1.Effect of sodium-calcium exchanger and its inhibitors on arrhythmia
Chinese Journal of Clinical Pharmacology and Therapeutics 2002;0(06):-
In cardiomyocytes,sodium-calcium exchanger(NCX) is regarded to play an important role in the regulation of intracellular Ca~(2+) concentration.During the cardiac ischemia/reperfusion or cardenolide intoxication,the inflow Ca~(2+) through NCX reverse mode induce calcium overload and arrhythmia.Recently,the benzyloxyphenyl derivatives have been developed as selective NCX inhibitors,which may have therapeutic potential as a new remedy for arrhythmias.
2.Protective Effects of Total Flavones of Herba Epimedii on Focal Cerebral Ischemia in Rats
Lei SHEN ; Ge ZHANG ; Yulin WU
Traditional Chinese Drug Research & Clinical Pharmacology 1993;0(04):-
Objective To study the protective effects of total flavones of Herba Epimedii(TFE)on focal cerebral ischemia of rats.Methods Rat model of middle cerebral artery occlusion was established.With Jinnaduo as a positive control drug,the effect of TFE on the neurological behavior of cerebral ischemia rat,the cerebral water volume,the cerebral infarction area,the cerebral biochemistry and the pathologic change of brain were evaluated.Results TFE improved rats neurological behavior,decreased the cerebral water volume,reduced cerebral infarction area,increased ATPase and SOD activity,decreased MDA content,and also improved the pathological changes of ischemic brain.Conclusion TFE have the protective effect on cerebral ischemia in rats,its mechanism may be concerned about improving energy metabolism and anti-oxidation.
3.Comparison of clinical effectiveness between transepithelial PRK and Epi-LASIK for myopia with thin cornea
Jie, HOU ; Yulin, LEI ; Xiuyun, ZHENG
Chinese Journal of Experimental Ophthalmology 2015;33(6):531-536
Background Integrated transepithelial photorefractive keratectomy (TransPRK) is a new kind of surface ablation and has a fast reepithelialization and uncorrective visual acuity (UCVA) recovery as well as slighter postoperative pain,and epipolis laser in situ keratomileusis (Epi-LASIK) has been recognized to be an effective method for myopia.But there have been few studies to evaluate the dynamic change of the corneal biomechanical properties and posterior corneal elevation after TransPRK.Objective This study was to assess and compare the effectiveness and safety between TransPRK and Epi-LASIK for myopia with thin cornea.MethodsThis study was approved by Ethic Committee of Jinan Mingshui Eye Hospital,and written informed consent was obtained from each patient.In this prospective non-randomized controlled study,93 right eyes of 93 myopic patients with the central corneal thickness 460 to 500 μm were included in Jinan Mingshui Eye Hospital from June to December 2013 under the informed consent.The eyes were divided into TransPRK group for 46 eyes and Epi-LASIK group for 47 eyes.UCVA,manifest refraction,haze,corneal biomechanical properties,posterior corneal elevation,Qvalue and corneal high order wavefront aberration were analyzed before and 1 week,1 month,3 months and 6 months after operation,respectively,and the examination results were compared between the two groups.Results There was no statistically significant difference in the eyes of postoperative UCVA and manifest refraction between the TransPRK group and the Epi-LASIK group at various time points (all at P>0.05).Six months after surgery,the percentage of eyes with UCVA of 1.0 or better was 93.9%,and 90.9% eyes exhibited the targeted refraction in ± 1.00 D in the TransPRK group.Corneal haze was most obvious 1 month after surgery in both groups,with the incidence of 32.6% (15/46) in the TransPRK group and 17.4% (8/47) in the Epi-LASIK group,but no significant difference was found in the eye numbers with haze between the two groups (x2 =2.841,P =0.092).No significant differences were seen in the corneal hysteresis(CH) values and corneal resistance factor(CRF) values between the two groups (CH:Fgroup =0.000,P =0.999;CRF:Fgroup =0.110,P =0.741),however,the postoperative CH values and CRF values were significantly declined in comparison with preoperative ones,with significant differences among various time points (CH:Ftime =103.658,P =0.000;CRF:Ftime =132.008,P =0.000),while there were no remarkable differences between any two time points in postoperation (all at P>0.05).Posterior corneal surface height shifted rearward 1 week,1 month,3 months and 6 months after surgery,showing remarkable differences in comparison with before surgery in both groups (Ftime =12.868,P =0.001),but no significant differences between the two groups (Fgroup =1.923,P=0.169).No significant differences were found in Q-value between the two groups (Fgroup =0.191,P=0.663).Root mean square (RMS) and spherical aberration values elevated in postoperation compared with preoperation,with significant differences between them(all at P<0.01),but the comparison between intergroup was insignificant (RMS:Fgroup =0.299,P =0.586;Spherical aberration:Fgroup =1.290,P =0.259).Conclusions TransPRK for myopia with thin cornea is safe and stably effective like Epi-LASIK.TransPRK affects corneal biomecbanical properties early after surgery but the effect gradually lessens over time.The posterior corneal elevation shows a tiny backward displacement,while posterior corneal asphericity has no change.
4.One case of human nasal myiasis.
Hongxia SU ; Lei LIU ; Yulin ZHAO
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2015;29(12):1138-1139
Human myiasis is caused by the parasitic maggots of flies. We report a case of nasal myiasis in a 37-year-old woman in Henan. The patient presented with nasal foreign-body sensation, nansal itching sneezing, snuffle and such allergic symptoms in nasal cavity. Based on maggots that were bowed from the right nasal cavity, a detailed endoscopic examination, sinus CT scan and identification of the maggot's species done by parapsychologists of the parasitology teaching and reseach section of the Zhengzhou University School of Medicine, the diagnosis of human nasal infestation by oestrus ovis was definited.
Adult
;
Animals
;
Diptera
;
Endoscopy
;
Female
;
Humans
;
Larva
;
Myiasis
;
diagnosis
;
Nose
;
parasitology
;
Nose Diseases
;
parasitology
5.Evaluation of the predictability of ablation depth in photorefractive procedures by Zeiss MEL80 and VISX Star S4 excimer laser
Xiuyun ZHENG ; Yulin LEI ; Sumei LIU ; Xiaoli MENG
Ophthalmology in China 1993;0(03):-
Objective To evaluate the predictability of ablated depth in photorefractive procedures by Zeiss MEL80 and VISX Star S4 excimer laser.Design Prospective,comparative case series.Participants 168 eyes of 84 people with myopia and cylinder.Main Outcome Measures Corneal thickness and ablated depth.Methods The thickness of cornea by Zeiss MEL80 and VISX Star S4 were measured by anterior segment OCT.The actuality ablated depth and calculated depth were compared.Results There were no significant differences between actuality ablated depth and calculated depth in Zeiss MEL80.And in VISX Star S4,the actuality ablated depth was more than calculated depth.Linear regression of changes in ablated depth on myopia and cylinder yielded the following formulaus:△ablated depth(VISX Star S4)= 2.324 *|myopia|+ 5.270 *|cylinder|-6.772.Conclusions Different excimer laser has different changes between actuality ablated depth and calculated depth.To guarantee the safety of LASIK,Ophthalmologists should know the characteristics of the excimer laser.
7.The research of myocardial fibers character in isolated rats heart based on 7.0 T diffusion tensor ;imaging
Qing FAN ; Yulin GUO ; Yuqing WANG ; Lei WANG ; Fabao GAO
Chinese Journal of Radiology 2016;50(5):384-387
Objective Using 7.0 T diffusion tensor imaging(DTI) to study myocardial fibers character in isolated rats heart in aspect of water molecular diffusion, myocardial mechanics and microstructure. Methods Fixed male rats heart (n=10) underwent DTI and the myocardial structures were quantitatively measured by Diffusion Toolkit and Matlab. The characteristic of myocardial fibers arrangement was observed and FA values and ADC values of myocardial fibers, myocardial fibers density and length, mean helix angle of left ventricular were calculated as well. Mean helix angle of anterior wall, ventricular septum, lateral wall and posterior wall of epicardium and endocardium were compared by using one?way ANOVA. Results The SD rats' myocardial fibers appeared in compact and inerratic distribution from epicardium to endocardium. Compared with HE staining, regular direction and arrangement in fibers were showed in myocardial fibers tracer map and tensor map in papillary muscle plane. Quantitative analysis showed that ADC value of SD rats' myocardial fibers was (9.6 ± 3.6) × 10-4 mm2/s, FA value was 0.80 ± 0.04, myocardial fibers density was (981±24) tracks/mm3 and myocardial fibers length was (6.18±1.71)mm. Mean helix angle of left ventricular epicardium to endocardium ranged from-81.37° to 0° and then gradually change to 82.83° . There were no significant differences in mean helix angle of anterior wall, ventricular septum, lateral wall and posterior wall of epicardium and endocardium, respectively (F=2.25, 0.40, P>0.05). Conclusions This study shows that DTI is an effective method to quantitatively measure the characteristics of myocardial fibers. This study provides useful information for further study of myocardial fibers in heart disease models.
9.Comparison of the effective optical zone after small incision lenticule extraction measured by corneal topography and modulation transfer function in myopia
Jie HOU ; Yulin LEI ; Feng RAO ; Jing ZHANG ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2021;39(2):126-132
Objective:To measure the effective optical zone (EOZ) after small incision lenticule extraction (SMILE) by using corneal topographic map and modulation transfer function (MTF), and to analyze the related factors affecting the EOZ.Methods:A retrospective observational case series study was performed.Sixty-two myopic patients (62 eyes) who underwent SMILE between December 2015 and July 2017 in Jinan Mingshui Eye Hospital were enrolled.The EOZ was measured by using tangential corneal curvature topographic map and MTF pre- and 6-month post-operatively.The repeatability of data was determined by intraclass correlation coefficient (ICC) and Cronbach Alpha coefficients; the agreement of data was identified by using Bland-Altman plot; the correlations between EOZ and surgical parameters were analyzed by utilizing Pearson correlation coefficient.This study protocol was approved by the Ethics Committee of Jinan Mingshui Eye Hospital(No.2015[013]). Written informed consent was obtained from each patient before surgery.Results:The ICC and Cronbach Alpha coefficients of EOZ measured by corneal topographic map were greater than 0.9, which showed high intraobserver repeatability.The Bland-Altman plots displayed relatively good agreement between the two methods.The 95% limits of agreement was -0.49 to 0.89 μm.Six months after SMILE, the EOZ measured by tangential corneal curvature gradient topographic map was (5.32±0.25)mm, which was (1.18±0.25)mm smaller than predicted optical zone, and the EOZ measured by MTF method was (5.07±0.32)mm, which was (0.20±0.35)mm smaller than corneal tomographic EOZ, and the difference was significant ( t=-4.487, P<0.01). A negative correlation was found between the EOZ and attempted refractive correction ( r=-0.364, P=0.004). The positive correlations were found between the EOZ and ΔKm or ΔQ 6 months after SMILE ( r=0.367, 0.514; both at P<0.01). Conclusions:The EOZ measured by tangential corneal curvature topographic map after SMILE is of high repeatability and is consistent with the result calculated by MTF method.The EOZ is significantly reduced after SMILE.
10.Establishment of quantitative fluorescence immunochromatographic assay detection method for heat shock protein 90α(HSP90α)
Yunlong WANG ; Na LI ; Yulin LI ; Jichuang WANG ; Lei CHENG ; Yuhong GAO
Chinese Journal of Immunology 2017;33(5):712-714,720
Objective:To establish quantitative a fluorescence immunochromatographic assay detection method for the heat shock protein 90α(HSP90α)in human serum.Methods: Indirect the technology of fluorescence microshers immunochromatographic assay was used to research fluorescent microsphere activation,ensure optimal testing time,determine linearity range,precision,recovery experiments,testing clinical samples and that sort of thing in the fluorescence immunochromatographicassay experiment.Results: In all the reaction conditions,it was determined that the optimal teaction time was 5 minutes,and in the best line range (0.39-100 ng/ml) precision quality control materials of high recovery (30 ng/ml) Intra-assay CV was 8.14%;quality control materials of low recovery (10 ng/ml) Intra-assay CV was 9.26%.With high,medium and low recovery of serum recovery was 100.56%,99.76%,94.1%,separately.Foreign kit(ELISA) for detection of 40 cancer patients clinical serum,the result showed that the correlation was 0.968 5.Conclusion: Establishing the method initially quantitative fluorescence immunochromatographic assay for the heat shock protein 90α(HSP90α)in human serum have high performance and linear,clinic accordance rate also can satisfy the demand of clinic quantitative detection,and will improve hopeful to applied to clinic after apprroved.