1.An Investigation on Evaluation Structure of the Patient for Ingestion Instruction in Community Pharmacies
Susumu Sashima ; Hidehiko Sakurai ; Takuya Wagatsuma ; Yousuke Sato ; Yukitoshi Hayase
Japanese Journal of Drug Informatics 2015;17(3):118-124
Objective: Many studies on patient satisfaction are conducted in community pharmacies. In contrast, the present study assess the community pharmacy function and to the best of our knowledge, appears to be the first to evaluate the professional functions of pharmacists.
Methods: In September 2010, in 1 week, we conducted a survey that focused on pharmacists’ professional abilities. I subjected the responses to factor analysis and covariance structure analysis.
Results: We obtained 2,506 effective responses (appropriately completed and returned questionnaires) of the 4,633 questionnaires originally distributed. Data of seven dimensions were obtained for factor analysis. In all, the various information provision services rendered by a pharmacist were not significant. According to the covariance structure analysis, “safety” (a pharmaceutical management item) and “responsiveness” (a complimentary element) were significant factors. Differences in the degree of influence were confirmed for each parameter in the analysis, depending on the parameter. In addition, the information provision services were significant during the acute period.
Conclusion: Because the information provision services were not significant, the influence of “asymmetric information” warrant further analysis according to the specialty. I believe that it is necessary to examine asymmetric information in greater detail in the future. In addition, I think that an interventional study that is based on these results is also necessary.
2.Empirical Study on Influencing Factors for Evaluation of Medical Service and Intention to Revisit of Patient Perspective in Community Pharmacies
Susumu Sashima ; Hidehiko Sakurai ; Yousuke Sato ; Takuya Wagatsuma ; Yukitoshi Hayase
Japanese Journal of Drug Informatics 2017;18(4):251-260
Objective: As a “family pharmacy and pharmacist,” high-quality medical service is demanded. Many patient satisfaction investigations are performed to evaluate community pharmacies, but it has been impossible until now to do so using an improvement index of the medical quality. Therefore, I investigated the influence and evaluation structure of two evaluation concepts regarding quality of medical service and patient satisfaction and intention to use again, which becomes the important key as a “family” pharmacy.
Methods: I used anonymous patient survey data gathered for the purpose of duties improvement in July 2009. I subjected the responses to factor and covariance structure analyses.
Results: Dates for four dimensions were obtained for factor analysis. As a whole, covariance structure analysis showed that, in terms of privacy and only for service quality, entertainment primarily influenced satisfaction. The ingestion instruction had a big effect on both sides. General satisfaction was also substantially influenced by service quality. The difference in influence degree was confirmed at each parameter.
Conclusion: It was found that not only satisfaction but also quality of service were equally demanded in community pharmacies. It is necessary to increase these because most are influenced by ingestion instruction as a factor in service quality. However, future investigation is necessary to clarify the detailed ingestion instruction contents.
3.Successful Endosonography-Guided Drainage of an Intra-Abdominal Abscess in a 1-Year-Old Infant.
Yukiko ITO ; Hiroyuki ISAYAMA ; Yousuke NAKAI ; Gyoutane UMEFUNE ; Tatsuya SATO ; Saori NAKAHARA ; Junko SUWA ; Keiichi KATO ; Ryo NAKATA
Gut and Liver 2016;10(3):483-485
Endoscopic ultrasound (EUS)-guided intervention has been established as a safe, effective and minimally invasive procedure for various diseases in adults, but there have been limited reports in pediatric patients. Herein, we report our experience with successful EUS-guided drainage of an intra-abdominal abscess in a 1-year-old infant concomitant with disseminated intravascular coagulation. The abscess was punctured via the stomach using a standard, convex-type echoendoscope, and the patient's condition improved after naso-cystic catheter placement. Although the clinical course was complicated by delayed hemorrhage from the puncture site, the bleeding was successfully managed by endoscopic hemostasis using a standard forward-viewing endoscope.
Abdominal Abscess*
;
Abscess
;
Adult
;
Catheters
;
Disseminated Intravascular Coagulation
;
Drainage*
;
Endoscopes
;
Hemorrhage
;
Hemostasis, Endoscopic
;
Humans
;
Infant*
;
Punctures
;
Stomach
;
Ultrasonography
4.A Meta-Analysis of Slow Pull versus Suction for Endoscopic Ultrasound-Guided Tissue Acquisition
Yousuke NAKAI ; Tsuyoshi HAMADA ; Ryunosuke HAKUTA ; Tatsuya SATO ; Kazunaga ISHIGAKI ; Kei SAITO ; Tomotaka SAITO ; Naminatsu TAKAHARA ; Suguru MIZUNO ; Hirofumi KOGURE ; Kazuhiko KOIKE
Gut and Liver 2021;15(4):625-633
Background/Aims:
Endoscopic ultrasound (EUS)-guided tissue acquisition is widely utilized as a diagnostic modality for intra-abdominal masses, but there remains debate regarding which suction technique, slow pull (SP) or conventional suction (CS), is better. A meta-analysis of reported studies was conducted to compare the diagnostic yields of SP and CS during EUS-guided tissue acquisition.
Methods:
We conducted a systematic electronic search using MEDLINE/PubMed, Web of Science, and the Cochrane Central Register of Controlled Trials to identify clinical studies comparing SP and CS. We meta-analyzed accuracy, sensitivity, blood contamination and cellularity using the random-effects model.
Results:
A total of 17 studies (seven randomized controlled trials, four prospective studies, and six retrospective studies) with 1,616 cases were included in the analysis. Compared to CS, there was a trend toward better accuracy (odds ratio [OR], 1.48; 95% confidence interval [CI], 0.97 to 2.27; p=0.07) and sensitivity (OR, 1.67; 95% CI, 0.95 to 2.93; p=0.08) with SP and a significantly lower rate of blood contamination (OR, 0.48; 95% CI, 0.33 to 0.69; p<0.01). However, there was no significant difference in cellularity between SP and CS, with an OR of 1.28 (95% CI, 0.68 to 2.40; p=0.45). When the use of a 25-gauge needle was analyzed, the accuracy and sensitivity of SP were significantly better than those of CS, with ORs of 4.81 (95% CI, 1.99 to 11.62; p<0.01) and 4.69 (95% CI, 1.93 to 11.40; p<0.01), respectively.
Conclusions
Compared to CS, SP appears to provide better accuracy and sensitivity in EUSguided tissue acquisition, especially when a 25-gauge needle is used.
5.A Meta-Analysis of Slow Pull versus Suction for Endoscopic Ultrasound-Guided Tissue Acquisition
Yousuke NAKAI ; Tsuyoshi HAMADA ; Ryunosuke HAKUTA ; Tatsuya SATO ; Kazunaga ISHIGAKI ; Kei SAITO ; Tomotaka SAITO ; Naminatsu TAKAHARA ; Suguru MIZUNO ; Hirofumi KOGURE ; Kazuhiko KOIKE
Gut and Liver 2021;15(4):625-633
Background/Aims:
Endoscopic ultrasound (EUS)-guided tissue acquisition is widely utilized as a diagnostic modality for intra-abdominal masses, but there remains debate regarding which suction technique, slow pull (SP) or conventional suction (CS), is better. A meta-analysis of reported studies was conducted to compare the diagnostic yields of SP and CS during EUS-guided tissue acquisition.
Methods:
We conducted a systematic electronic search using MEDLINE/PubMed, Web of Science, and the Cochrane Central Register of Controlled Trials to identify clinical studies comparing SP and CS. We meta-analyzed accuracy, sensitivity, blood contamination and cellularity using the random-effects model.
Results:
A total of 17 studies (seven randomized controlled trials, four prospective studies, and six retrospective studies) with 1,616 cases were included in the analysis. Compared to CS, there was a trend toward better accuracy (odds ratio [OR], 1.48; 95% confidence interval [CI], 0.97 to 2.27; p=0.07) and sensitivity (OR, 1.67; 95% CI, 0.95 to 2.93; p=0.08) with SP and a significantly lower rate of blood contamination (OR, 0.48; 95% CI, 0.33 to 0.69; p<0.01). However, there was no significant difference in cellularity between SP and CS, with an OR of 1.28 (95% CI, 0.68 to 2.40; p=0.45). When the use of a 25-gauge needle was analyzed, the accuracy and sensitivity of SP were significantly better than those of CS, with ORs of 4.81 (95% CI, 1.99 to 11.62; p<0.01) and 4.69 (95% CI, 1.93 to 11.40; p<0.01), respectively.
Conclusions
Compared to CS, SP appears to provide better accuracy and sensitivity in EUSguided tissue acquisition, especially when a 25-gauge needle is used.
6.Management of Difficult Bile Duct Stones by Large Balloon, Cholangioscopy, Enteroscopy and Endosonography
Yousuke NAKAI ; Tatsuya SATO ; Ryunosuke HAKUTA ; Kazunaga ISHIGAKI ; Kei SAITO ; Tomotaka SAITO ; Naminatsu TAKAHARA ; Tsuyoshi HAMADA ; Suguru MIZUNO ; Hirofumi KOGURE ; Minoru TADA ; Hiroyuki ISAYAMA ; Kazuhiko KOIKE
Gut and Liver 2020;14(3):297-305
Endoscopic management of bile duct stones is now the standard of care, but challenges remain with difficult bile duct stones. There are some known factors associated with technically difficult bile duct stones, such as large size and surgically altered anatomy. Endoscopic mechanical lithotripsy is now the standard technique used to remove large bile duct stones, but the efficacy of endoscopic papillary large balloon dilatation (EPLBD) and cholangioscopy with intraductal lithotripsy has been increasingly reported. In patients with surgically altered anatomy, biliary access before stone removal can be technically difficult. Endotherapy using two new endoscopes is now utilized in clinical practice: enteroscopy-assisted endoscopic retrograde cholangiopancreatography and endoscopic ultrasound-guided antegrade treatment. These new approaches can be combined with EPLBD and/or cholangioscopy to remove large bile duct stones from patients with surgically altered anatomy. Since various endoscopic procedures are now available, endoscopists should learn the indications, advantages and disadvantages of each technique for better management of bile duct stones.
7.Microvascular density under magnifying narrow-band imaging endoscopy in colorectal epithelial neoplasms
Takahiro GONAI ; Keisuke KAWASAKI ; Shotaro NAKAMURA ; Shunichi YANAI ; Risaburo AKASAKA ; Kunihiko SATO ; Yousuke TOYA ; Kensuke ASAKURA ; Jun URUSHIKUBO ; Yasuko FUJITA ; Makoto EIZUKA ; Noriyuki UESUGI ; Tamotsu SUGAI ; Takayuki MATSUMOTO
Intestinal Research 2020;18(1):107-114
Background/Aims:
Magnifying endoscopic classification systems, such as the Japan narrow-band imaging (NBI) Expert Team (JNET) classification, have been widely used for predicting the histologic diagnosis and invasion depth of colorectal epithelial tumors. However, disagreement exists among observers regarding magnifying endoscopic diagnosis, because these classification systems are subjective. We herein investigated the utility of endoscopic microvascular density (eMVD) calculated from magnifying NBI endoscopic images in colorectal tumors.
Methods:
We reviewed magnifying NBI endoscopic images from 169 colorectal epithelial tumors (97 adenomas, 72 carcinomas/high-grade dysplasias) resected endoscopically or surgically. The eMVD on magnifying NBI endoscopic images was evaluated using image-editing software, and relationships between eMVD and clinical, endoscopic, and pathological findings were retrospectively analyzed.
Results:
The eMVD in carcinomas (0.152 ± 0.079) was significantly higher than that in adenomas (0.119 ± 0.059, P< 0.05). The best cutoff value for distinguishing carcinoma from adenoma was 0.133. Sensitivity, specificity, and accuracy were 56.9%, 67.0%, and 62.7%, respectively. In addition, JNET type 2B tumors showed significantly higher eMVD (0.162 ± 0.079) compared to type 2A tumors (0.111 ± 0.050, P< 0.05).
Conclusions
The eMVD as determined by magnifying NBI endoscopy is considered to be a possible objective indicator for differentiating colorectal carcinomas from adenomas.
8.Endoscopic Ultrasound-Guided Tissue Acquisition by 22-Gauge Franseen and Standard Needles for Solid Pancreatic Lesions
Kazunaga ISHIGAKI ; Yousuke NAKAI ; Hiroki OYAMA ; Sachiko KANAI ; Tatsunori SUZUKI ; Tomoka NAKAMURA ; Tatsuya SATO ; Ryunosuke HAKUTA ; Kei SAITO ; Tomotaka SAITO ; Naminatsu TAKAHARA ; Tsuyoshi HAMADA ; Suguru MIZUNO ; Hirofumi KOGURE ; Minoru TADA ; Hiroyuki ISAYAMA ; Kazuhiko KOIKE
Gut and Liver 2020;14(6):817-825
Background/Aims:
Recently, a three-plane symmetric nee-dle with Franseen geometry was developed for endoscopic ultrasound-guided fine needle biopsy (EUS-FNB). In this ret-rospective study, tissue acquisition per pass was compared between 22-gauge Franseen FNB and standard fine needle aspiration (FNA) needles in patients with solid pancreatic le-sions.
Methods:
Consecutive patients who underwent EUSFNA or EUS-FNB for solid pancreatic lesions between Octo-ber 2014 and March 2018 were retrospectively studied. The tissue acquisition rate and the diagnostic performance per session, per pass, and at first pass were compared.
Results:
A total of 663 passes (300 by the FNB needle and 363 by the standard FNA needle) were performed in 154 patients (71 FNB and 83 FNA). The tissue acquisition rate per session and at first pass in the FNB and FNA groups was 100% and 95% (p=0.13) and 87% and 69% (p=0.007), respectively. The multivariate analysis revealed that among the patients, EUS-FNB (odds ratio, 3.07; p=0.01) was associated with a higher first-pass tissue acquisition rate. While the tissue ac-quisition rate reached a plateau after the 4th pass with FNA, it reached a plateau after the 2nd pass with FNB. Among the 129 malignant cases, the histological tissue acquisition rate per session was similar (100% and 94%), but the sensitivity by histology alone per session was higher for FNB than for FNA (93% and 73%, p<0.01).
Conclusions
The results of our retrospective analysis indicated that compared with a standard FNA needle, a 22-gauge Franseen FNB needle was associated with a higher first-pass tissue acquisition rate.