1.Discussion On Scheme For PACS Storage
Chinese Medical Equipment Journal 2003;0(11):-
Objective To layout the storage of hospital Picture Archiving and Communication System (PACS) in long term. Methods As an example for updating the PACS storage in our hospital, the scheme for PACS storage was presented to show how to improve the storage layout using the existing network topology and hospital information system for future update of storage. Results The selection and determination of scheme for PACS storage is relative to the long-term layout on hospital information construction. Conclusion Reasonable storage of PACS is an essential step in hospital digitization.
2.Preparation of Anhydrous Hand-cleaning Agents
Yongshi HU ; Xianhai JIANG ; Cunhe LIN ; Geqiong ZHANG ; Qingyun DU
China Pharmacy 1991;0(03):-
OBJECTIVE:To prepare anhydrous iodine-containing or iodine-free hand-cleaning agents for use at field or water-deficient area.METHODS:An adhesive paste was made with PVA as vehicle and PVP-I as disinfector.Iodine value was taken as parameter of quality control.The adhesive-eliminating test was carried out on Escherichia coli and HBV elimi?nating and skin irritation tests were performed in rabbits.RESULTS:This preparation could eliminate bacteria by its adhesive action and had considerable disinfective action because of the ingredient iodine,however it could not eliminate HBV.No irrita?tion to skin was found.CONCLUSION:The preparation can effectively remove the dust,bacteria and viruses from the hands and is suitable for cleaning hands in conditions of wartime,training and water-deficient area.
3.Effect of dynamics of instantaneous flow rate on the quantification of the severity of degenerative mitral regurgitation using M-mode proximal isovelocity surface area
Chunqiang HU ; Zhenyi GE ; Shihai ZHAO ; Fangyan TIAN ; Wei LI ; Lili DONG ; Yongshi WANG ; Dehong KONG ; Fangmin MENG ; Zhengdan GE ; Xianhong SHU ; Cuizhen PAN
Chinese Journal of Ultrasonography 2023;32(7):590-599
Objective:To investigate the effect of instantaneous flow rate on the consistency of diagnostic accuracy of severe degenerative mitral regurgitation (DMR) using proximal isovelocity surface area (PISA).Methods:From June 2019 to June 2021, 75 patients with DMR who underwent echocardiography in Department of Echocardiography of Zhongshan Hospital, Fudan University were prospectively enrolled. The instantaneous flow rate of DMR during the systolic phase was calculated using M-mode PISA(PISA M-mode), and a time-integrated curve was plotted. Regurgitant volume (RVol) and effective regurgitant orifice area (EROA) were calculated by traditional PISA (PISA max), pair PISA (PISA pair), and PISA M-mode, respectively. RVol acquired from cardiac magnetic resonance (CMR) volumetric method in 22 patients of the enrolled patients. The correlation and consistency of RVol acquired between the three PISA methods and CMR were compared. Agreement of diagnostic accuracy of severe mitral regurgitation (sMR) acquired between the three PISA methods and multi-parameter algorithm by American Society of Echocardiography (ASE) was analyzed using Cohen′s Kappa analysis. Results:The curve of instantaneous flow rate of DMR showed unimodal pattern with the peak at mid-late systolic phase. The correlation of RVol acquired between PISA methods and CMR was moderate for PISA max and PISA pair ( r=0.77, 0.80, both P<0.001), whereas PISA M-mode presented strong correlation with CMR ( r=0.87, P<0.001). RVol acquired from PISA max was larger than that of CMR[(69.1±37.1) ml vs (49.0±29.0)ml, P=0.002]. Both PISA max and PISA pair were shown moderate agreement of diagnostic accuracy of sMR with ASE multi-parameters algorithm (RVol: κ=0.496, 0.525, both P<0.001; EROA: κ=0.570, 0.578, both P<0.001), while PISA M-mode presented strong agreement (RVol: κ=0.867 and EROA: κ=0.802, both P<0.001). Conclusions:Based on the unimodal pattern of instantaneous flow rate in patients with DMR, PISA max may significantly overestimate RVol, exposing a significant proportion of patients with DMR to unnecessary MR surgery. PISA M-mode presents better correlation and consistency with CMR on the quantification of RVol compared with PISA max and PISA pair, and may improve the diagnostic accuracy of quantification of sMR using PISA.