1.Diagnosis and Treatment for 44 Cases of Posterior Fossa Hemangioblastoma
Bin LI ; Shaoyun JI ; Yunlong ZHONG
Journal of Chinese Physician 2001;0(08):-
Objective To investigate the diagnosis and treatment of posterior fossa hemangioblastoma.Methods The data of 44 cases with posterior fossa hemangioblastoma verified by surgery and pathology were analyzed retrospectively.Results Preoperative definite diagnosis cases were 41.Total tumor removal was achieved in 37 cases. Four cases died of the operation.Conclusions Posterior fossa solid hemangioblastoma are still challenging neoplasmas.For this kind of tumor,biopsy and partial removal are forbidden,and this tumor is removed after devascularity of supply blood artery.CT and MRI are major preoperatively diagnosis method for posterior fossa hemangioblastoma. The application of special microsurgical technique can improve surgical efficacy.
2.Study of Image Quality Comparison Based on the MTF Method Between Different Medical Rigid Endoscopes in an In Vitro Model.
Yunlong WANG ; Jun JI ; Changsong JIANG ; Zengyue HUANG
Journal of Biomedical Engineering 2015;32(2):357-362
This study was aimed to use the method of modulation transfer function (MTF) to compare image quality among three different Olympus medical rigid cystoscopes in an in vitro model. During the experimental processes, we firstly used three different types of cystoscopes (i. e. OLYMPUS cystourethroscopy with FOV of 12 degrees, OLYMPUS Germany A22003A and OLYMPUS A2013A) to collect raster images at different brightness with industrial camera and computer from the resolution target which is with different spatial frequency, and then we processed the collected images using MALAB software with the optical transfer function MTF to obtain the values of MTF at different brightness and different spatial frequency. We then did data mathematical statistics and compared imaging quality. The statistical data showed that all three MTF values were smaller than 1. MTF values with the spatial frequency gradually increasing would decrease approaching 0 at the same brightness. When the brightness enhanced in the same process at the same spatial frequency, MTF values showed a slowly increasing trend. The three endoscopes' MTF values were completely different. In some cases the MTF values had a large difference, and the maximum difference could reach 0.7. Conclusion can be derived from analysis of experimental data that three Olympus medical rigid cystoscopes have completely different imaging quality abilities. The No. 3 endoscope OLYMPUS A2013A has low resolution but high contrast. The No. 1 endoscope OLYMPUS cystourethroscopy with FOV of 12 degrees, on the contrary, had high resolution and lower contrast. The No. 2 endoscope OLYMPUS Germany A22003A had high contrast and high resolution, and its image quality was the best.
Diagnostic Imaging
;
instrumentation
;
Endoscopes
;
Endoscopy
;
instrumentation
;
Software
3.Stability of carbonate hydroxyapatite dosimeter material
Lei MA ; Ye LIU ; Jianbo CONG ; Yunlong JI ; Guofu DONG ; Junwang GUO ; Ke WU
Military Medical Sciences 2017;41(4):278-281
Objective To develop a promising type of radiation dosimeter based on doped hydroxyapatite,and to study the stability of dosimetric characteristics indepth.Methods The samples prepared by stereotyping techniques were stored under different temperatures,humidity and illumination conditions after 60Co γ-ray irradiation.Electron spin resonance (ESR) technique was used to quantitatively measure the radiation-induced free radical signal.Results The signal change was less than 3% when the dosimeter was preserved at 4℃ or room temperature within 3 months in the experiment.At 40℃,the signal changed by about 13%,but at room temperature with the humidity less than 36%,the signal changed less than 2%.The change rose to about 8% when humidity was 76%.However,no significant decay of signal strength occurred at relatively high temperatures and under high humidity conditions.When the samples were stored under average illumination of 1600 lux or in a light-resistant container,the signal changes were less than 3.8% or 3.4% respectively.Long-term stability inspection at room temperature suggested a signal change within 4.8%.Conclusion The dosimetric properties of the material don't change significantly below room temperature in a natural environment and exhibit good stability over long-term storage.The free radical signal is not influenced drastically by relatively strong light exposure.However,a high temperature or a highly humid environment may have some effect on the measurement process,which should be taken into consideration in further applications.
4.Choice of optimal phase for liver angiography and multi-phase scanning with multi-slice spiral CT
Hong FANG ; Yunlong SONG ; Yongmin BI ; Dong WANG ; Huiping SHI ; Wanshi ZHANG ; Hongxian ZHU ; Hua YANG ; Xudong JI ; Hongxia FAN
Chinese Journal of Radiology 2008;42(12):1303-1306
Objective To evaluate the effieaey of test bolus technique with multi-slice spiral CT (MSCT) for determining the optimal scan delay time in CT Hepatic artery (HA)-portal vein (PV) angiography and multi-phase scanning.Methods MSCT liver angiography and multi-phase scanning were performed in 187 patients divided randomly into two groups.In group A (n =59),the scan delay time was set according to the subjective experiences of operators; in group B (n=128),the scan delay time was determined by test bolus technique.Abdominal aorta and superior mesenteric,vein were selected as target blood vessels,and 50 HU was set as enhancement threshold value.20 ml contrast agent was injected intravenously and time-density curve of target blood vessels were obtained,then HA-PV scanning delay time were calculated respectively.The quality of CTA images obtained by using these 2 methods were compared and statistically analysed using Chi-square criterion.Resuits For hepatic artery phase,the images of group A are:excellent in 34(58%),good in 17(29%),and poor in 8 (13%),while those of group B are excellent in 128( 100%),good in 0(0%),and poor in 0(0%).For portal vein phase,the images of group Aare:excellent in 23(39%),good in 27(46%),and poor in 9(15%),while those of group B are excellent in 96 (75%),good in 28 (22%),and poor in 4 (3%) respectively.There was statistically significant difference between the ratios of image quality in group A and group B (X2=14.97,9.18,P < 0.05).Conclusion Accurate scan delay time was best determined by using test bolus technique,which can improve the image quality of liver angingraphy and multi-phase scanning.
5.Microdosimetric calculation of spherical cells and ellipsoidal red blood cells in an extremely low frequency electromagnetic field
Wei LU ; Hong WANG ; Hongmei ZHOU ; Zhentao SU ; Jing NING ; Changzhen WANG ; Yunlong JI ; Decheng QU ; Xiaomin ZHANG ; Jie PAN ; Ke WU ; Xiangdong XIE ; Guoshan YANG
Military Medical Sciences 2013;(11):814-817,826
Objective To calculate the electric field intensity and transmembrane voltage of spherical cells and ellipsoi -dal red blood cells ( RBC) in an extremely low frequency electromagnetic field .Through this calculation , we can provide reference to the search for interaction targets and mechanics between the extremely low frequency electromagnetic field and organisms.Methods The Finite Element Method was used in the numerical computation for the spherical cell model and the ellipsoidal RBC model .Results The electric field intensity of the two types of cells on the cellular membrane was both significantly higher than the applied electric field strength , and the values of the induced field strength and transmembrane voltage varied with the direction of the electric field periodically .Conclusion The cell shape and direction of the applied electric field are not the main determinants of the cellular membrane electric field intensity and the transmembrane voltage compared with electromagnetic parameters .The distribution of the electric field intensity and transmembrane voltage are re-lated to the direction of the applied electric field.
6.Analysis of miRNA-326's action on its target gene BCL-XL.
Mingming QIAO ; Xia GAI ; Hui YE ; Yanbo JI ; Yuan YU ; Yuanfeng CHEN ; Huichong XU ; Yunlong ZHUANG
Chinese Journal of Medical Genetics 2020;37(9):987-990
OBJECTIVE:
To analyze the action of miRNA-326 on its target gene BCL-XL and the molecular mechanism of platelet apoptosis regulated by miRNAs.
METHODS:
Dual-luciferase vectors containing respectively the wild-type and mutant 3'-untranslated region (3'UTR) fragments of the BCL-XL gene were constructed with firefly and renilla luciferases and transfected into 293T cells. Relative fluorescence intensities of the transfected cells were measured.
RESULTS:
Dual-luciferase reporter gene vectors for PsiCHECK- BCL-XL -3'UTR-WT (wild-type) and PsiCHECK- BCL-XL -3' UTR-MT (variant) were respectively constructed. Relative fluorescence intensities of the 293T cells co-transfected by miRNA-326 and PsiCHECK- BCL-XL -3'UTR-WT plasmid were significantly lower compared with the control group (co-transfected by a miRNA-326 negative sequence and PsiCHECK- BCL-XL -3' UTR-WT plasmid) ( P = 0.034). The relative fluorescence intensity was also significantly reduced in cells co-transfected by miRNA-326 and PsiCHECK- BCL-XL -3' UTR-WT plasmid compared with the mutant control group co-transfected by miRNA-326 and PsiCHECK- BCL-XL -3'UTR-MT plasmid (P = 0.022).
CONCLUSION
miRNA-326 may participate in the regulation of platelet apoptosis by acting on the 3'-UTR of the BCL-XL gene.
7.Experimental study on measurement of short pulsed and high-dose-rate X-ray by therapeutic grade ionization chamber
Dawei LI ; Yunlong JI ; Yong YUAN ; Hongmei ZHOU ; Guofu DONG ; Qi WANG ; Jing NING
Chinese Journal of Radiological Medicine and Protection 2021;41(8):626-630
Objective:To investigate the application of therapeutic grade ionization chamber to rapid measurement of short pulsed and high-dose-rate X-ray.Methods:The half-value layer of pulsed X-ray caused by an electron accelerator was measured by interpolation method and its equivalent energy was estimated. The cumulative doses from a certain amount of pulsed radiation at different distances in the same direction around the equipment were compared using the therapeutic grade ionization chamber and thermoluminescence measurement method . The relationship between the measurement result by using ionization chamber dosimeter and the distances away from source was analyzed. The cumulative doses from a certain amount of pulsed radiation at the same location at different frequencies were compared.Results:In working condition, 100 pulses of radiation were received accumulatively at 1 to 12 meters away from the outer wall of the equipment. The range of air Kerma was 0.08-9.65 mGy measured by using thermoluminescence dometers and 0.08 - 9.85 mGy using the ionization chamber dosimeters, respectively. The difference between both is within 10%. At different frequencies (1-10 Hz), there was no significant difference in X-ray air Kerma from 100 pulses measured by ionization chamber dosimeter at 2 m away from the front of the equipment ( P>0.05). Conclusions:The therapeutic grade ionization chamber dosimeter can be used for the rapid measurement of short pulsed X-ray radiation dose in the range of dose rates and pulse frequencies involved in the experimental accelerator device.
8.Diagnosis of two cases from one family with Joubert syndrome caused by novel mutations of TCTN1 gene by whole exome sequencing.
Huanhuan WANG ; Wenting JIANG ; Mengyao DAI ; Bing XIAO ; Yan XU ; Yu SUN ; Yu LIU ; Xiaomin YING ; Yunlong SUN ; Wei WEI ; Xing JI
Chinese Journal of Medical Genetics 2019;36(7):686-689
OBJECTIVE:
To explore the pathogenesis of two fetuses from one family affected with Joubert syndrome (JS).
METHODS:
Whole exome sequencing was employed to screen potential mutations in both fetuses. Suspected mutations were verified by Sanger sequencing. Impact of intronic mutations on DNA transcription was validated by cDNA analysis.
RESULTS:
Two novel TCTN1 mutations, c.342-8A>G and c.1494+1G>A, were identified in exons 2 and 12, respectively.cDNA analysis confirmed the pathogenic nature of both mutations with interference of normal splicing resulting in production of truncated proteins.
CONCLUSION
The genetic etiology of the family affected with JS has been identified.Above findings have enriched the mutation spectrum of TCTN1gene and facilitated understanding of the genotype-phenotype correlation of JS.
Abnormalities, Multiple
;
diagnosis
;
genetics
;
Cerebellum
;
abnormalities
;
Eye Abnormalities
;
diagnosis
;
genetics
;
Humans
;
Kidney Diseases, Cystic
;
diagnosis
;
genetics
;
Membrane Proteins
;
genetics
;
Mutation
;
Pedigree
;
Retina
;
abnormalities
;
Whole Exome Sequencing
9.Genotypic and phenotypic analysis of a patient with de novo partial monosomy 18p and partial trisomy 18q.
Bing XIAO ; Xing JI ; Hui YE ; Yu LIU ; Ying CAO ; Yunlong SUN ; Wei WEI ; Wenjuan QIU
Chinese Journal of Medical Genetics 2019;36(5):484-487
OBJECTIVE:
To explore the genetic cause for a patient with intellectual disability, short stature and multiple congenital anomalies, and to correlate the result with the clinical phenotype.
METHODS:
Routine karyotyping analysis was carried out on GTG-banded metaphase chromosomes. Single nucleotide polymorphism (SNP) microarray was used to detect microdeletions or microduplications in the patient. Fluorescence in situ hybridization (FISH) was used to ascertain the origin of aberrant chromosomes.
RESULTS:
The karyotype of the patient was 46,XY,der(18), while both of his parents had a normal karyotype. SNP array identified a 1.23 Mb deletion at 18p11.32-pter (chr18: 136 227-1 370 501, hg19) and a 33.76 Mb duplication at 18q21.1-qter (chr18: 44 250 359-78 013 728, hg19) in the patient. Above finding was confirmed by dual-color FISH with one color for 18p and another for 18q. The patient presented with some common features of 18p deletion and 18q duplication including intellectual disability and growth retardation, in addition with some features of 18p deletion including pectus excavatum, short stature and growth hormone (GH) deficiency. The patient showed progressive improvement of stature with GH therapy. Comparison of patients with previously reported dup(18q)+del(18p) recombinations suggested that, even for patients with similar breakpoints, their phenotypes have ranged from normal to severe and there were no consistent findings.
CONCLUSION
As aberrations involving double chromosomal segments often result in phenotypic variability, it has been difficult to correlate the genotype of our patient with his phenotype.
Abnormalities, Multiple
;
Chromosome Deletion
;
Chromosomes, Human, Pair 18
;
Genotype
;
Humans
;
In Situ Hybridization, Fluorescence
;
Karyotyping
;
Monosomy
;
Phenotype
;
Trisomy
10.Clinical characteristics and early prediction of acute respiratory distress syndrome in severe acute pancreatitis
Yangyang XIONG ; Yunlong LI ; Kai SONG ; Guorong CHEN ; Liang GONG ; Li JI ; Dong WU ; Jiaming QIAN
Chinese Journal of Pancreatology 2021;21(5):332-338
Objective:To explore the clinical characteristics and predictors of severe acute pancreatitis complicated with acute respiratory distress syndrome (SAP-ARDS).Methods:Clinical data of consecutive 313 SAP patients hospitalized from January 2000 to January 2020 in Peking Union Medical College Hospital, were retrospectively analyzed, including 258 cases with ARDS (ARDS group) and 55 cases without ARDS (non-ARDS group). According to the severity of ARDS, ARDS group were further divided into mild ARDS group (165 cases) and moderate to severe ARDS group (93 cases). Clinical symptoms, laboratory examination and imaging results, ICU admission time and clinical outcome, as well as the local and systemic complications, acute physiology and chronic health evaluation (APACHEⅡ) within 24 h after admission, bedside index for severity in acute pancreatitis (BISAP), CT severity index (CTSI), sequential organ failure assessment (SOFA) and quick sequenctial organ failure assessment(qSOFA) score were recorded. Univariate and multivariate logistic regression were performed to analyze independent risk factors of SAP complicated with moderate to severe ARDS. Receiver operating characteristics curves (ROC) was drawn to calculate area under the ROC curve (area under curve, AUC) and evaluate the performance of WBC and hsCRP in predicting SAP complicated with moderate to severe ARDS, and assess the performance of APACHEⅡ, BISAP, CTSI, SOFA and qSOFA scores in predicting SAP-ARDS endotracheal intubation.Results:The ICU length of stay and mortality rate of SAP-ARDS patients were significantly higher than those without ARDS [(8.3±11.6 day vs 5.7±7.7 day, 12.4% vs 3.6%, all P value <0.05)]. Univariate analysis showed that elevated WBC ( OR 4.52, 95% CI 1.64-12.4) and hsCRP ( OR 3.69, 95% CI 1.29-10.48) on admission were independent risk factors for moderate to severe ARDS with SAP. The AUC of WBC and hsCRP for predicting SAP with moderate to severe ARDS at admission were 0.651(95% CI 0.532-0.770) and 0.615 (95% CI 0.500-0.730), respectively. The predicted cut-off values (Cut-off values) were 17.5×10 9/L and 159 mg/L, respectively, and the sensitivity was 53.1% and 78.1%, the specificity was 78.1% and 48.4% respectively. The area under the ROC curve for APACHEⅡ, BISAP, CTSI, SOFA, and qSOFA score 24 h after admission in the early prediction of endotracheal intubation were 0.739 (95% CI 0.626-0.840), 0.705 (95% CI 0.602-0.809), 0.753 (95% CI 0.650-0.849 ), 0.737 (95% CI 0.615-0.836) and 0.663 (95% CI 0.570-0.794), and the optimum Cut-off values were 14 points, 3 points, 5 points, 7 points, 2 points, and the sensitivity and specificity for these predictors were 58.8% and 81.4%, 79.4% and 60.0%, 73.5% and 67.1%, 38.2% and 98.6%, 45.5% and 83.3%, respectively. Conclusions::Elevated blood WBC and hsCRP on admission were independent risk factors for moderate to severe ARDS in SAP. APACHEⅡ≥14, BISAP≥3, CTSI≥5, SOFA≥7, or qSOFA≥2 within the 24 h admission indictaed that the risk of SAP patients to receive endotracheal intubation was high.