1.A comparative study of biodegradable and metallic fixation for the treatment of ankle fractures among 45 cases
Xin HAN ; Jinghua WAN ; Yuantian SANG
Chinese Journal of Tissue Engineering Research 2007;0(09):-
To compare the merit and shortcoming of treatment and securities with absorbable implants and metallic fixation for fractures of the ankle,45 patients with ankle fractures were enrolled from the the Fifth Hospital of Dalian between February 2000 and May 2004 and treated with absorbable implants(n =21)and metallic fixation(n =24),respectively.All patients were available for an average duration of follow-up of 10-18 months.The results were evaluated by radiographic representations and joint function and showed that all the patients were healed in ankle fractures.The total rate of good and excellent results was 92%(19/21)in absorbable implants group and 92%(22/24)in metallic group.There were no statistic differences between these two methods.Absorbable implants is believed to be a good method for the treatment of ankle fracture instead of metallic implants.
2.Feasibility analysis of digital method for measuring supracrestal tissue height crest around implant.
Luxin LI ; Honghong LIU ; Jia CHEN ; Zhihong ZHANG ; Xiao SANG ; Lili ZHANG ; Yuantian WANG
West China Journal of Stomatology 2023;41(4):426-433
OBJECTIVES:
This study aimed to investigate the feasibility of measuring the soft tissue height of bone cristae around implant by digital method.
METHODS:
A total of 36 patients with dental implants were selected from the Dental Medicine Center of the First Affiliated Hospital of University of Science and Technology of China (Anhui Provincial Hospital) from August 2022 to December 2022. A total of 43 dental implants were enrolled. All postoperative cone beam CT (CBCT) imaging data and intraoral digital impressions obtained before surgery were immediately obtained by the patients on the day of completion of oral implant surgery and they were imported into oral implant surgery planning software for image fitting. Then, virtual implants of the same specification were placed in the planting area, and the implant position was adjusted to overlap with the implant shadow in the CBCT image. Supracrestal tissue height (STH) was measured at the implant view interface (digital group). During the operation, implant holes were prepared step by step in accordance with the standard preparation method, and implants were implanted. The upper edge of the implant was flushed with the crest of the alveolar ridge. STH was measured by perio-dontal probing (periodontal probe group). Paired t-test was used to compare the STH differences between the digital and periodontal probe groups. Bland-Altman test was used to analyze the consistency of the two methods. Intra-group correlation coefficient (ICC) was used to verify the reliability of the results measured by different surveyors using di-gital methods.
RESULTS:
No statistical significance was observed in the STH difference between the two methods (P>0.05). Bland-Altman test showed good consistency between the two methods, but the measurement of mandibular posterior teeth showed that the results of periodontal probe were greater than those of digital method. The ICC and 95%CI of the STH results measured digitally by different surveyors are 0.992 (0.986-0.996).
CONCLUSIONS
The digital me-thod is in good agreement with the periodontal probe method in measuring the soft tissue height of the bone cristae around the implant.
Humans
;
Alveolar Process/diagnostic imaging*
;
Cone-Beam Computed Tomography/methods*
;
Dental Implants
;
Feasibility Studies
;
Reproducibility of Results
;
Tooth/diagnostic imaging*