1.Sodium hyaluronate in the treatment of interstitial cystitis
Peng DU ; Yongzhong QIAO ; Xuhui ZHU ; Tao LI ; Peng ZHANG ; Yong YANG
Chinese Journal of Urology 2009;30(9):599-601
adder irritation after intra-vesical sodium hyaluronate therapy. Conclusion Intravesical sodium hyaluronate therapy can effec-tively relieve clinical symptom of IC and improve IC patients' quality of life and is well tolerated.
2.Risk factors of drug resistance in diabetes mellitus complicated by pulmonary tuberculosis
Chunwei CHAI ; Liang SHI ; Yongzhong BAI ; Liming DONG ; Rong QIAO ; Jing ZHANG ; Huiping DUAN
Chinese Journal of Primary Medicine and Pharmacy 2023;30(7):979-982
Objective:To investigate the risk factors of diabetes mellitus complicated by pulmonary tuberculosis.Methods:The clinical data of 83 patients with diabetes mellitus complicated by pulmonary tuberculosis who received treatment in Taiyuan Fourth People's Hospital from March 2020 to March 2022 were collected. These patients were divided into sensitive group ( n = 45) and resistant group ( n = 38 ) according to the results of drug sensitivity test. Univariate and multivariate non-conditional logistic regression was performed to analyze the influential factors of drug resistance. Results:Univariate logistic regression results revealed that there were significant differences in blood CD4 +T lymphocyte count ( χ2 = 11.73, P = 0.001) and diabetic complications ( χ2 = 4.94, P = 0.026). Multivariate non-conditional logistic regression analysis was performed taking whether blood CD4 +T lymphocyte count was lower than the average level and whether patients with diabetes mellitus had complications as independent variables, and taking whether drug resistance was a dependent variable. The results showed that the OR (95% CI) value of the decreased blood CD4 +T lymphocyte count was 4.909 (1.926-12.514). It is a risk factor for drug resistance of diabetes mellitus complicated by pulmonary tuberculosis. Conclusion:The decrease of blood CD4 +T lymphocyte count is a risk factor of drug resistance in diabetes mellitus complicated by pulmonary tuberculosis, and it should be intervened early in the clinic.
3.Investigation and evaluation of annual effective doses to radiation workers caused by indoor radon concentrations in underground workplaces of medical institutions
Guozhen ZHU ; Meinan YAO ; Jiayi MA ; Yongzhong MA ; Qiao MA
Chinese Journal of Radiological Health 2025;34(4):489-493
Objective To investigate the annual effective doses to radiation workers caused by radon concentrations in the underground workplaces of medical institutions, and to provide a scientific basis for the prevention and control of indoor radon in underground places. Methods A typical sampling method was used to select 5-30 medical institutions in each of Hunan, Jiangxi, Guizhou, Hubei, and Sichuan provinces. A total of 66 monitoring points in 66 medical institutions were selected. The indoor radon concentrations in underground workplaces were measured cumulatively using CR-39 solid nuclear track detectors. The radiation dose to radiation workers was estimated according to the method outlined in the Requirements for control of indoor radon and its progeny (GB/T 16146—2015). The Kruskal-Wallis H test was used to compare the differences in indoor radon concentrations between different provinces. Results The average indoor radon concentration in the underground workplaces of 66 medical institutions was 69.8 Bq/m3, with the highest being 147.6 Bq/m3. The average indoor radon concentrations in the underground workplaces of medical institutions in Sichuan, Guizhou, Hubei, Jiangxi, and Hunan were 72.1, 83.2, 66.6, 88.4, and 61.5 Bq/m3, respectively. The annual effective doses to radiation workers caused by radon concentrations in underground workplaces were 0.57-0.83 mSv, with an average of 0.69 mSv. There was a significant difference in radon concentrations among provinces (P < 0.05). Conclusion The indoor radon concentrations and personnel exposure doses in the underground workplaces of monitored medical institutions comply with national control standards. However, continuous monitoring and necessary indoor radon prevention and control measures are still needed.
4.Current status of quality control of kV X-ray radiotherapy equipment
Zechen FENG ; Zihan WANG ; Yongzhong MA ; Hui XU ; Qiao MA ; Hailiang LI
Chinese Journal of Radiological Health 2024;33(4):466-471
kV X-ray radiotherapy was the primary mode of radiotherapy widely used to treat many types of cancer, including deep tumors, before the invention of the Co-60 therapy machine and the electron linear accelerator, which gradually replaced kV X-ray radiotherapy. kV X-ray radiotherapy equipment requires less space and shielding, and still has application value in the treatment of skin lesions and superficial tumors. Especially in recent years, kV X-ray has been used in the treatment of keloid, and electronic brachytherapy equipment has been used in intracavitary, intraoperative, and superficial radiotherapy. Therefore, kV X-ray radiotherapy has seen renewed application. The quality control of kV X-ray radiotherapy equipment is the key to ensure the treatment effect and safety of patients. This paper reviews the current status of quality control of kV X-ray radiotherapy equipment and provides a reference for the formulation of quality control assessment standards for kV X-ray radiotherapy equipment.