1.ENDOMORPHIN-1 IS MORE POTENT THAN ENDOMORPHIN-2 IN INHIBITION OF SYNAPTIC TRANSMISSION IN SUBSTANTIA GELATINOSA OF ADULT RAT SPINAL CORD
Dongni LENG ; Yupeng FENG ; Yunqing LI
Chinese Journal of Neuroanatomy 2005;21(3):269-275
Effects of endomorphin-1 (EM-1) and endomorphin-2 (EM-2) on synaptic transmission were investigated on neurons in substantia gelatinosa (SG) of the spinal dorsal horn by whole-cell voltage clamp recording. Both EM-1 (1 μmol/L) and EM-2 (1 μmol/L)remarkably reduced the frequency but not the amplitude of miniature excitatory postsynaptic currents (mEPSCs) and miniature inhibitory postsynaptic currents (mIPSCs). These effects were antagonized by 3-funaltrexamine ( β-FNA, 10 μmol/L), a selective μ-opioid receptor antagonist. Noticeably, EM-1 showed higher potency in decreasing the frequency of mEPSCs and mIPSCs than that of EM-2. These results indicate that EMs suppress both excitatory and inhibitory synaptic transmission by activating presynaptic μ-opioid receptors in the SG and EM-1, compared with EM-2, might be a more potent endogenous analgesic at the spinal cord level.
2.Quality standard for Shuwei Capsules
Peiyi LI ; Mali FENG ; Yanyan NIU ; Lili JIA ; Yupeng WU ;
Chinese Traditional Patent Medicine 1992;0(12):-
AIM: To study the quality standard for Shuwei Capsule (Resina Ferulae, Rhizoma Corydalis, Radix Aucklandiae, etc.). METHODS: Radix Aucklandiae, Rhizoma Cyperi were identified by TLC, and ferulic acid was determined by HPLC. RESULTS: TLC spots developed were fairly clear, and the blank test showed no interference. Ferulic acid showed a good linear relationship in the concentration range of 0.007~0.056?g and the average recovery was up to 98.51%, RSD was 2.64%. CONCLUSION: The method is simple with strong specificity and good reproducibility, and can be used as the quality control of this preparation.
3.Comparison of one-stage resection and anastomosis of acute complete obstruction of right and left colonic carcinoma
Feng CAO ; Yajun WANG ; Fei LI ; Yu FANG ; Ang LI ; Jia LI ; Yupeng ZHANG
Chinese Journal of Current Advances in General Surgery 1999;0(03):-
Objective:To compare the short-term result of one-stage resection and anastomosis for patients with acute complete obstruction of the right and left colonic carcinoma.Methods:The clinical data of 80 patients undergoing emergency one-stage resection and anastomosis of acute complete obstruction for left and right colonic carcinoma were retrospectively analyzed.Results:Thirty-seven patients were operated on for obstructive carcinoma of the right colon,the mortality was 5.4%(2/37),the rate of complication was 21.6%(8/37),the mean hospital stay and cost was(31.6?12.8)d and(52794.9?60804.3)Yuan RMB,respectively.Forty-three patients were operated on for obstructive carcinoma of the left colon.the mortality was 2.3%(1/43),the rate of complication was 25.6%(11/43),the mean hospital stay and cost was(29.6?14.8)d and(50 192.8 ?39 727.4) Yuan RMB respectively.There was one case of anastomotic leakage in both groups.There were no significant differences of mortality and the rate of complication of the two groups.Conclusions:One-stage resection and anastomosis of acute complete obstruction of left colonic carcinoma can be performed as safely as in those with acute obstruction of right.Intraoperative decompression should be considered seriously in left colonic obstruction prior to the anastomosis following colonic resection.
4.Analyzing of the evolutionary trend of clinical features and therapy in 68 cases of infective endocarditis
Yupeng WANG ; Zhaoping LI ; Xinheng FENG ; Weihong LI ; Lijun GUO ; Wei GAO
Chinese Journal of Practical Internal Medicine 2001;0(02):-
Objective To analyze the evolutionary trend of clinical features in infective endocarditis.Methods The study enrolled 68 patients who were diagnosed as having infective endocarditis from July 1987 to July 2007.The patients were divided into two groups:group Ⅰ included patients from 1987 to 1997,group Ⅱ included patients from 1997 to 2007.All clinic data were compared.Results In both groups,61 patients(89.7%) had basic heart diseases,67 patients(98.5%) had fever and 62 patients(91.2%)had cardiac murmur;41 patients(60.3%) had positive results in the blood culture.Vegetations were found in 57 cases(83.8%) by echocardiography.The rate of surgical treatment was 19.1%,the total cure rate was 66.7%.Comparing the data between the two groups,age of onset changed from (36.7?12.7)years to (44.4?18.6)years(P
5.Content Determination of Amygdalin in the Lianhua Qingwen Capsule by HPLC
Dan BI ; Yupeng CHEN ; Shujing WANG ; Guijin WANG ; Qian ZHAO ; Feng WEI
China Pharmacy 2016;27(21):2978-2979,2980
OBJECTIVE:To establish a method for the content determination of amygdalin in Lianhua qingwen capsule. METH-ODS:HPLC was performed on the column of Phenomenex Kinetex XB-C18 with mobile phase of acetonitrile-0.2%Phosphoric acid so-lution(6∶94,V/V)at a flow rate of 1.0 ml/min,the detection wavelength was 207 nm,column temperature was 30℃,and the injec-tion volume was 10μl. RESULTS:The linear range of amygdalin was 43.16-215.80 μg/ml(r=0.999 7);the limit of detection was 0.431 6μg/ml,the limit of quantitation was 1.294 8μg/ml;RSDs of precision,stability and reproducibility tests no more than 0.69%;recovery was 95.16%-100.49%(RSD=1.67%,n=9). CONCLUSIONS:The method is simple and rapid with high accuracy and well reproducibility,and can be used for the content determination of amygdalin in Lianhua qingwen capsule.
6.Three-dimensional constructive interference in steady state sequence for displaying anterolateral ligament of knee joint
Yupeng ZHU ; Xiaoyan TANG ; Lei SUN ; Shaohua WANG ; Feng DUAN ; Chuanyu ZHANG ; Tengbo YU ; Dapeng HAO
Chinese Journal of Medical Imaging Technology 2018;34(5):765-769
Objective To observe the value of three-dimensional constructive interference in steady state (3D-CISS) sequence for displaying anterolateral ligament (ALL) of knee joint.Methods MR scans of right knee joint were performed on 30 healthy volunteers,and the protocol included axial and coronal fat saturation proton density weighted imaging (FS-PDWI) and 3D-CISS sequence.MRP and CPR (reconstructive angles including 0°,30°,60°,90°,120°,150° and 180°) images were generated from of 3D-CISS sequence.The visibility rates of the femoral part,meniscal part,tibial part,meniscal insertion,femoral footprint and tibial footprint of ALL were compared among different protocols.Results The visibility rates of tibial footprint and femoral footprint of ALL on 3D-CISS CPR images were both 96.67% (29/30),and on 3D-CISS MPR images were both 93.33% (28/30),all of them were higher than those on FS-PDWI images (all P<0.017).The visibility rates of tibial part,meniscal part and meniscal insertion of ALL on 3D-CISS CPR images were 96.67% (29/30),83.33% (25/30) and 83.33% (25/30),respectively,and all of them were higher than those on FS-PDWI images (all P<0.05).There was no statistical difference of visibility rate of femoral part between 3D-CISS CPR images and FS-PDWI images (P=0.095).Conclusion 3D-CISS sequence with CPR can significantly enhance the ability to identify ALL.
7.The antidiabetic effect of jejunal exclusion surgery for T2DM rats
Ning FENG ; Feng LIN ; Xin KANG ; Fan XUE ; Yougang CUI ; Xu ZHANG ; Yupeng YI ; Xiangyu KONG ; Wenzhi LIU
Chinese Journal of Endocrine Surgery 2018;12(3):183-187
Objective To study the curative effects of jejunal exclusion surgery for STZ-induced T2DM SD rats.Methods 60 SD rats were induced to be the T2DM SD rats by intraperitoneal injection of streptozotocini.As a result,55 T2DM SD rats were successfully acquired which were randomly divided into 3 groups,20 rats in the jejunal exclusion group (A),20 rats in the sham operation group (B) and 15 rats in the control group (C).Jejunal exclusion surgery was performed in group A,jejunojejunostomy was performed in group B,and group C were fed normally.The body weight,fasting blood glucose,fasting plasma insuhn level and GLP-1 level were measured before operation and at the 1st,2rid,4th,8th and 16th week after operation.Results As compared with that before operation and that of the control group,the body weight in group A markedly declined at the 2nd,4th,8th and 16th week (352.14±9.00,342.84±8.90,336.64±10.26,330.34±9.12,P<0.05).The fasting plasma glucose levels in group A markedly declined at the 2nd,4th,8th and 16th week (14.62±1.10,12.12±1.38,8.75± 1.06,7.55±1.00,P<0.05).The fasting plasma insulin level in group A was maikedly increased at the 2nd,4th,8th and 16th week (14.62±3.10,16.12±3.38,17.75±4.06,17.55±3.10,P<0.05).GLP-1 level in group A was markedly increased at the 1st,2nd,4th,8th and 16th week (11.02±0.85,14.42±1.18,16.02±1.59,17.62±1.02,18.12±0.71,P<0.05).Conclusions The jejunal exclusion surgery is effective in controlling blood glucose,which is an ideal and lasting method.This surgery has also showed influence on body weight.
8.Relationship between Oxygen Uptake Efficiency Slope and Left Ventricular Systolic and Diastolic Function in Elderly Patients with Coronary Heart Disease
Shunlin XU ; Yupeng WANG ; Sihua YAO ; Dan LIU ; Wei ZHAO ; Xinheng FENG ; Wei GAO
Chinese Journal of Sports Medicine 2018;37(2):115-120
Objective To investigate clinical significance and the correlation between oxygen uptake efficiency slope(OUES) measured by the cardiopulmonary exercise test(CPET) and echocardiographic left ventricular function in elderly patients with coronary heart diseases after the percutaneous coronary intervention.Methods Patients aged 65 years and over after PCI and CPET were enrolled to collect relevant parameters including the peak oxygen consumption(VO2peak),oxygen pulse(VO2/HR),OUES and cardiorespiratory fitness(CRF) index,also mitral annulus systolic peak speed(Sm),early diastolic mitral flow velocity Em and mitral annular early diastolic peak velocity Em ratio(E/Em) using the echocardiography.Patients with systolic velocity of mitral annulus(Sm)≥8 cm/s were assigned to the normal Sm group,while the rest were selected into the lower Sm group.The correlation between the cardiopulmonary fitness and cardiac function was analyzed.Results Four hundred and two patients were enrolled,with an average age of 71 ± 5 years,283 males(70.40%),and 119 females(29.60%).Among them,111 (27.61%) were 75 years of age or older,202(50.25%) ranging from 65 to 69 and 89 (22.14%) between 70 and 74.Totally 227 patients were diagnosed as angina pectoris(56.47%),62 as acute myocardial infarction (15.42%),and 113 patients with old myocardial infarction (28.11%).It was found that the heart systolic function was associated with CRF:Sm and OUES were positively correlated independently(r=29.220,P=0.001);Em was positively related to VO2peak(r=0.176,P<0.001) andOUES (r=0.151,P=0.003).However,E/Em was negatively correlated with VO2peak (r=-0.199,P<0.001),VO2/HR (r=-0.118,P=0.018) and OUES (r=-0.201,P<0.001).The left atrial pressure was negatively correlated with VO2peak (r=-0.187,P<0.001),VO2/HR (r=-0.108,P=0.030) and OUES (r=-0.185,P< 0.001).Left ventricular ejection fraction and left ventricular end diastolic diameter were not found to be related to cardiorespiratory fitness parameters (P>0.05).Conclusion The cardiopulmonary exercise test can be used as a practical method to evaluate and guide the rehabilitation exercises.The CRF parameters can evaluate the heart function exercise and is significantly correlated to the resting cardiac systolic and diastolic function parameters.
9.TiRobot combined with three-dimensional imaging to assist minimally invasive treatment of pelvic fractures
Yongbiao WANG ; Xiaoreng FENG ; Yiyi YAO ; Jinbiao LIN ; Jinfa ZHENG ; Lianxiong GUAN ; Yupeng LI ; Zhaopei LUO ; Wenya ZHAO
Chinese Journal of Orthopaedic Trauma 2022;24(10):856-861
Objective:To explore the efficacy and safety of TiRobot combined with three-dimensional imaging in the minimally invasive surgery for pelvic fractures.Methods:A retrospective analysis was conducted of the 40 patients with pelvic fracture who had been treated by fixation with S1 and S2 sacroiliac screws at Department of Orthopaedics and Traumatology, Yangjiang People's Hospital from January 2019 to May 2021. They were divided into 2 groups according to their treatment methods. In the TiRobot group of 20 cases subjected to percutaneous sacroiliac screw fixation assisted by TiRobot combined with three-dimensional imaging, there were 13 males and 7 females with an age of (38.2 ± 8.8) years. In the manual group of 20 cases subjected to fixation with manual placement of sacroiliac screws under conventional C-arm fluoroscopy, there were 11 males and 9 females with an age of (37.3 ± 9.2) years. The 2 groups were compared in terms of fluoroscopy time for screw placement, guide needle adjustment, operation time, intraoperative blood loss, visual analogue scale (VAS) 72 hours after operation, postoperative hospital stay, time to ambulation, excellent to good rate of screw placement, complication rate, fracture union time, Majeed score at 6 months after operation, and excellent to good rate of functional evaluation.Results:There was no significant difference between the 2 groups in their preoperative general data, showing they were comparable ( P > 0.05). In the TiRobot group, fluoroscopy time for screw placement [(8.2 ± 2.9) s], guide needle adjustment [(0.4 ± 0.2) times], operation time [(67.4 ± 5.5) min], and intraoperative blood loss [(36.5 ± 8.0) mL] were significantly less than those in the manual group [(40.4 ± 4.5) s, (8.6 ± 0.7) times, (78.4 ± 7.2) min, and (41.6 ± 7.8) mL], postoperative VAS [3.0 (4.0, 5.0) points] was significantly lower than that in the manual group [4.0 (5.0, 6.0) points], the excellent to good rate of screw placement (100%, 40/40) was significantly higher than that in the manual group (85.0%, 34/40), and the complication rate (5.0%,1/20) was significantly lower than that in the manual group (35.0%, 7/20) (all P < 0.05). There was no significant difference between the 2 groups in postoperative hospital stay, time to ambulation, fracture union time, Majeed score, or excellent to good rate of functional evaluation ( P > 0.05). Conclusion:In the minimally invasive surgery for pelvic fractures, TiRobot combined with three-dimensional imaging leads to positive outcomes, because it can reduce operation time and radiation exposure, improve accuracy of screw placement, and increase safety.
10.Terminal tracer equipment based on active light source array for surgical robot
Yupeng FENG ; Jie ZHANG ; Xinghai YANG
Chinese Journal of Medical Physics 2024;41(2):220-226
A non-bracket terminal tracer equipment with multi-angle active light source array is developed to reduce the effects of view obstruction on robot navigation.The multiple-angle light source array is established using a large prism and a small prism,and then the positions of the mechanical arm and the tool center point are calculated via the cooperation of binocular cameras.A simple model built with COMSOL software is used to verify the signal coverage of the tracer equipment.The experiments conducted for signal coverage and static positioning demonstrate its effectiveness and stability,suggesting that the tracer equipment can meet the task requirements of the surgical robot.