1.Determination of Baicalin in Fuke Yangkun Pill by HPLC
Yongshu LIANG ; Hai LIN ; Yixin LI
Traditional Chinese Drug Research & Clinical Pharmacology 1993;0(04):-
Objective To establish a method for the determination of Baicalin in Fuke Yangkun pills.Method High-performance liquid chromatography method was used.The chromatographic conditions were as follows:C18 column,mobile phase of methanol ∶0.4 %phosphoric acid(45 ∶55),detection wavelength being 280 nm,a flow rate of 1.20 mL?min-1 and the column temperature being 25 ℃.Results There existed a good linearity when the injection quantity is in the range of 0.0541 ?g to 0.5408 ?g.Average recovery is 99.98 %,and RSD is 1.32 %.Conclusion HPLC method is simple and effective and can be applied for the detemination of Baicalin in Fuke Yangkun pills.
2.OPTIMIZATION OF EXTRACTION PROCESS OF SIMIAOYONGAN DECOCTION BY OR-THOGONAL TEST
Lin MA ; Yongshu LIANG ; Qi DUAN
Modern Hospital 2014;(8):82-84
Objective To research the best extracting technology of simiaoyongan decoction.Methods As the total contents of chlorogenic acid and harpagoside to be evaluation indicator, adopted L9 (34 ) orthogonal design to select out the best extraction.The main determination was by HPLC method.Results Accounted by the total contents of the two composi-tions, the influential effects of the experimental results were extraction solvent >reflux times >the volume of extraction>the circumfluence time.Conclusion The best extracting technology is adding 10-fold times of 50% alcohol, percolating 1 hours, and three times.
3.Analytical performance of high-sensitivity cardiac troponin I detection by VITROS ECIQ with enhanced chemiluminescence method
Yongshu LI ; Haiqing LIANG ; Xuejing HAN ; Ping SHI ; Kegang JIA
Chinese Journal of Laboratory Medicine 2015;(7):461-465
Objective To evaluate the performances of high-sensitivity cardiac troponin I ( cTnI ) on VITRO ECIQ with enhanced chemiluminescence method .Methods This verification study validated the limited of detection,function sensitivity,imprecision,linearity of the high-sensitivity cardic troponin used VITROS ECIQ according to the document EP-17A, EP-6A,EP-15A published by Clinical and Laboratory Standards Institute (CLSI) and determined 99th percentiles.All 652 patients with chest pain on immediate admission in TEDA International Cardiovascular Hospital during January to November 2013 were enrolled in this study.Including 323 cases of acute ST segment elevation myocardial infarction and non ST segment elevation myocardial infarction patients as the case group , exclude 329 cases of other diagnosis ,303 cases of apparent normal people as control group .The receiver operating characteristic curve was used to evaluated the sensitivity and the specificity of cTnI . Non-normal distribution of quantitative data were used nonparametric test Mann-Whitney U, With P<0.05 for the difference was statistically significant .Results The LoB was 0.006 5 ng/ml and the LoD was 0.015 5 ng/ml;the FS was 0.016 76 ng/ml;repeatability CV
was 1.73 % -2.33 %, reproducibility CV was 4.93% -9.96%.The imprecision were lower than that declared by assay producer.The linearity was 0.015 5-78.4 ng/ml(R2 =0.999 9); the 99th percentile reference value was 0.017 ng/ml.The area under the curve ( AUC) of cTnI was 0.986,95%CI 0.973 -0.994,with the cut-off value as 0.017 ng/ml, the diagnostic sensitivity and specificity in CIN were 90.09%and 99.34%.Compared between STEMI and NSTEMI groups after admission , the levels of cTnI had no significantly difference , Z were -0.485, P >0.05;compared between STEMI and control groups after admission, the levels of cTnI had significantly difference , Z were -19.567,P<0.001;compared between NSTEMI and control groups after admission , the levels of cTnI had significantly difference , Z were-14.598,P<0.001.Conclusions High-sensitivity cardiac troponin I detection by VITROS ECIQ with enhanced chemiluminescence method has good performances of sensitivity , linearity, specificity, which meet the clinical needs.
4.The application value of MSCT angiography in posterior approach of upper cervical vertebrae
Guidong DAI ; Kali LIANG ; Zhengyuan XIAO ; Yongshu LAN
Journal of Practical Radiology 2014;(11):1802-1804,1809
Objective To explore the application value of multi-slice CT angiography (MSCTA)in posterior approach of upper cervical vertebrae.Methods Fifty-one patients with suspected or conformed upper cervical disease were collected and performed cer-vical CTA examination.Twenty three patients underwent internal fixation surgery of posterior upper cervical and reviewed with CTA examination.Volume Render (VR),Maximum Intensity Projection (MIP)and Multi-planar Reformation (MPR)were used to show the courser and anatomical variation of vertebra artery,the shape of vertebrae,the relationship between the vertebra artery and adjacent structure,advantage artery.The distribution of screw placement,including perforation of the anterior wall,the inner wall, the outer wall,the upper wall,the interior wall and the inner wall of occipital were observed by VR,MIP and MPR after surgery, especially the relationship between the screw and vertebra artery,the screw and spinal cord.Comparing the correlation between the screw placement and postoperative symptoms.SPSS1 9.0 statistical packages were used for statistical analysis.Results VR,MIP and MPR can show the courser and nearby space relationship of cervical artery.The number of advantage artery was 25,equilibra-tion was 26,dysplasia variation was 13,course variation was 4.The number of tiny pedicle was 1 6,including 9 cases of ipsilateral advantage artery.The postoperative data analysis of 23 patients showed that:C1 -20,C2 -36,C3 - 1 5,C4 -2,occipital 40.The number of accurate screw placement was 83.Different type of perforation was 30,including 3 screws closing to vertebra artery,1 screw closing to spinal cord.All 23 patients were asymptomatic after surgery.Conclusion MSCTA can reflect the morphology of cervical vertebral,the spatial relationship between cervical vertebral and surrounding structure,which can provide an accurate refer-ence for clinical screw placement and improve the accuracy .The postoperative CTA can show screw placement accurately,which has great reference for the evaluation of clinical success rate of surgery and post-surgery treatment.
5.To evaluate early dynamic contrast enhancement CT on multiple organ failure in acute pancreatitis
Yunchuan XIE ; Liang XUE ; Fugang HAN ; Jian SHU ; Guangcai TANG ; Mingming DENG ; Yongshu LAN
Journal of Practical Radiology 2017;33(11):1699-1702
Objective To evaluate early dynamic contrast enhancement CT on multiple organ failure in acute pancreatitis.Methods 333 cases of acute pancreatitis identified by clinical and early dynamic contrast enhancement CT were collected.Patients were divided into organ failure group(OF group,124 cases) and non-organ failure group (notn-OF group,209 cases).All variables including duration of hospitalization,need for intensive care unit,infection,need for operation,mortality and MCTSI,EPIC score were analyzed by U test and x2 test firstly.The variables with significance (P<0.05) were analyzed by Stepwise Logistic regression further.Results On U test and x2 test,there were significant differences(P<0.001) between two groups in duration of hospitalization,need for intensive care unit,infection,need for operation,mortality,MCTSI score and EPIC score and APFC + ANC> 100 mL,and bilateral pleural effusion/ pulmonary atelectasis.The Stepwise Logistic regression analysis demonstrated that increased MCTSI and EPIC score,APFC+ANC> 100 mL and bilateral pleural effusion/pulmonary atelectasis were 4 independent risk factors of multiple organ failure in acute pancreatitis.Conclusion Multiple organ failure in acute pancreatitis can be judged with early dynamic contrast enhancement CT for improved treatment.
6.A potential role of plasma circulating microRNA-30d in acute coronary syndrome
Ping SHI ; Kegang JIA ; Xiongguan WANG ; Haiqing LIANG ; Junfeng LIU ; Xuejing HAN ; Yongshu LI ; Hongxia TANG
Chinese Journal of Laboratory Medicine 2018;41(2):97-102
Objective To investigate the diagnosis and prognosis value of plasma microRNA-30d (miR-30d)in acute coronary syndrome(ACS)patients.Methods It retrospectively recruited 170 cases of ACS patients from TEDA International Cardiovascular Hospital between September 2011 to February 2012, including 70 STEMI(male 54,female 16), 52 NSTEMI(male 34,female 18),48 UAP(male 29,female 19).At the same time,41 healthy controls(male 24,female 17)were enrolled into the study.Plasma miR-30d levels were determined by real-time quantitative PCR.In order to evaluate the dynamic change of miR-30d and other cardiac biomarkers,20 plasma samples of AMI patients were collected at 0-3 h,4-6 h,7-9 h, 10-12 h after pectoralgia.ROC curves and Kaplan-Meier survival curve were used to investigate clinical value of miR-30d in ACS.Results At 0-3 h after pectoralgia, miR-30d were significant higher in STEMI 7.208(0.170-11 070.735)and NSTEMI 7.989(0.836-151.391)than the controls 1.561(0.044-17.520)(Z1=-5.792,Z2 =-6.113,P<0.001), but there were no statistic differences between UAP 1.073 (0.051-11.095)patients and the controls(Z=-0.325,P=0.745).In 20 AMI patients,miR-30d levels peaked at 4-6 h and then dropped following 7-9 h, both earlier than cTnI, and the variation tendency was positive correlated with cTnI(r=0.402,P<0.01).At 0-3 h after pectoralgia, the AUC, sensitivity and specificity of miR-30d for differentiating AMI and UAP were 0.882(95% CI:0.830-0.935),0.795(95%CI:0.711-0.861)and 0.854(95% CI:0.716-0.935)respectively.When combined miR-30d and cTnI, the diagnostic AUC and specificity were 0.937(95% CI: 0.902-0.972)and 0.937(95% CI:0.818-0.984),both enhanced when compared with miR-30d or cTnI alone.Kaplan-Meier survival curves revealed that there were no significant correlations between the miR-30d levels and MACE in both 30 days and 12 months(χ$lt@span sup=1$gt@2$lt@/span$gt@=0.506,P=0.477 and χ$lt@span sup=1$gt@2$lt@/span$gt@=0.002, P=0.963 respectively).Conclusion Plasma miR-30d may be used as a potential biomarker for early diagnosis, but not prognosis in ACS patients.