1.Hyponatremia after acute cervical spinal cord injury
Yongqing JIANG ; Daming DONG ; Yansong WANG
Orthopedic Journal of China 2006;0(24):-
[Objective]To investigate the pathogenesis,pathology,diagnosis and therapy of hyponatremia after acute spinal cord injury.[Method]Fifteen in-patients with hyponatremia after acute spinal cord injury from 2004 to 2006 were retrospectively analyzed.[Result]Serum sodium was lower than 130 mmol/L in all cases.Urine sodiumcanned was from 40 to 68 mmol/L and urine osmotic pressure was from 420 to 980 mmol/L.After limitation of water intake and appropriate salt intake,12 patients recovered at 2 to 3 weeks.Because of fever and avoiding limitation of water intake,the other 3 patients recovered slowly.[Conclusion]The more serious the acute spinal cord injury,the higher the frequency of hyponatremia;syndrome of inappropriate antidiuretic hormone secretion(SIADH) is its primary cause: appropriate measures should be taken to correct the hyponatremia according to the findings of serum sodium and urine osmotic pressure.
2.Effects of β-elemene combined with chemotherapy on the protein expressions in lung adenocarcinoma A549 cell line
Xinhai ZHU ; Yongqing WANG ; Zhiming JIANG ; Zhibing WU
Chinese Journal of Geriatrics 2011;30(11):962-964
ObjectiveTo explore the possible molecular mechanisms of β-elemene combined with cisplatin and heat therapy for killing A549 cell line.MethodsThe protein expressions of Stat3,p21 Waf1/Cip1 and Survivin were detected with Western blot after treatment with β-elemene of different concentrations combined cisplatin and heat therapy.ResultsThe protein expressions of Stat3,and pStat3 and p21Waf1/Cip1 in A549 cell line were enhanced with increasing concentrations,and there was significant difference in the expressions between high and low concentration,but Survivin protein had no change at 37°C.After adding 4 μg/mL cisplatin,the expressions of p21Waf1/ Cip1,Survivin,Stats and pStat3 were reduced at β-elemene of high concentration.At 42°C,there was no significant difference in expression of Stat3 protein at 60 μg/mL elemene,but the expressions of pStat3,p21Waf1/Cip1 and Survivin proteins had sharply declined.When using 15 μg/mL elemene combined with 4 μg/mL cisplatin,the protein expressions of Star3 and pStat3 increased,and Survivin expression decreased.ConclusionsAt temperature of 37°C,β-elemene of high concentration may inhibit growth of A549 cells by higher expression of p21Waf1/Cip1 protein,and mainly by inhibiting expressions of Stat3 and pStat3 and Survivin after combined with cisplatin.At temperature of 42°C,β- elemene of highconcentrationmaypromoteapoptosispossiblythroughinhibition ofStat3 phosphorylation and expression of Survivin protein.β-elemene of low concentration combined with cisplatin leads to synergy killing effect by reducing expression of Survivin protein.
3.Synthesis and Characterization of a Novel ELF-97-based Fluorescent Probe for Hydrogen Peroxide Detection
Zijun CAI ; Yongqing KUANG ; Dan PAN ; Wei LIU ; Jianhui JIANG
Chinese Journal of Analytical Chemistry 2015;(11):1671-1675
A novel 2-( 2’-hydroxy-5’-chlorophenyl )-6-chloro-4 ( 3 H )-quinazolinone ( ELF-97 )-based fluorescent probe (P1) for hydrogen peroxide was prepared from 5-chlorosalicylaldehyde, 4-(bromomethyl) phenylboronic acid and 2-amino-5-chlorobenzamide, and its structure was characterized by 1 H NMR, 13 C NMR and HRMS. Weak fluorescence intensity was observed at 425nm when the solution of probe P1 was excited by 360 nm UV light. After addition of H2 O2 , however, emission peak at 425 nm disappeared while strong peak emission at 515 nm appeared with the same excitation wavelength ( 360 nm ) . The fluorescence intensity at 515 nm was dependent on the concentration of H2 O2 in the linear response range of 5-45 μmol/L. The detection limit of H2O2 was 0. 1 μmol/L (S/N=3) and the recovery rates of added H2O2 in milk were in the range of 94 . 0%-106 . 0%. Probe P1 was potential to become a useful tool for rapid detection of hydrogen peroxide.
4.Postoperative echocardiographic evaluation of modified Blalock-Taussig shunts
Yisheng SHI ; Hao WANG ; Yongqing LI ; Li JIANG
Chinese Journal of Ultrasonography 2008;17(3):204-206
0bjective To summarize the experience of postoperative and mid-term echocardiographic evaluation of modified Blalock-Tasussig(BT)shunts. Methods During 2003-2006,thirty five consecutive patients received modified BT shunts and survived postoperative 6 months were enrolled in this study.Transthoracic echocardiography was utilized to evaluate the patency of shunts and the change of pulmonaryarteries(PA)and left ventricle(LV). Results Three patients received the emergence surgery for the intervention for the BT shunts. The follow-up was (21.2±11.3) months. During the follow up,the obstruction of shunts occurred in 7 cases. After the placement of shunts,the mean size of PA increased by 31.2%,meanwhile,the size of LV increased by 25.6%. Nineteen patients received the followed definitive repair or palliative operations. Compared with the patients still waiting for the growth of PA,the patients who receiving the second staged procedure achieved the more appropriate PA growth. Furthermore,for the above patients,there was no significant difference between the angiographic and echocardiographic evaluation for the PA size. Conclusions Echocardiography could accurately diagnose the patency of shunts and record the growth of PA and LV following BT shunts. Echocardiography is a highly reliable noninvasive approach for the perioperative evaluation and mid-term follow-up for the modified BT shunts.
5.The expression of erythropoietin receptor in the spinal cord after acute traumatic injury in adult rats
Yan-Song WANG ; Meng YAO ; Bin LIU ; Daming DONG ; Yongqing JIANG ; Congyi SUN ;
Chinese Journal of Orthopaedic Trauma 2004;0(09):-
Objective To investigate the expressions of erythropoietin(EPO)and its receptor(EPO-R)in the spinal cord after acute traumatic injury in adult rats.Methods Sixty-nine Wistar rats were randomly divided into three groups:normal control group(n=5),spinal cord injury group(n=32),and sham operation group(n= 32).The injury group and sham operation group were further randomly divided into eight subgroups respectively (n=4)(1h,6h,12h,24h,3d,7d,14d,28 dafter operation).The expressions of EPO and EPO-R at different time points were detected by RT-PCR,Western blot and immunohistochemical staining.Results EPO was nut detected at any time point in the normal control grnup,spinal cord injury group or sham operation group.The EPO-R expression was not found in the normal control group or sham operation group.RT-PCR and Western blot analyses revealed EPO-R mRNA and protein expressions in the injury group as early as 6 h after injury.The EPO-R mRNA and protein expressions sharply increased at 12 h,peaked at 24 h to 7 d,and gradually declined after 7 d. They were still higher than those in the control rats 28 d after injury.The EPO-R immunoreactivity was chiefly found in neurons,oligodendrocytes,vascular endothelial and ependymal cells.Conclusion The EPO-R expression can be up-regulated obviously in the injured spinal cord,which provides a molecular basis for the nerooprotection of exogenous EPO.
6.The influence of continuous high volume hemofiltration on respiratory mechanics and hemodynamics in patients with multiple organ dysfunction syndrome
Jian XIE ; Jun YANG ; Tao LI ; Yongqing XU ; Zhiming JIANG ; Ming ZHANG ; Zhonghui ZHANG
Chinese Journal of Postgraduates of Medicine 2011;34(1):13-15
Objective To investigate the effect of continuous high volume hemofiltration (HVHF)on respiratory mechanics and hemodynamics in multiple organ dysfunction syndrome (MODS). MethodsForty-one adult patients with MODS who received mechanical ventilation were divided into HVHF group(21 cases) and continuous vein-vein hemofiltration (CVVH) group (20 cases) by envelople. The peak airway pressure (Ppeak), dynamic pulmonary compliance(Cdyn), cardiac output(CO ), systemic vascular resistance(SVR), pulmonary vascular resistance (PVR) and blood gas analysis before treatment and 24 hours after treatment were measured. Results Twenty-four hours after treatment, the levels of Ppeak, Cdyn, CO, PVR,SVR and oxygenation index were (31.32 ±2.23) cm H2O (1 cm H2O =0.098 kPa), (26.18 ±3.54)(220.41 ±21.41) mm Hg (1 mm Hg =0.133 kPa) respectively in HVHF group,significantly higher than those before treatment [(42.00 ±3.34) cm H2O, (17.91 ±4.31) ml/cm H2O, (8.68 ±1.17) L/min,(267.27 ± 16.29) dyn·s·cm-5, (805.32 ± 18.82)dyn ·s·cm-5, ( 119.41 ± 17.10) mm Hg] (P < 0.01 ),as well as higher than those in CVVH group after 24 hours' treatment (P < 0.01 ). ConclusionHVHF shows significant beneficial effects on respiratory mechanics and hemodynamics of MODS.
7.Analysis on risk factors of re-fracture after operation of osteoporotic hipfracture
Lei REN ; Yongqing SUN ; Jingdong HAO ; Zhun CUI ; Yunyi HAN ; Yuxin JIANG ; Kaifeng JIN
Chinese Journal of Postgraduates of Medicine 2017;40(4):301-304
Objective To investigate and analyze risk factors of re-fracture after operation of osteoporotic hip fracture.Methods Two hundred forty-seven patients receiving operation of osteoporotic hip fracture were retrospectively studied and followed up,and all patients were divided into re-fracture group (54 patients) and no-re-fracture group (193 patients).The related factors such as sex,age,body mass index (BMI),affected side,initial fracture site,operation type,perioperative blood loss,postoperative delirium,postoperative bedridden time,medical complications,Charlson comorbidity index,antiostoporosis therapy,hip function scores with Harris and functional independence measurement (FIM) scores were compared by single factor analysis and multivariate Logistic regression analysis.Results Single factor analysis and multivariate Logistic regression analysis both showed that the risk factors of re-fracture after operation of osteoporotic hip fracture included age,postoperative delirium,hypertension,diabetes mellitus,cerebrovascular disease,antiostoporosis therapy,hip function scores with Harris and FIM scores (P < 0.05 or < 0.01).Conclusions Risk factors of re-fracture after operation of osteoporotic hip fracture include passive factors of age,postoperative delirium and medical complications,and subjective factors of antiostoporosis therapy,hip function scores with Harris and FIM scores.Patients should receive medical treatment positively,enhance antiostoporosis therapy and rehabilitation training of hip function to prevent re-fracture.
8.An investigation of prehospital medical care of sudden mass incident in Guangzhou from 2001 to 2010
Peiyi LIN ; Xiaohui CHEN ; Huilin JIANG ; Haifeng MAO ; Binfan LIU ; Yongqing QI ; Xin LAI ; Shuangming LI
Chinese Journal of Emergency Medicine 2012;21(6):661-664
ObjectiveTo investigate the type,characteristics and development trend of prehospital medical care of sudden mass incident from 2001 to 2010 in Guangzhou.MethodsThe data of prehospital medical care of sudden mass incident in Guangzhou from 2001 to 2010 were come from the database of 120 Emergency Center.ResultsTotal 6 807 events of Sudden mass incident were recorded from 2001 to 2010,resulting in 26 749 injuries and 917 deaths.In all kinds of sudden mass incident,traffic accident was primary cause ( the number of cases,injuries and deaths accounted for 49.80%,55.29% and 61.72%,respectively),followed by fighting,fire and poisoning.Over the past decade,the number of occurrence of traffic accidents and the number of injuries were increasing.The large sudden mass incident was 76.65% in all levels of sudden mass incident happened from 2008 to 2010.Conclusions Traffic accident is an important cause of sudden mass incident in Guangzhou from 2001 to 2010.The number of the traffic accident cases and injuries were increasing.The large sudden mass incident was the main type in all levels of sudden mass incident.It is important to improve the emergency plan,strengthen the training of medical staff and organize the medical rescue drill of sudden mass incident regularly.
9.Application of Quality Control Circle for reducing health checkup report's error rate
Qianping CHEN ; Jingfei YU ; Xiaoling LIN ; Yongqing JIANG ; Beilei DAI ; Huina CAI
Chinese Journal of Health Management 2016;10(6):439-444
Objective To explore the effect of quality control circle (QCC) in reducing the health examination report errors. Methods QCC was founded, activity themes were selected, activity schedule was planned, the reasons of health examination report errors were analyzed, goal setting, countermeasures were planned and implemented jointly by circle members. Totally 11 738 reports of health checkup were selected and analyzed the errors were analyzed during the activity, 6 892 were male, 4 846 were female, their average age was(38.01 ± 11.31)years, 5 000 reports were made before improvement, 5 120 reports during improvement, 1 618 reports after improvement and compared the report error rates were compared. Evaluation of QCC activity results and tracking effect were evaluated. Results Error rate of health checkup report from 17.80‰ decreased to 7.23‰ during improvement, dropped to 2.48‰ after improvement. The rate of standard was 141.9%, progress rate was 86.1%. Tracking results for 8 months, error rate remained below the target value of 3.40‰although error rate roise to 5.25‰in August 2016, the effect was good. The additional benefit, working efficiency of the doctors was improved; Average time for each written report was reduced to 4 minutes from 5 minutes;Saved about 1 hours per person a day to review the accuracy of the report and learning; Formed“communication model between clinical departments”;Established the error registration system for the report has been distributed;Similar error of ECG department has been avoided. Conclusions Application of QCC not only reduced the error rate of the health checkup report, but also ensured quality, objective, and accurate physical examination report; activities not merely help to improve the work efficiency of physician, team's mutual cooperation, and is beneficial to optimize the system of medical institution and avoid the error.
10.Comparison of region of interest volume between three different treatment planning systems
Wei WANG ; Mawei JIANG ; Songfang ZHANG ; Yuanzi ZHA ; Yichen SHENG ; Yongqing TU
Chinese Journal of Radiation Oncology 2017;26(1):74-78
Objective To analyze the differences between calculated and actual volumes of regions of interest ( ROIs) in three treatment planning systems ( TPSs):PrecisePlan, Xio, and Oncentra, to transfer different ROIs and compare their calculated volume between the three TPSs, and to provide a basis for clinical application. Methods Different sizes of ROIs were delineated on 5 sets of computed tomography ( CT) images with different slice thickness. Square and round regions with different slice numbers were contoured in a homogeneous phantom. Three groups of patients ( n=5) with head and neck tumor, chest and abdomen tumor, and pelvic tumor, respectively, were enrolled as subjects. All the ROIs were independently transferred back and forth between three TPSs and different workstations with the same system in DICOM RT format. The changes in actual and calculated ROI volumes were evaluated after back and forth transfer. Results There was a significant positive linear correlation between the calculated volume, slice thickness, slice number, and actual volume of ROI in each TPS ( PrecisePlan:R2=0. 994, P<0. 01;Xio:R2=0. 997, P<0. 01;Oncentra:R2=0. 995, P<0. 01) . There were significant differences in all calculated ROI volumes of the head, chest and abdomen between the three TPS ( P<0. 05) except for the calculated ROI volumes of the chest and abdomen between Oncentra and Xio ( P=0. 114 ) . Conclusions The variations in volume calculation algorithm and slice thickness are the main causes of differences in calculated ROI volume. Particularly, small?volume ROIs have the greatest variation in calculated volume. To avoid a secondary reconstruction of ROI volume, it is recommended to transfer ROI back and forth between dose calculation workstations with the same TPS.