1.Analysis of alarm management and alarm information integration technology for ICU's medical device.
Yunming SHEN ; Kun ZHENG ; Sheng WU ; Lin WANG ; Long CHEN
Chinese Journal of Medical Instrumentation 2014;38(4):270-273
This paper analyzed current problems and challenges facing hospitals in alarm management both abroad and at home. Based on a survey conducted on alarm management in hospitals, plus an analysis on different kinds of data interfaces and data exchange protocols of the medical equipment used in ICUs, a solution of alarm management is put forwarded which is based on alarm information integration and processing. It aims at improving medical equipment alarm management and reducing relevant adverse events.
Automatic Data Processing
;
Clinical Alarms
;
Intensive Care Units
2.Discussion on Quality Evaluation Method of Medical Device During Life-Cycle in Operation Based on the Analytic Hierarchy Process.
Caixian ZHENG ; Kun ZHENG ; Yunming SHEN ; Yunyun WU
Chinese Journal of Medical Instrumentation 2016;40(1):13-16
The content related to the quality during life-cycle in operation of medical device includes daily use, repair volume, preventive maintenance, quality control and adverse event monitoring. In view of this, the article aims at discussion on the quality evaluation method of medical devices during their life cycle in operation based on the Analytic Hierarchy Process (AHP). The presented method is proved to be effective by evaluating patient monitors as example. The method presented in can promote and guide the device quality control work, and it can provide valuable inputs to decisions about purchase of new device.
Decision Support Techniques
;
Durable Medical Equipment
;
standards
;
Equipment Design
;
Quality Control
3.Design of a Special Shaped Foam Dressing Based on Anatomy.
Yunming SHEN ; Lin WANG ; Siyu ZHENG ; Keping ZHANG ; Kun ZHENG
Chinese Journal of Medical Instrumentation 2015;39(4):265-267
As the dressings currently used in clinic settings unflat shape in general, they can't be fitted completely on occiput, heel, elbow, knee and other body parts unflat. This paper developed one kind of foam dressing of special shape based on local anatomy. The foam dressing is waterproof and air permeable, it can cover the wound closely enough to prevent bacteria from invasion and infection. With a saturated absorption ratio of 1: 8 or higher, it can keep the wound clean and moisture by absorbing large amounts of wound inflammatory secretions and is almost completely permeable to oxygen and carbon dioxide. Assuring safety and effect meanwhile, it has better outcomes than common dressings in the same application settings.
Bandages
;
Wound Healing
4.Guiding medical equipment procurement by human factors engineering
Long CHEN ; Yunming SHEN ; Kun ZHENG ; Sheng WU
Chinese Journal of Hospital Administration 2013;(6):451-453
Human factors engineering is a promising interdisciplinary subject in applied sciences.This study presented the development and research purposes of human factors engineering.Based on case studies,the authors probed into the importance of the engineering in the design,management and procurement of medical equipments,for the purpose of optimizing medical equipment design,manufacturing and procurement.
5.Evaluation of serum CA125 and endometrial antibody for the diagnosis of endometriosis
Xiao SHI ; Bo ZHANG ; Yuxin TANG ; Yunming SUN ; Zhonghai SHEN
Chinese Journal of Rehabilitation Theory and Practice 2003;9(6):346-347
ObjectiveTo discuss the clinical value of serum CA125 and endometrial antibody (EMAb) for the diagnosis of endometriosis.Methods216 patients were determined by the presences of CA125 and EMAb before operation.ResultsAll cases were diagnosed by pathology after operation. CA125 positive rate in the endometriosis group was 58.3% and that in the control group was 12.5%. The difference between two groups was significant (P<0.01).EMAb positive rate in the endometriosis group was 31.3% and that in the control group was 14.3%. The difference between two groups was also significant (P<0.01). When determining CA125 alone to diagnose endometriosis, the sensitivity rate was 58.3% and specificity rate was 87.5%. If determining EMAb alone to diagnose endometriosis, the sensitivity rate was 31.3% and specificity rate was 85.7%. When one of them was used as diagnostic criterion, the sensitivity and specificity were 64.6% and 73.2% respectively. If combining use of both CA125 and EMAb as diagnostic criterion, the sensitivity and specificity were 25.0% and 100% respectively.Conclusions The determination of serum CA125 or EMAb levels is helpful for the qualitative diagnosis of endometriosis, especially using them combined, the diagnostic accuracy may be enhanced.
6.Investigation and study on pictogram commonly used in medical equipment.
Yunming SHEN ; Zheng KUN ; Chen LONG
Chinese Journal of Medical Instrumentation 2010;34(5):386-388
Investigated and analyzed the graphical symbols commonly used in medical equipment, their benefits and drawbacks. From the perspective of human factors engineering, some root causes of poor pictogram as well as their relations with medical equipment adverse events were addressed. Furthermore, how to deal with the problems with current pictogram aiming at reducing use error was also discussed.
Equipment Design
;
Equipment and Supplies
;
Product Labeling
7.System Integration of Infant Incubators' Quality Control Testing Based on MCU.
Long CHEN ; Kun ZHENG ; Yunming SHEN
Chinese Journal of Medical Instrumentation 2018;42(4):259-261
This study is aimed to design the testing system of multiple parameters of the incubators, and to make their quality control plans. Also it is required to establish a model of data collection and processing based on MCU, and to program the host computer software in order to analyze data. The result shows that the testing system is accurate and stable; also it is convenient to collect the data. This testing system is a good complement of the quality control of incubators. It has a high practical value in improving medical safety and reducing the occurrence of adverse events.
Incubators
;
Incubators, Infant
;
standards
;
Infant, Premature
;
Quality Control
;
Software
8.Development of a Deep Learning Algorithm for Classification of Neuroblastoma.
Long CHEN ; Kun ZHENG ; Yunming SHEN ; Chang SU
Chinese Journal of Medical Instrumentation 2019;43(4):255-258
In this paper, the classification and location of neuroblastoma in NMR images are realized by using Deep Neural Network(CNN) algorithm as the core technology. The module is integrated to realize the development of computer-aided diagnostic software. It is used to make up for the gap in the field of intelligent identification and accurate positioning of neuroblastoma in the current nuclear magnetic resonance detection technology, effectively reduce the work intensity of doctors reading films, and further promote the clinical application and technical development of nuclear magnetic resonance detection technology in the diagnosis of neuroblastoma.
Algorithms
;
Deep Learning
;
Humans
;
Magnetic Resonance Imaging
;
Neural Networks (Computer)
;
Neuroblastoma
;
diagnostic imaging
9.Hospital Networked Medical Equipment Safety Management.
Mangmang ZHANG ; Kun ZHENG ; Yunming SHEN ; Zhongkuan LIN ; Zheming LI
Chinese Journal of Medical Instrumentation 2018;42(4):303-304
With the continuous improvement and wide application of hospital information, more and more medical equipment is integrated into the hospital information systems, which brings new work contents and challenges for the traditional clinical engineers. This paper reviews and evaluates the current situation of networked medical equipment in the hospital. By applying the ISO 80001 and the MDS(Manufacturer Disclosore Statement for Medical Device Security), the paper puts forward the measures and suggestions for the security management of networked medical equipment.
Equipment Safety
;
Equipment and Supplies
;
Hospital Information Systems
;
Safety Management
10.Research on the Clinical Alarm Management Mechanism Based on Closed-loop Control Theory.
Zhongkuan LIN ; Kun ZHENG ; Yunming SHEN ; Yunyun WU
Chinese Journal of Medical Instrumentation 2018;42(3):173-175
This paper proposes a clinical alarm management system based on the theory of the closed loop control. The alarm management mechanism can be divided into the expected standard, improving execution rule, rule execution, medical devices with alarm functions, results analysis strategy and the output link. And, we make relevant application and discussion. Results showed that the mechanism can be operable and effective.
Clinical Alarms
;
Decision Support Systems, Clinical