1.Ultrasonographic characteristics of biliary stricture after orthotopic liver transplantation
Yongjiang MAO ; Rongqin ZHENG ; Jie REN ; Dongmei HUANG ; Bo ZHANG
Chinese Journal of Ultrasonography 2008;17(12):1045-1047
Objective To evaluate the charateristics of biliary stricture after orthotopic liver transplantation(OLT) by ultrasound. Methods Diametes,thickness,characteristic echo of bile were observed by ultrasound in 41 patients with biliary stricture after OLT,and the results were compared with those of 46 patients without biliary complication after OLT.Results The diameter of intrahepatic bile,thickness of bile,incidence of intrahepatic bile dilation or hyperechogenicity in biliary stricture patiens were higher than those in patients without biliary complication,there were significant differences between two groups(P<0.05).Conclusions The series of ultrasonographic character such as bile dilation,thickeness or hyperechogenicity of biliary wall,thin of bile duct are available to diagnose biliary stricture.
2.The application of RoSCo score in the laparoscopic partial nephrectomy
Yongjiang ZHUANG ; Chao CAI ; Huijian ZHANG ; Peidan PENG ; Shaobin ZHENG
The Journal of Practical Medicine 2017;33(7):1109-1112
Objective To investigate the association between the RoSCo scoring system and the postopera tive complications of laparoscopic partial nephrectomy.Methods The clinical data of 127 patients with laparoscopic partial nephrectomy in our hospital from 2010 to 2015 were retrospectively analyzed.By studying all patients' preoperative clinical data,we give all the patients the RoSCo score,then divided all the patients into the RoSCo low group (3-4),RoSCo moderate group (5-6),RoSCo high group (7-8).Respectively study the association between the RoSCo score and Clavein score,operative time,intraoperative blood loss,warm ischemia time and length of hospital stay after laparoscopic partial nephrectomy.Results The RoSCo score was associated with postoperative complications of laparoscopic partial nephrectomy (P < 0.05) and was more accurate than the RENAL score alone.There were significant differences in bleeding,warm ischemia time,hospital stay and operation time between the low,middle and high groups of RoSCo (P < 0.05).Conclusion The RoSCo scoring system can be used to assess the complications of laparoscopic partial nephrectomy.
3.Correlation between the Number of AgNOR and the Grading and Prognosis of Bladder Tumor
Dingwei YE ; Jiafu ZHENG ; Songxi QIAN ; Yongjiang MA
Academic Journal of Second Military Medical University 1981;0(03):-
The numbers of nucleolar organizer region (AgNOR) were counted by one-step silver colloid technique in 6 cases of normal bladder tissue, 9 chronic cystitis and 56 transitional cell carcinoma of bladder. The results revealed that the mean number of AgNOR per nucleus was not statistically different between normal bladder tissue and chronic cystitis while a significant difference was observed between normal, or inflammatory tissue and malignant tissue or between various grades of bladder tumor. The results also indicated that the mean number of AgNOR per nucleus was closely related to the prognosis of bladder tumor. So it is suggested that the AgNOR counting with silver stain technique may play a role in the differentiation of benign and malignant lesions and in the grading and prognosis of bladder tumors.
4.P53 Gene Mutations in Human Seminomas Screened by Using Polymerase Chain Reaction Technique
Dingwei YE ; Jiafu ZHENG ; Songxi QIAN ; Yongjiang MA
Academic Journal of Second Military Medical University 1985;0(05):-
Genomic DNA from 17 primary human tcsticular seminomas was screend for the presence of mutations in exon 5 - 8 of P53 gene, using the single strand conformation polymorphism assay, followed by direct DNA sequencing. P53 mutations in one alle'e leading to an amino acid change were identified in 4 of 17 seminomas. Sites of mutations were in exon 5(codon 141), exon 7 (codon 238, codon 258) and exon 8(codon 279). The present study suggests that mutation of P53 gene is involved in the development of human testicular seminoma.
5.Comparison between baseline and contrast-enhanced ultrasound in characterization of adnexal masses
Xinling ZHANG ; Zeping HUANG ; Rongqin ZHENG ; Yongjiang MAO ; Zhijuan ZHENG ; Xuqi HE ; Dongmei HUANG
Chinese Journal of Ultrasonography 2011;20(10):857-860
ObjectiveTo assess the diagnostic performance of contrast-enhanced ultrasound(CEUS)in characterization of adnexal masses in comparison with baseline ultrasound.MethodsOne hundred and thirty-seven masses were examined by CEUS and baseline ultrasound.Two independent investigators reviewed the images before and after contrast agent administration.The diagnostic performances were evaluated using receiver operating characteristic (ROC) analysis and the interobserver agreement was analyzed.ResultsAfter review of CEUS,ROC analysis revealed significant improvement in differentiating between malignant and benign pelvic masses that the areas under the ROC curve were 0.731 and 0.738 at baseline ultrasound versus 0.891 and 0.903 at CEUS ( P <0.01 ).The accuracy for both investigators also improved significantly after reviewing CEUS.A better interobserver agreement was achieved after reviewing of CEUS (g =0.681 at baseline ultrasound versus κ =0.893 at CEUS) and a better result of specific diagnosis was obtained (73.2% and 74.2% at baseline ultrasound versus 90.7% and 91.2% at CEUS)(all P < 0.01 ).Conclusions Real-time CEUS improves the diagnostic performance in adnexal masses for discrimination between malignancy and benignity and improves the capability in specific diagnosis compared with baseline ultrasound.
6.Characterization of complex pelvic masses with contrast-enhanced ultrasound
Xinling ZHANG ; Dongmei HUANG ; Rongqin ZHENG ; Zeping HUANG ; Yongjiang MAO ; Zhijuan ZHENG ; Xuqi HE
Chinese Journal of Ultrasonography 2011;20(11):968-971
Objective To assess the diagnostic performance of contrast-enhanced ultrasound in characterization of pelvic masses.Methods Contrast-enhanced ultrasound was performed on 137 patients with pelvic masses.The results were compared to pathological diagnostic criteria.The diagnostic performance was evaluated by using diagnostic test.Results Sensitivity,specificity,positive predictive value,negative predictive value,accuracy and area under ROC curve in diagnosing complex pelvic masses by using contrast-enhanced ultrasound were as follows:85.3% (29/34),93.2% (96/103),80.6% (29/36),95.0% ( 99/101 ),91.2% ( 125/137 ),0.892,respectively.Conclusions Contrast-enhanced ultrasound provides a simple and curate method for characterization of pelvic masses.
7.Contras-enhanced ultrasound features of ovarian tumor torsion
Xinling ZHANG ; Dongmei HUANG ; Yongjiang MAO ; Qian SONG ; Zhijuan ZHENG ; Yuhua LI ; Rongqin ZHENG
Chinese Journal of Ultrasonography 2010;19(3):245-247
Objective To investigate the contrast enhanced ultrasound(CEUS)features of ovarian tumor torsion(OTT).Methods Seventeen cases with OTT were evaluated using CEUS.CEUS was performed with low mechanical index and the contrast agent of Sono Vue.Results Thirteen cases with total torsion of ovarian tumor appeared as no enhancement.Four cases with partial torsion showecl hyperechoic enhancement in the early phase and hypoechogenicity in the late phase.Conclusions The enhancement of OTT has characteristic,which would be helpful for the diagnosis and differential diagnosis of OTT.
8.The value of contrast-enhanced ultrasound in the differential diagnosis of endometrial carcinoma and endometrial hyperplasia
Xinling ZHANG ; Dongmei HUANG ; Qian SONG ; Yongjiang MAO ; Zhijuan ZHENG ; Yuhua LI ; Rongqin ZHENG
Chinese Journal of Ultrasonography 2009;18(12):1061-1063
Objective To explore the value of contrast-enhanced ultrasound(CEUS)in the differential diagnosis of endometrial carcinoma and endometrial hyperplasia.Methods Forty-five patients with endometrial carcinoma and 21 patients with hyperplasia were studied by CEUS.Twenty-four normal women were enrolled as contrast group.Results In normal uterus, myometrium exhibited earlier enhancement later washout than the endometrium.Similar phenomenon was observed in patients with hyperplasia.In patients with endometrial carcinoma,the lesion showed wash-in and washout earlier, at least not later than the myometrium.Conclusions Endometrial carcinoma and hyperplasia showed different enhancement patterns,which may be helpful for the diagnosis of the two diseases.
9.Application of transperineal ultrasound in female urethras and pathological change of circum-urethras
Yongjiang MAO ; Zhijuan ZHENG ; Mei LIAO ; Zeping HUANG ; Rongqin ZHENG ; Xinling ZHANG
Chinese Journal of Ultrasonography 2014;23(9):791-793
Objective To investigate the application value of transperineal ultrasound in female urethras and pathological change of circum-urethras.Methods 403 female patients were examined by transperineal ultrasound in condition of resting and maximum Valsalva,female urethras and pathological changes of circum-urethras were observed and ultrasonic manifestation were concluded.Results By transperineal ultrasound the images of normal urethras and pathological change of circum-urethras were clearly discernible.403 female patients were examined,380 normal.18 urethral calcification,there was hyperecho stripe in urethras.2 urethral cyst,there was round anechoic area in circum-urethras and no fistula between round anechoic area with urethras.2 urethral diverticulum,there was round anechoic area in circumurethras and a fistula between round anechoic area with urethras.1 urethrovaginal fistula,there was irregular hypoechoic area between urethras with vagina,the irregular hypoechoic area both communicate with urethras and vagina.Conclusions Transperinealr ultrasound can be used for examination urethras and pathological change of circum-urethras in female patients and may provide more reliable information for clinical diagnosis.
10.Value of contrast-enhanced ultrasound for differential diagnosis of subserous myoma and ovarian fibroma
Xinling ZHANG ; Xuqi HE ; Rongqin ZHENG ; Yongjiang MAO ; Zeping HUANG ; Zhijuan ZHENG ; Dongmei HUANG
Chinese Journal of Ultrasonography 2013;(3):239-242
Objective To explore the value of contrast-enhanced ultrasound (CEUS) in the differential diagnosis of subserous myoma (SM) and ovarian fibroma.Methods CEUS was performed on 58 patients with SM and 26 patients with ovarian fibroma.The enhancement pattern was observed.The diagnostic performance was evaluated by using diagnostic test.Results SM exhibited homogeneous isoenhancement synchronously with the myometrium in early phase.In the late phase,the pseudocapsule remained hyper-enhancement with obvious membraniform sign.Some myomas showed the feeding artery from uterus.Ovarian fibroma demonstrated hyper-enhancement at the periphery portion and hypoenhancement inside.Conclusions The SM and ovarian myomas showed different enhancement patterns,which may provide us some exact information in the differential diagnosis between the two diseases.