1.DNA POLYMORPHISM OF YERSINIA ENTEROCOLITICA
Medical Journal of Chinese People's Liberation Army 1982;0(01):-
To investigate the inherent characteristics of the pathogenic Yersinia enterocolitica. Polymerase chain reaction (PCR),analysis of DNA sequence,randomly amplified polymorphic DNA (RAPD) were used to study the pathogenic and nonpathogenic 10 strains of Yersinia enterocolitica. The Pathogenic Yersinia enterocolitica of serotyps 0∶3?0∶9 and 0∶5,27 were confirmed containing pathogenic gene of adherent invasion locus(ail) and their DNA fingerprints were much more similar,and it was also found that the serotype 0∶22 contained ail gene whose fingerprints was partly similar with the pathogenic ones in molecular structure. The pathogenic Yersinia enterocolitica strains were similar in the inherent and polymorphic. The serotype 0∶22 may have relativly evaluated association with pathogenic Yersinia enterocolitica, which is possible that it got potentially pathogenicity.
2.Research progress of biodegradable stent in the application for benign luminal stenosis
Yueqi ZHU ; Yingsheng CHENG ; Minghua LI
Journal of Interventional Radiology 2006;0(09):-
Stent implantation plays an significant role in the interventional therapy, mainly with permanent stent, possessing many disadvantages such as restenosis and inflammatory hyperplasia and can thus hardly be used in children and nonmalignant stenosis. Biodegradable stent has theoretical capability to solve these problems and acquires a bright future. Nowadays, with the development of material industry and manufacture craft, biodegradable stent technique has turned up to be mature in last decades. Through the strict animal experiments and prophase of clinic application, satisfactory result has been acquired. We believe that bioabsorbable stent will be widely used in many benign diseases which would be a good supplement for permanent stent in the near future.
3.A newly-designed temporary cardia stent for the treatment of achalasia:an experimental study in canine models
Xiaochun KUANG ; Yingsheng CHENG ; Yueqi ZHU ; Feng LI ; Weiguo WANG
Journal of Interventional Radiology 2006;0(08):-
Objective To assess the efficacy and safety of a newly-designed temporary covered cardia stent for the treatment of achalasia in canine models and to investigate the histopathological changes at different points of follow-up time after the stent was removed. Methods The canine achalasia model was created by injecting benzyl-dimethyl-tetradecyl ammonium chloride (BAC) circumferentially into the lower esophageal sphincter (LES) of the dogs. Twenty-four dogs with achalasia were randomly and equally divided into two groups with 12 dogs in each group:control group (using routine esophageal stents) and study group (using newly-designed temporary covered cardia stents). Under fluoroscopic guidance stents were implanted in the esophagus and were taken away from the esophagus 4 days after stent insertion in experimental dogs of both groups. LES pressures and timed barium esophagography (TBE) were performed in all dogs before and immediately after the stenting procedure,as well as at one week,3 and 6 months after the stent was removed. Every three dogs were sacrificed each time at one week,3 and 6 months after the stent was removed. The esophageal cardia was excised and sent for pathological examination. Results All animals well tolerated the stent insertion / removal and the follow-up procedures. No severe complications such as esophageal perforation occurred. Comparison between two groups showed that stent migration occurrence was much lower in study group (n = 1) than that in control group (n = 5). The reduction of LES pressures in study group was more significant in comparison with control group (at 6-month follow-up,P = 0.027). The difference in barium column product (height ? width) between 0-min and 5-min TBE was statistically significant in study group (at 3-month follow-up,P = 0.009). Integrated analysis of multi-comparison for LES pressures among subgroups of each group revealed that the dogs in study group exhibited better outcomes than the dogs in control group. Both proliferating cell nuclear antigen (PCNA) and ?-smooth muscle actin (?-SMA) immuno-staining revealed that the inflammatory reaction reached its peak at 1-month follow-up. Trichrome staining indicated that the collagenous fiber proliferating index inclined to be stable at 3-month follow-up. Conclusion In treating achalasia in canine models the newly-designed temporary covered cardia stent is superior to the routine esophageal stent in respect of safety and efficacy.
4.Application of batroxobin plus aspirin in preventing post-intervention re-stenosis in patients with diabetic lower-limb ischemia:analysis of therapeutic effects
Jing LI ; Jue WANG ; Yueqi ZHU ; Peilei ZHANG
Journal of Interventional Radiology 2014;23(10):865-869
Objective To assess the clinical value of batroxobin plus aspirin therapy in reducing the incidence of arterial re-stenosis or re-occlusion in diabetic patients with lower-limb ischemia after receiving angioplasty. Methods A total of 110 diabetic patients with symptomatic arterial obstructions were randomly divided into study group (n=50) and control group (n=60). Aspirin 100 mg/d plus batroxobin 5 IU every other day for six times was used in patients of the study group, while only aspirin 100 mg/d was used in patients of the control group. The follow-up finishing point was the end of 12 months. The arterial re-stenosis or re-occlusion was evaluated with magnetic resonance angiography (MRA) and/or vascular sonography. Amputation above the ankle, death, and the cumulative rate of amputation or death were determined, and the limb salvage and survival rates were assessed by using Kaplan-Meier analysis method. Results Twelve months after the treatment, the occurrence of restenosis in the study group and the control groups was 42.8%and 28.9% respectively (P = 0.002). MR angiography and color- duplex sonography revealed that the restenosis occurrence was much higher in infrapopliteal artery (P = 0.003) and in longer (length > 10 cm) diseased artery (P = 0.001). Twelve months after angioplasty Kaplan-Meier analysis showed that the limb salvage-survival rates of the study group and the control group were 78.2%and 93.5%respectively (log-rank test, P = 0.032 4). Conclusion Combination use of batroxobin and aspirin can effectively reduce the occurrence of restenosis after arterial angioplasty, and the clinical effect is particularly better for the artery distal to the knee and the artery with longer lesion (length > 10 cm), besides this treatment can also improve limb salvage rate.
5.The establishment of aneurysm model at the carotid artery bifurcation in experimental dogs
Jue WANG ; Yuwu ZHAO ; Yueqi ZHU ; Jing LI
Journal of Interventional Radiology 2015;(3):231-235
Objective To investigate the feasibility of establishing aneurysm model at the carotid artery bifurcation in experimental dogs. Methods New aneurysm model at the common carotid artery (CCA) bifurcation was established in 18 experimental dogs, which were randomly and equally divided into study group (n =9) and control group (n=9). In the dogs of the study group, the bifurcation top was treated with elastase, while in the dogs of the control group the bifurcation top was treated with saline. Angiography was separately performed immediately after, and at 12 and 24 weeks after the operation to observe the changes of the aneurysm top. Pathological examination was separately carried out at 12 and 24 weeks after the operation. Results Angiography showed that nascent aneurysm formation (mean diameter of 3.2 ± 0.4 mm) was demonstrated at the arterial bifurcation top in 5 dogs of the study group; while no nascent aneurysm at the arterial bifurcation top was observed in the control group. During the follow-up period, no rupture of the nascent aneurysm occurred in the study group. Pathological examination revealed that discontinued internal elastic membrane, elastic fiber fracture, thinning muscle layer and reduction of smooth muscle cells were detected in the aneurysm at bifurcation top in the study group; when compared with those in the control group, the difference was statistically significant (P< 0.001). Conclusion The elastase-induced digestive degeneration of artery wall can cause new aneurysm formation in the newly-established aneurysm located at carotid artery bifurcation in experimental dogs.
6.Analysis of factors related to breastfeeding of premature infants discharged from neonatal intensive care unit
Mingdi SUN ; Xiaoxu REN ; Na LI ; Yueqi WANG
Chinese Journal of Practical Nursing 2021;37(8):613-618
Objective:To retrospectively analyze the influencing factors during the hospitalization of premature infants in the neonatal intensive careunit (NICU) based on the breast-feeding choices of the primary family caregivers of premature infants discharged from NICU.Methods:According to the breast-feeding status of 342 premature infants discharged from the NICU from The First hospital of Jilin University from June 1st, 2019 to December 31th, 2019, a self-designed data collection form for premature infants was used to investigate them, and the influencing factors of NICU hospitalization on breast-feeding selection were retrospectively analyzed.Results:The factors influencing breastfeeding included gestational age ( tvalue was-2.177, P=0.029), birth weight ( tvalue was-2.036, P=0.043), feeding mode during hospital stay ( χ2value was 6.582, P=0.010), length of hospital stay ( Zvalue was-2.205, P=0.027), maternal age ( Zvalue was-2.975, P=0.003), maternal education level ( χ2value was 8.350, P=0.04) and twin pregnancy ( χ2value was 7.367, P=0.007). The results of multivariate Logistic regression analysis showed that breast-feeding during hospitalization ( P=0.003) and older age of the mother ( P<0.001) were favorable factors to promote breast-feeding. Twin pregnancy ( P=0.006), low maternal education ( P=0.001) and gestational age ( P=0.006) were the risk factors that were not conducive to the implementation of breastfeeding. Conclusion:During the hospital period, the implementation of breastfeeding and the old age of the mother are conducive to the choice of breastfeeding after discharge, while twin pregnancy, low education of the mother and premature infants of large gestational age are not conducive to the implementation of breastfeeding.
7.Exploration and practice of benefit evaluation for medical equipments based on objectives and key results
Yueqi YANG ; Xin LI ; Hong GAO ; Ying QIAN ; Xudong WANG
Chinese Journal of Hospital Administration 2021;37(1):39-42
The study aims to improve the level of fine management of medical equipments, give full play to the functions and roles for better patient service, and explore methods for evaluating the benefits of medical equipment that can take into account and reflect the needs of multiple parties. Based on objectives and key results(OKR) methods and concepts, a benefit evaluation system was developed with the goal of giving full play to the functions and roles of medical equipments, with corresponding evaluation indexes and supervision and evaluation mechanisms formulated as well. This index system could take into account the needs and concerns of hospitals, the departments in use, the management authorities and patients at large, while contributing to process supervision and continuous improvement. In the OKR practice of large medical equipments(CT, MR) from 2018 to 2019, they had performed significantly better in inspections, inspection positive coincident rates, clinical service capabilities, maintenance assurance levels, patient satisfaction, scientific research and academics among others. The use of a medical equipment benefit evaluation system based on OKR concepts and methods can provide effective evaluation indicators for the operation and management of medical equipments. In addition, the system can maintain internal improvement momentum leveraging process supervision and continuous improvement methods, in order to assure the elevation of fine management level of medical equipments of modern hospitals, thus offering better medical services for patients at large.
8.A new experimental carotid siphon aneurysm model in canine based on the MR angiography and rapid prototyping technology
Jian XIE ; Minghua LI ; Huaqiao TAN ; Yueqi ZHU ; Chunhua FAN ; Dingjun HU ; Ruihua QIAO
Chinese Journal of Radiology 2009;43(1):78-81
Objective The aim of the experiment is to make an intracranial aneurysm model in canine.Methods A digital tube was made based on raw magnetic resonance images of the human intracraaial carotid artery.Then 6 tubes were made in the 3 D rapid prototyping machine and coated with silicone.Finally we isolated the common carotid arteries of 6 canines and made them go through the tubes and anastomosed them end-to-side to get the aneurysm model.Six stents were implanted after one week.Results Six aneurysm models were successfully made in canines.The parent artery had similar geometrv of the human carotid siphon.All the aneurysms and parent arteries were patent in one week's follow-up.One canine died of excessive anesthesia after stentingr Two vaseular models kept patent in one month without stenosis.The other 3 had some stenosis on the bends of the vessel.Conclusions The aneurysm model in tIle experiment has high flexibility and reliability.The model provides an effective tool for research and testing neurovascular devices.It's also a useful device to train the neuroradiologists and interventional physicians.
9.Treatment of carotid-siphon aneurysms by using Willis stent-graft: an angiographic and histopathologic study in dogs
Yueqi ZHU ; Minghua LI ; Jian XIE ; Huaqiao TAN ; Yingsheng CHENG ; Jianbo WANG
Journal of Interventional Radiology 2010;19(4):302-308
Objective To establish a carotid siphon aneurysm model in dogs in order to test the mechanical features of a newly-designed Willis covered stent-graft and to investigate the histological reaction of the stent-implanted vessel during a follow-up period of 12 months.Methods Twenty-four saccular sidewall aneurysms were surgically created in twelve dogs(group A)and 12 carotid siphon aneurysms in another twelve dogs(group B).A Willis stent-graft was implanted in each aneurysm.Angiography was performed immediately after the procedure and 1,3,6 and 12 months after the implantation to investigate the aneurysm isolation,endoleak,stent angulation,and the patency or restenosis of the parent artery.Light and scanning electronic microscopy were used to identify aneurysmai sac thrombi,intima hyperplasia and endothelial progress of the stent-loaded arterial segment.Results In group B,postoperative immediate angiography demonstrated that two aneurysms had mild endoleak and three stents became angulated.Follow-up exam 12 months after the procedure revealed that all previous endoleaks disappeared,one parent artery became occluded and three parent arteries developed mild stenosis(<50%).In group A.occlusion of parent artery was seen in one and mild stenosis(<50%)in 2 cases.Electronic microscopy revealed new intima formation in all stents,and all aneurysmal sacs were filled with thrombi.In group B.the endothelialization process was not completed until 12 months after the stent implantation,and a marked correlation existed between endothelial cell arrangement and the hemodynamic orientation.Conclusion It is feasible to treat carotid-siphon aneurysm in dog with a Willis stent-graft.The complete endothelialization of the covered stent in tortuous vessel takes longer time than that in rather straight vessel.
10.Application of Willis covered stent in the treatment of aneurysms located in the cisternal segment of the internal carotid artery: a pilot comparative study with long-term follow-up results
Yueqi ZHU ; Minghua LI ; Chun FANG ; Wu WANG ; Peilei ZHANG ; Yingsheng CHENG ; Huaqiao TAN ; Jianbo WANG
Journal of Interventional Radiology 2010;19(4):275-280
Objective Complicated aneurysms located in the cisternal segment of the internal carotid artery(ICA-CSA)present unique therapeutic difficulties.This study is to discuss the feasibility of the Willis stent-graft in treating complicated ICA-CSA by comparing its effect with that of coiling therapy.Methods Willis covered stents were employed in 19 complicated ICA-CSAs(group A),while coils were used in 17 complicated ICA-CSAs(group B).Follow-up angiography was performed to investigate aneurysm recurrence,endoleak and parent artery(PA)stenosis.Kaplan-Meier curves were constructed to compare the recurrencefree and PA stenosis-free rate in both groups.Results Total exclusion was immediately achieved in 13 ICACSAs and minor endoleaks presented in 5 cases in group A.Total or near-total occlusion was achieved in 7 ICA-CSAs.subtotal occlusion in 8 and partial occlusion in 2 cases in group B after coiling.Acute thrombosis occurred in 1 patient in either group and re-hemorrhage happened in 1 patient after coiling.Follow-up angiography in group A revealed that 16 ICA-CSAs were completely isolated,with two parent arteries showing mild in-stent stenosis.Eighteen months after the procedure,Kaplan-Meier analysis showed that the recurrence-free rate was 93.3%and 50%,while the stenosis-free rate of parent artery was 87.5%and 100% in group A and in Group B,respectively.In group A and group B the clinical neurological symptoms were fully recovered in 9 and 9,obviously improved in 3 and 5,unchanged in 2 and 2,and aggravated in one and 0 patients,respectively.Conclusion The implantation of Willis stent-graft is a feasible endovascular therapy for complicated ICA-CSAs.When the parent artery is very tortuous or when the risk that a main collateral branch may be wrongly covered and occluded is present,the implantation of Willis covered stent can not be taken as the treatment of first choice.