1.Effects of NO synthesis inhibition on pain threshold and binding capacity of NMDA receptor of hippocampus in rats
Yongwei WANG ; Weidong MI ; Pingping ZUO
Chinese Journal of Anesthesiology 1996;0(08):-
Objective To investigate the effects of NO synthesis inhibition on pain threshold and binding capacity of NMDA receptor of hippocampus in rats. Methods Sixty-six SD rats of both sexes weighing (210 ? 20)g were randomly divided into 11 groups of six. Group I was used for determination of baseline values of pain threshold and binding capacity of NMDA receptor. In the five L-NAME groups (group Ⅱ-Ⅵ) 1% L-NAME in normal saline 50mg?kg-1 was given intraperitoneally (IP) . In the acute experiment pain threshold was determined 15 min (group Ⅱ ) and 30 min (group Ⅲ) after L-NAME IP injection. In the chronic experiment L-NAME 50mg?kg-1 was given IP twice a day for 1 day (group Ⅳ), 4 d (group Ⅴ) and 7 d (group Ⅵ) and pain threshold was measured 12h after last L-NAME administration. Group Ⅶ-Ⅺ served as control groups in which normal saline was given IP instead of L-NAME. Pain threshold was measured by response latencies following CO2 laser stimulation which was delivered to the medial surface of the ear. After determination of pain threshold the animals were decapitated and hippocampus was removed. The binding capacity of NMDA receptor with [3H] MK-801 was determined. Bmax and KD were determined by Scatchard analysis. Results There was no significant difference in pain threshold and binding capacity of NMDA receptor between group Ⅱ ,Ⅲ (acute experiment) and their control groups ( Ⅻ,Ⅷ). In chronic experiment pain threshold significantly increased after 1 and 4 d of L-NAME administration (group Ⅳ and Ⅴ) but return to the baseline value on the 7th day. NMDA receptor binding capacity increased in all three groups of chronic experiment. Bmax was significantly higher than the baseline value on the 4th and 7th day (group Ⅴ and Ⅵ). KD was significantly higher than the baseline value on the 4th day (group Ⅴ) but returned to the baseline on the 7th day (group Ⅵ) . Conclusions In chronic experiment NO synthesis inhibition can increase pain threshold to laser thermal nociceptive stimulation and induce changes in the affinity and density of NMDA receptor.
2.Working Principle and Application of Adaptive Support Ventionlation
Yongwei MI ; Yiyong LI ; Chi GUO
Chinese Medical Equipment Journal 1989;0(04):-
By introducing the basic concept and principle, the advantages and characteristics of ASV technology are highlighted. Based on clinical application, suggestions on how to correctly set ASV parameters are given.
3.Research and Application of SPR Sensor Technique in Biomedical Engineering
Yongwei MI ; Guohua LIU ; Wei ZHANG
Chinese Medical Equipment Journal 1993;0(06):-
The major developments in SPR technology are reviewed.The principle,parameters and configurations of SPR sensors are also introduced.Then the applications and future prospects of SPR sensor technology in biomedical engineering area are discussed.It is pointed out that the development of this technology tends to further improve the detection sensitivity and resolution,multi-channel detection,the array of micro-devices,etc.
4.Status, Causes and Countermeasures of Medical Equipment Quality Control in Military Hospitals
Chi GUO ; Yongwei MI ; Yiyong LI
Chinese Medical Equipment Journal 2003;0(11):-
Quality control of medical equipment is very important to the diagnostic accuracy and the cure effect. The work of the quality control is the main technical basis of the hospital construction in promoting medical development, and it's also an important content of the modem medical management. The status, causes and countermeasures of medical equipment quality control in military hospital at the present time are analyzed and discussed.
5.Research on intelligent quality control platform of ECG monitor
Tao LI ; Yiyong LI ; Shiqiang ZHENG ; Yongwei MI ; Chi GUO
Chinese Medical Equipment Journal 2015;36(5):86-88
Objective To design a set of quality control management platform of ECG monitor in order to evaluate the quality of ECG monitor quickly and objectively and monitor and record the whole course of quality control.Methods The quality control platform was designed with the existing ECG monitor quality control methods, the existing detection devices, database technique and digital recognition technique based on neural network.Results The platform could be used for the intelligent data acquisition, data recognition, data analysis and statistics of ECG monitor quality control.Conclusion The platform may enhance the quality control of ECG monitor greatly.
6.Current Status and Development of Electric Operating Table
Chi GUO ; Yongwei MI ; Yiyong LI ; Sui ZHANG
Chinese Medical Equipment Journal 2003;0(10):-
This article describes the functions and technical information based on the introduction of classification and theory of the operating table.Considering about the situation of manufacturers and applications,it also analyzes the current application status.According to the experience,it provides a means of maintenance and management.Finally,it introduces some kinds of multi-functions and professional electric operating table,and also figures out the developing trend of the separated electric operating system.
7.Design and development of centralized management and sharing system of medical equipment
Yongwei MI ; Ruichang WU ; Yiyong LI ; Kai ZHANG ; Wei WANG ; Tao LI
Chinese Medical Equipment Journal 2017;38(2):59-62
Objective To solve the problems in medical equipment utilization,supervision,management,clinical safety and etc.Methods A centralized management and sharing system of medical equipment was developed with functional requirements analysis,C/S architecture and programming.Results The system eliminated the needs for manual accounting and allocation,enhanced medical equipment usage rate and improved equipment borrowing procedure.Conclusion The system contributes to dynamic management and efficacy evaluation of medical equipment,so as the working efficiency can be increased while the costs can be decreased for manpower and materials.