photocatalytic experiments proved that the GO/Ag3PO4/CS coating had excellent photothermal and photodynamic properties. In vitro antibacterial experiments showed that the antibacterial rate of the GO/Ag3PO4/CS composite coating against Staphylococcus aureus reached 99.81% after 20 minutes irradiation with 808 nm near-infrared light. At the same time, the composite coating had excellent light stability, which could provide stable and sustained antibacterial effect.
CONCLUSION
GO/Ag3PO4/CS coating can be excited by 808 nm near infrared light to produce reactive oxygen species, which has excellent antibacterial activity under light.
Chitosan
;
Silver Nitrate
;
Titanium
;
Anti-Bacterial Agents/pharmacology*
;
Coloring Agents
5.Diagnosis and treatment recommendations of dialysis patients with SARS-CoV-2 infection for primary care clinicians
Rongguo FU ; Zhao CHEN ; Lining JIA ; Li WANG ; Jin HAN ; Lifang TIAN ; Xianghui CHEN ; Linting WEI ; Fuqian LEI ; Jiamei LU ; Xiaoqin MA ; Li ZHAO ; Shizhuo WEI ; Jing LIU ; Zhaoyang DUAN ; Jie GAO
Journal of Xi'an Jiaotong University(Medical Sciences) 2023;44(3):353-360
End-stage renal disease (ESRD) patients undergoing outpatient hemodialysis (HD) and home peritoneal dialysis (PD) are high risk population of severe and critical types caused by SARS-CoV-2 infection. In order to improve the quality of diagnosis and treatment in dialysis patients with SARS-CoV-2 infection, we wrote this recommendation for primary care clinicians. During the epidemic period of SARS-CoV-2 infection, all patients should be instructed to strengthen self-management. Once the SARS-CoV-2 infection was found in dialysis patients, early stratified management should be carried out within 72 hours after the first positive nucleic acid or antigen test results, which includes early antiviral therapy, early recognition, and transferring severe patients from community or primary hospital to a referral hospital promptly. Guidance for dietary and sports rehabilitation after SARS-CoV-2 infection should also be started as soon as possible.
6.Preparation, characterization and application of adipose tissue extracellular matrix derived hydrogel
Zhaoyang CHEN ; Jun SHU ; Ran TAO ; Yan HAN
Chinese Journal of Plastic Surgery 2022;38(1):104-108
Extracellular matrix hydrogel has been widely used in three-dimensional cell culture, organoid construction, tissue defect repair, biological three-dimensional printing and tissue engineering due to its excellent bioactivity, biocompatibility, bioinducibility, biodegradability and minimally invasive injection. Adipose tissue has the advantages of sufficient sources, easy access, and rich content of extracellular matrix components. It has become a research hotspot in the field of tissue repair and regenerative medicine in recent years. This article reviews its preparation, detection and application, in order to provide a reference for relevant researchers.
7.Preparation, characterization and application of adipose tissue extracellular matrix derived hydrogel
Zhaoyang CHEN ; Jun SHU ; Ran TAO ; Yan HAN
Chinese Journal of Plastic Surgery 2022;38(1):104-108
Extracellular matrix hydrogel has been widely used in three-dimensional cell culture, organoid construction, tissue defect repair, biological three-dimensional printing and tissue engineering due to its excellent bioactivity, biocompatibility, bioinducibility, biodegradability and minimally invasive injection. Adipose tissue has the advantages of sufficient sources, easy access, and rich content of extracellular matrix components. It has become a research hotspot in the field of tissue repair and regenerative medicine in recent years. This article reviews its preparation, detection and application, in order to provide a reference for relevant researchers.
8.Repair of sciatic nerve defect in rats by adipose tissue decellularized matrix hydrogel
Yan LI ; Zhaoyang CHEN ; Youbai CHEN ; Jing REN ; Zehao NIU ; Wenwen PU ; Yan HAN
Chinese Journal of Microsurgery 2021;44(3):292-297
Objective:To observe the effect of adipose tissue decellularized matrix hydrogel (DAT-gel) on the repair of sciatic nerve defect in rats.Methods:From April, 2019 to April, 2020, aseptic granular adipose tissue was collected from healthy adult women who underwent thigh or abdominal liposuction in the Department of Plastic Surgery, the First Medical Centre of the PLA General Hospital. Decellularisation and enzymatic digestion of adipose tissue were performed to prepare DAT-gel. Scanning electron microscope (SEM) was used to observe the ultrastructure of the hydrogel, and rheology was employed to test the gel dynamics and viscoelasticity of the hydrogel. A rat model of sciatic nerve defect was established and randomly divided into 3 groups: simple chitin catheter group (Chitin group), DAT-gel plus chitin catheter group (DAT-gel group) and autologous nerve reverse connection group (Autograft group) with 10 rats in each group. At the 12th week after surgery, the general view, function and morphology of the regenerated nerve were observed to evaluate the repairing status of the injured nerve. One-way analysis of variance (one-way ANOVA) was used for data analysis. If the difference between the groups was statistically significant, the Turkey method was further used for pairwise comparison. P<0.05 was considered as statistically significant. Results:The results of SEM showed that the DAT-gel had a three-dimensional structure in porous fibre network. The results of rheological test results showed that the complex viscosity of the hydrogel at 4 ℃ and 37 ℃ were 148.91 mPa·s and 801.29 mPa·s, respectively. DAT-gel underwent a sol-gel phase transition when the temperature had been increased. The results showed that DAT-gel had a good temperature-sensitive effect, and its critical point of sol-gel phase transition was similar to the internal temperature of rat. The results of animal experiments showed that the morphology and function of the regenerated nerve in the DAT-gel group were superior to Chitin group at 12 weeks after surgery, according to macroscopic view of the regenerated nerve, electrophysiology of the nerve, the morphology of the new axon and the target muscle, etc.. There was statistically significant between groups ( P<0.05). Conclusion:DAT-gel can significantly promote a repair of sciatic nerve defects in rats.
9.Study on the influence of sleeve height and implant length on accuracy of static computer-assisted implant surgery
Qingfu WANG ; Zhengdi HE ; Haiyang YU ; Xiaohai QIU ; Yanying WANG ; Jing HAN ; Jing YANG ; Xiaodi SUN ; Xiaoban LI ; Zhaoyang LI ; Hui FAN ; Jian ZHANG
Chinese Journal of Stomatology 2020;55(11):902-907
Objective:To evaluate the influence of the sleeve lengths and implant lengths on accuracy of static computer-assisted implant surgery (sCAIS).Methods:Twenty-eight models of bilateral mandibular single tooth loss were included. Fifty-five implants were placed under the guidance of sCAIS (Straumann Bone Level 4.1 mm×10 mm). According to the height of metal sleeve of static guide plate, 55 implants were divided into 11 groups (free hand group, 1 mm group, 2 mm group, 3 mm group, 4 mm group, 5 mm group, 6 mm group, 7 mm group, 8 mm group, 9 mm group, 10 mm group), with 5 implants in each group. Eight research models were included. Group with 5 mm sleeve guides were used to place implants of different length, (Straumann Bone Level width 4.1 mm, height was 8 mm, 10 mm and 14 mm), 5 implants in each group. Eighteen patients with mandibular single tooth loss were included in the Department of Oral Implantology, Tianjin Stomatological Hospital from October 2018 to June 2019. There were 10 males and 8 females, 18-46(33.7±7.9) years old. A total of 18 implants were implanted and divided into 3 groups (free hand group, 3 mm group and 5 mm group) with 6 implants in each group. Digital software was used to compare the implant positions before and after implantation. Non-parametric Kruskal-Wallis test or one-way ANOVA were used to analyze the results.Results:There was no significant difference in implant vertical deviation between different sleeve height groups (1-10 mm) and free hand group, but the neck deviation in free hand group[(1.04±0.13) mm] was significantly higher than that in different sleeve height groups (1-10 mm) ( P<0.05). The tip deviations of free hand group, 1 mm group and 2 mm group [(1.32±0.43), (0.83±0.10) and (0.78±0.11) mm, respectively] was significantly higher than that of 10 mm group [(0.31±0.14) mm]( P<0.05). The angle deviation of free hand group and 1 mm group (3.99°±0.85° and 2.59°±0.69°), respectively] was significantly higher than that of 10 mm group (0.61°±0.03°) ( P<0.05). The tip deviations of implants in the 14 mm group [(0.83±0.22) mm] was significantly higher than that in the 8 mm and 10 mm groups [(0.44±0.07) and (0.49±0.06) mm, respectively]. Clinical studies showed that there was no significant difference in neck deviation, tip deviation and angle deviation between 3 mm group and 5 mm group ( P>0.05), but deviations were significantly lower than those in free hand group ( P<0.05). Conclusions:The length of the sleeves has significant influence on the accuracy of the surgical guide. There was no significant difference in accuracy of the implant guide with 3 mm or 5 mm metal sleeves. The vitro study has some limitations and needs further systematic research.
10. Application of multislice computed tomography volume rendering and 3D printing technique of costal cartilage for auricular reconstruction
Zhaoyang CHEN ; Chuncai LUO ; Xiao SHANG ; Hongyan YANG ; Li YANG ; Hasi WULAN ; Yan HAN
Chinese Journal of Plastic Surgery 2017;33(2):97-101
Objective:
To investigate the value of Multislice computed tomography volume rendering(VR) technique and 3D printing technique in auricular reconstruction.
Methods:
Six patients were enrolled for auricular reconstruction with costal cartilage, including 5 congenital microtia patients and 1 traumatic auricular defect patient. We harvest the three-dimensional reconstructive data of the contralateral sixth, seventh, eighth and ninth costal cartilage with VR technique. Three-dimensional solid models were 3D printed with nylon material according to the data exported in STL format. Preoperative simulation was performed on the models, accordingly, we determined the strategies of costal cartilage harvest and framework fabrication, and operations were performed based on the pre-designed plan.
Results:
In all 6 patients, the actual costal cartilage harvest and framework fabrication process was consistent with the preoperative design and simulation results, and more scientific than before. The shapes of reconstructed ears were vivid and natural. No complications such as infection, absorption, distortion and chest deformity happened.
Conclusions
Through costal cartilage VR and 3D printing technique, we could make more reasonable preoperative design and simulation. The results can be improved with reduced injury, while avoiding the risks of thoracic deformity.

Result Analysis
Print
Save
E-mail