1.Clinical effect of dental pulp inactivative agent Depulpin in deciduous teeth
Journal of Practical Stomatology 2009;25(4):593-594
To observe the clinical effects of Depulpin in deciduous teeth. It was suggested that Depulpin was an effective and safe drug for pulp devitalizer in children.
2.The application of ASIR combined with automatic tube current modulation in low-dose chest CT screening
Hui TANG ; Taiping HE ; Yangyang YAN ; Dong HAN ; Zhanli REN ; Yongjun JIA ; Nan YU
Journal of Practical Radiology 2018;34(1):109-113
Objective To explore the clinical value of adaptive statistical iterative reconstruction(ASIR)combined with automatic tube current modulation in low dose scan of chest CT.Methods 80 patients who underwent chest CT scan were randomly divided into four groups,with a noise index(NI)of 14,16,18,and 20,respectively.Automatic tube current modulation technique for chest CT scan was adopted for all patients.The standard dose group,with a NI of 14,was reconstructed with FBP.While the low-dose groups,with a NI of 16,18 and 20,were reconstructed with four ASIR levels(20% ASIR,40% ASIR,60% ASIR and 80% ASIR) in each group.The volume CT dose index(CTDIvol),dose length product(DLP)and effective dose(ED)were recorded of the four groups.The signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)were calculated of the different reconstruction groups. Two radiologists with more than five years of work experience blindly scored the subjective image quality.Results Effective dose of the four groups with different NI were(3.29 ± 1.21)mSv,(3.10 ± 1.07)mSv,(2.20 ± 0.82)mSv and(1.97 ± 1.21)mSv,respectively. In all the reconstruction groups,when NI was constant,the greater the ASIR,the lower the SD.When ASIR percentage was constant, the SD was increased and the SNR was reduced along with NI rising up.When the parameters were set as NI 18 and ASIR 60%,the SD would be smaller and SNR would be higher than that of a standard dose group.In aspect of the scores from subjective image quality evaluation,there was no significant difference(P> 0.05).The average ED was decreased by about 33.2% when compared to the standard dose group.Conclusion Combining automatic tube current modulation with ASIR has a certain clinical practicality.When the NI is set at 18 and ASIR is 60%,the image quality can be optimal for not only satisfying the requirements of clinical diagnosis, but also reducing radiation dose in chest CT scanning.
3.The effect of deep learning image reconstruction combined with"double-low"technique on the image quality of coronary CT angiography in overweight patients
Li SHEN ; Hui PENG ; Zhanli REN ; Nan YU ; Dong HAN ; Tao QIN ; Yongjun JIA ; Yuxin LEI ; Yangyang YAN
Journal of Practical Radiology 2024;40(10):1712-1716
Objective To explore the effect of deep learning image reconstruction(DLIR)algorithm combined with"double low"[low voltage(kV)and low contrast agent dosage]technique on the image quality of coronary computed tomography angiography(CCTA)in overweight patients compared with adaptive statistical iterative reconstruction(ASIR-V)and filtered back projection(FBP).Methods Fifty-two patients with body mass index(BMI)between 25.1 kg/m2and 28 kg/m2 who underwent CCTA scanning were prospectively selected,all of whom scanned on a GE Revolution APEX-CT with a tube voltage of 80 kV,a smart mA(500-1 300 mA),a noise index of 30,and a contrast dosage of 0.5 mL/kg;four groups of images were reconstructed for each patient,FBP,50%ASIR-V,DLIR-M,and DLIR-H.The CT and SD values of the aorta(AO)root,the proximal segment of the right coronary artery(RCA),the left circumflex(LCX),the left anterior descending branch(LAD)and the pericardial fat were measured,and the signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)were calculated.Two doctors experienced in the diagnosis of cardiovascular disease were selected to subjectively score the reconstructed images using a double-blind method.The SD value,SNR value,CNR value and subjective scores of images in the four groups were compared.Results In the objective image quality evaluation,there were statistically significant differences in SD value,SNR value and CNR value of reconstructed images in the four groups(P<0.05).As the four groups of reconstruction algorithms FBP,50%ASIR-V,DLIR-M,and DLIR-H were changed sequentially,the image SD value gradually decreased,the SNR value and CNR value gradually increased,and the DLIR-H group had the lowest SD value and the highest SNR and CNR values.In the subjective image quality evaluation,the subjective scores of the two doctors had good consistency(Kappa value=0.900),and the difference between them was statistically significant(P<0.001).The subjective scores of DLIR-M and DLIR-H groups were higher.Conclusion DLIR algorithm combined with"double-low"technique can significantly improve the CCTA image quality of overweight patients,which is better than 50%ASIR-V and FBP.