1.Evaluate the carotid artery stiffness of acquired immune deficiency syndrome patients by ultrasound quantitive artery stiffness technique
Haohui, ZHU ; Jianjun, YUAN ; Yisa, WANG ; Fan, GAO ; Xiao, WANG ; Changhuan, WEI ; Jiyun, CHEN ; Xiaohui, FAN
Chinese Journal of Medical Ultrasound (Electronic Edition) 2015;(7):541-544
Objetive To evaluate the carotid artery stiffness of acquired immune deficiency syndrome (AIDS) and analyze the mechanism and influence factors. Methods Fifty cases of AIDS patients and Fifty healthy people were enrolled in this study according to the principles of randomize and control. Quantitive inter-media thickness (QIMT) and quantitive artery stiffness (QAS) technique were employed to evaluate the inter-media thickness (IMT) and stiffness of right carotid artery. The parameters included IMT, compliance coefficent (CC), stiffness β (β), and pulse wave velocity (PWV). Unpaired t test was used to compare the parameters between two groups, and Pearson correlation analysis was used for linear correlation analysis. Results There were no statistically difference of carotid artery IMT between two groups [(0.569±0.095) mm vs (0.512±0.114) mm, P>0.05]. There was statistically difference of stiffness parameters (CC,β, PWV) between two groups [(0.59±0.21) mm2/kPa vs (1.04±0.41) mm2/kPa, 13.01±6.10 vs 8.14±1.37, (8.70±1.65) m/s vs (6.81±1.37) m/s, all P<0.05]. There was statistically signification association between HIV-infection time and CC,β, PWV ( r value was-0.575, 0.380, 0.417, all P<0.05 ), but there was no association between HIV-infection time and IMT( r value was 0.191, P>0.05 ). There was no statistically signification association between IMT, CC,β, PWV and CD4+, CD8+T cell count (r was 0.000, 0.012,-0.093,-0.097, 0.096, 0.012, 0.056, 0.024, all P>0.05). Conclusion The carotid artery stiffness of AIDS patients is reduced. HIV may play a role in the development of artery stiffness in AIDS patients.
2.Role of spinal c-Jun N-terminal kinase signaling pathway in incisional pain in rats
Haijiao ZHOU ; Peng LIU ; Yisa SHI ; Yuan TAN ; Jia LIU ; Wei ZHANG ; Jing WANG ; Jinglin MA
Chinese Journal of Anesthesiology 2015;(12):1463-1465
Objective To evaluate the role of spinal c?Jun N?terminal kinase ( JNK ) signaling pathway in incisional pain in rats. Methods Sixty?three adult male Sprague?Dawley rats, weighing 200-250 g, were randomly divided into 3 groups ( n=21 each) using a random number table: incisional pain group ( IP group) , dimethyl sulfoxide ( DMSO) group, and JNK inhibitor SP600125 group ( SP group) . A 1?cm longitudinal incision was made through skin, fascia and muscle of the plantar aspect of the hindpaw in anesthetized rats. In group DMSO, 10% DMSO 10 μl was injected intrathecally at 30 min before surgery. In group SP, SP600125 25 μg (in 10 μl of 10% DMSO) was injected intrathecally at 30 min before sur?gery. Six rats in each group were sacrificed, and the mechanical paw withdrawal threshold ( MWT) and thermal paw withdrawal latency ( TWL) were measured at 24 h before establishment of the model and 2, 6, 24, 48 and 72 h after establishment of the model. After measurement of the pain threshold at 24 h before establishment of the model and 6, 24, 48 and 72 h after establishment of the model, the lumbar segment of the spinal cord was removed for determination of the expression of phosphorylated JNK ( p?JNK) by im?munofluorescence. Results The MWT was significantly lower, the TWL was shorter, and the expression of p?JNK was lower at each time point after establishment of the model than at 24 h before establishment of the model in group IP (P<0?05). Compared with group IP, the MWT was significantly increased, the TWL was prolonged, and the expression of p?JNK was down?regulated at each time point after establishment of the model in group SP ( P<0?05) , and no significant change was found in the parameters mentioned a?bove in group DMSO ( P>0?05) . Conclusion Spinal JNK signaling pathway is involved in the develop?ment and maintenance of incisional pain in rats.
3.Application of tissue synchronization imaging by real-time thriplane echocardiography in cardiac resynchronization therapy
Changhua WEI ; Yisa WANG ; Haohui ZHU ; Jiyun CHEN ; Fan GAO ; Xuezheng QU ; Jianjun YUAN
Chinese Journal of Ultrasonography 2015;(7):553-557
Objective To investigate the applicable value of tissue synchronization imaging (TSI)by real-time thriplane echocardiography (RT3PE)in cardiac resynchronization therapy (CRT).Methods Twenty-four patients with heart failure scheduled for CRT and 24 healthy controls were enrolled.Two dimensional echocardiography was performed to get the left ventricular internal diameter at end-diastole and end-systole(LVIDd,LVIDs ),left ventricular ejection fraction (LVEF ),velocity time integral of left ventricular outflow tract flow (VTILVOT ).The RT3PE TSI was performed to measure the time to peak systolic velocities(Tp)of left ventricle basal and middle segments(12 segments),software will automatically calculate the maximal difierence (12-Tp-DIF)and standard deviation (12-Tp-SD)of Tp in 12 segment. Identity the segment where wall motion most delay and to guide electrode placement.AV and VV interval optimization were performed under guidance of TSI after 1 month of CRT.Results In before CRT,after CRT,after optimization and control group,LVIDd,Tp,LVIDs,12-Tp-DIF and 12-Tp-SD were decreased in the order,LVEF and VTILVOT were increased in the order.There were significant difference between the groups(all P < 0.05 ).TSI showed that left ventricular systolic dyssynchrony was present in all patients before CRT.The most delay segment and electrode location was consistent.There were close correlation between 12-Tp-DIF and LVEF (r =-0.70,P =0.000),between 12-Tp-SD and LVEF(r =-0.73,P =0.000).Conclusions Left ventricular systolic synchronicity can be evaluated accurately and intuitively using TSI by RT3PE.It has important clinical significance in prospectively select patients for CRT,help to guide electrode placement and to optimize device programming.
4.Effects of different doses of dexmedetomidine on perioperative inflammatory responses in patients undergoing one-lung ventilation
Rongzhi ZHANG ; Yisa SHI ; Yamin ZHANG ; Zhilong LIU ; Jianqin XIE ; Shubao WANG ; Xu XU
Chinese Journal of Anesthesiology 2014;34(z1):14-17
Objective To investigate the effects of different doses of dexmedetomidine on perioperative inflammatory responses in patients undergoing one-lung ventilation (OLV).Methods Thirty-six ASA T or Ⅱ patients (aged 43-72 years and weighing 50-78 kg) scheduled for esophagectomy were randomly divided into three groups (n =12 each):control group (group C),low dose dexmedetomidine group (group D1) and high dose dexmedetomidine group (group D2).Dexmedetomidine 1 μg/kg was infused intravenously 10 minutes before anesthesia induction,then infused at a rate of 0.2 μg· kg-1 · h-1 (group D1) or 0.5 μg· kg-1· h-1 (group D2) until 30 minutes before the end of operation.Group C received the equal volume of normal saline.Blood samples were collected before anesthesia induction (T0),immediately before OLV (T1),30 minutes after OLV (T2),90 minutes after OLV (T3),30 minutes after lung inflation (T4) and 2 hours after operation (T5) for monitoring serumlevels of tumor necrosis factor-alpha (TNF-α) and interleukin-8 (IL-8).Results Compared with T0,serum levels of TNF-α and IL-8 significantly increased at T3 and T5 in all the three groups (P < 0.05).Compared with group C,serum levels of TNF-α and IL-8 significantly decreased at T3 and T5 in group D2 (P < 0.05).There was no significant difference in the indexes mentioned above between group C and group D1 (P > 0.05).Conclusion Dexmedetomidine 1 μg/kg given before anesthesia induction and then infused at the rate of 0.5 μg· kg-1 ·h-1 during operation can reduce inflammatory responses in patients undergoing OLV.
5.Application progress on thoracic paravertebral nerve block in pediatric perioperative analgesia
Yuying MA ; Yisa SHI ; Yaqin WANG ; Qingyang YAN ; Xuelei JIN
The Journal of Clinical Anesthesiology 2024;40(1):80-84
Thoracic paravertebral nerve block(TPVB)is a regional anesthesia technique that pro-vides ipsilateral somatosensory,motor and sympathetic nerves block segmentally by injecting local anesthetics in the paravertebral space.In recent years,there has been an increasing number of studies on the use of TPVB technique for anesthesia and analgesia in pediatric thoracic and upper abdominal surgery,showing good perioperative analgesic efficacy.This article intends to provide a review of the current applica-tion and progress of TPVB technique for pediatric perioperative analgesia in terms of medication regimens,drug diffusion routes,block methods,clinical application,and complications.
6.Application of non-invasive left ventricular pressure-strain curve in evaluating left ventricular myocardial work in hemodialysis patients
Kaikai SHEN ; Haohui ZHU ; Xiao DING ; Rui XU ; Yisa WANG ; Jianjun YUAN
Chinese Journal of Ultrasonography 2020;29(6):505-510
Objective:The evaluate left ventricular myocardial work in maintenance hemodialysis (MHD) patients by non-invasive left ventricular pressure strain curve.Methods:Forty-eight patients undergoing maintenance hemodialysis were selected as the MHD group, and 33 healthy subjects were selected as the control group from Apr to Oct 2019 in Henan Provincial People′s Hospital. The differences of general clinical data, basic parameters of two-dimensional ultrasound including left ventricular end-diastolic diameter (LVDd), left ventricular end-systolic diameter (LVDs), left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), stroke volume (SV), diastolic interventricular septal thickness (IVSd), left ventricular diastolic posterior wall thickness (LVPWd), left ventricular diastolic mass (LVDm), left ventricular systolic mass (LVSm), late diastolic tissue velocity (a′), early diastolic peak velocity/early diastolic tissue velocity (E/e′), A peak and cardiac output (CO), peak strain dispersion (PSD), and global work index (GWI), global work efficiency (GWE), global constructive work (GCW), global wasted work (GWW) and global long-axis strain (GLS) between two groups were compared, and the correlation between myocardial work parameters and conventional cardiac parameters was analyzed.Results:①In terms of comparison, LVDd, LVDs, LVEDV, LVESV, SV, IVSd, LVPWd, LVDm, LVSm, systolic blood pressure (SBP), diastolic blood pressure (DBP), a′, E/e′. A peak and CO of the MHD group were greater than those in the control group (all P<0.05), and e′ of the MHD group was lower ( P<0.05). ②In terms of comparison, PSD and GWW of the MHD group were greater than those of the control group (all P<0.05), while GLS and GWE of the MHD group was lower (all P<0.05). There were no statistically significant differences in GCW and GWI between two groups(all P>0.05). ③GWI was positively correlated with SBP, DBP and left ventricular ejection fraction (LVEF)( r1=0.442, P1=0.030; r2=0.477, P2=0.019; r3=0.431, P3=0.040), and negatively correlated with GLS and LVDs( r1=-0.576, P1=0.003; r2=-0.404, P2=0.050). GWW was positively correlated with GLS and PSD( r1=0.584, P1=0.003; r2=0.564, P2=0.004). GWE was positively correlated with LVEF( r=0.424, P=0.044), and negatively correlated with LVEDV, LVESV, PSD, GLS and LVDm( r1=-0.444, P1=0.034; r2=-0.490, P2=0.018; r3=-0.721, P3<0.001; r4=-0.738, P4<0.001; r5=-0.442, P5=0.035). GCW was positively correlated with LVEF and DBP( r1=0.494, P1=0.017; r2=0431, P2=0.035), and negatively correlated with GLS and LVDs( r1=-0.630, P1=0.001; r2=-0.419, P2=0.042). Conclusions:The non-invasive left ventricular pressure-strain curve combines blood pressure and strain. Compared with the GLS, it can accurately assess left ventricular myocardial work in maintenance hemodialysis patients and predict potential left ventricular function changes in maintenance hemodialysis patients.
7.Analgestic efficacy of intermittent boluses for adductor canal block after total knee arthroplasty
Fengjiao LU ; Hongli SUN ; Shuangyin ZHANG ; Kai ZHANG ; Yingbin WANG ; Yisa SHI
The Journal of Clinical Anesthesiology 2018;34(5):441-444
Objective To compare two different regimens of ultrasound-guided Continuous ad-ductor canal block (CACB)for postoperative analgesia and early ambulation after total knee arthro-plasty (TKA).Methods Sixty-seven patients scheduled for unilateral TKA undergoing spinal anes-thesia,13 males and 54 females,aged 18-85 years,BMI 18-30 kg/m2,ASA physical status Ⅰ-Ⅲ, were randomly divided into the continuous infusion group A (n=34)and the intermittent boluses group B (n=33).After the operations,ultrasound-guided CACB were administered and 20 ml of 0.2% ropivacaine was given as the loading dose.From then on,patients in both groups used electronic analgesic pumps containing 240 ml of 0.2% ropivacaine for postoperative analgesia.5 ml/h of 0.2% ropivacaine was continuously infused for 48 hours in the group A.5 ml of 0.2% ropivacaine was automated injected every 60 minutes in the group B.All infusion pumps were setted at a bolus dose of 5 ml,with a lock time of 30 minutes.The total consumptions of analgestic pum solution and dezoine, quadriceps muscle strength, active range of knee flexion, ambulation distance and occurrences of adverse reactions such as nausea and vomiting,dizziness,drowsiness,extravasating and errhysis were recorded at different time points postoperatively.Results The total consumptions of analgestic pum solution at 12,24 h postoperatively of group B were significantly reduced than that of group A (P<0.05).The 48 h total dezoine consumption of group B was significantly reduced than group A (P<0.05).Active range of knee flexion at 24,48 h and ambulation distance at 48,72 h of group B were significantly higher than group A (P<0.05).There was no statistical difference in quadriceps muscle strength between group A and group B.The incidence of nausea and vomiting in group A was significantly higher than that in group B,and there were no statistical difference in other adverse reactions between group A and group B.Conclusion Compared with the continuous infusion group,the intermittent bolus group for CACB after TKA can provide better analgesic effect and de-crease opioid use postoperatively,with little effect on motor nerve,promoting early ambulation.
8.Evaluation of changes in left atrial volume and function in patients with early diabetic nephropathy by four-dimensional auto left atrial quantification
Yisa WANG ; Haohui ZHU ; Xijun ZHANG ; Limin ZHU ; Changhua WEI ; Jiyun CHEN ; Kaikai SHEN ; Jing TIAN ; Jianjun YUAN
Chinese Journal of Ultrasonography 2022;31(5):407-413
Objective:To explore the changes of left atrial volume and function in patients with early diabetic nephropathy by four-dimensional auto left atrial quantification (4D Auto LAQ).Methods:Forty patients with early diabetic nephropathy (early diabetic nephropathy group), 40 patients with type 2 diabetes (diabetes group) in Henan Provincial People′s Hospital from March 2020 to April 2021 were selected, and 36 healthy volunteers (control group) were collected during the same period. The parameters of conventional echocardiography were measured, and the four-dimensional volume probe was used to obtain the complete left atrial volume image in 5 cardiac cycles. The 4D Auto LAQ software on the EchoPAC workstation was used for analysis to obtain the left atrial volume and strain indicators: left atrial (LA) maximum volume (LAVmax), left atrial minimum volume (LAVmin), pre-systolic volume (LAVpreA), left atrial volume index (LAVImax), left atrial emptying volume (LAEV), left atrial emptying fraction (LAEF), and long axis and circumferential strains in left atrial reserve phase, pipeline phase and systolic phase (LASr, LASr-c; LAScd, LAScd-c; LASct, LASct-c). The differences of these parameters among 3 groups were analyzed.Results:There were no significant differences in interventricular septum end-diastolic thickness(IVSd), left ventricular posterior wall end-diastolic thickness(LVPWd), left ventricular end-diastolic dimension(LVIDd), left ventricular ejection fraction(LVEF), and E/A (ration of early to late diastolic peak flow velocity of mitral orifice) among 3 groups (all P>0.05), and left atrial diameter(LAD), relative wall thickness(RWT), and E/e′ (ration of early diastolic peak flow velocity of mitral orifice to early diastolic velocity of lateral mitral annulus) among 3 groups were significantly different (all P<0.05). Further pairwise comparison results showed that LAD was only significantly different between the early diabetic nephropathy group and control group ( P=0.001 2), and the differences in RWT and E/e′ were statistically significant among 3 groups (all P<0.05). There were no significant differences in LAEV, LAScd-c, and LASct-c among 3 groups (all P>0.05), and LAVmin, LAVmax, LAVpreA, LAVImax, LAEF, LASr, LAScd, LASct, and LASr-c among the 3 groups were significantly different (all P<0.05). The pairwise comparison showed that, compared with the control group and the diabetes group, LAVmin, AVpreA, and LAVImax in the early diabetic nephropathy group were increased, and LAEF, LAScd, LASct, and LASr-c were decreased (all P<0.05). Compared with the control group, LAVmax, LAVImax and LASct in the diabetes group were increased, and LAEF, LAScd, and LASr-c were decreased (all P<0.05). Conclusions:4D Auto LAQ technology can quantitatively evaluate the changes in left atrium volume and function in patients with early diabetic nephropathy. Patients with early diabetic nephropathy have an increase in left atrium volume and a decrease in strain value.
9.Application of pressure-strain loop in evaluating left ventricular myocardial function in hypertrophic cardiomyopathy
Miao ZHANG ; Jianjun YUAN ; Yisa WANG ; Haohui ZHU ; Changhua WEI ; Xiao DING ; Siliang LI ; Shuai LI ; Wen GUO ; Huifang LIU
Chinese Journal of Ultrasonography 2020;29(7):576-580
Objective:To explore the value of pressure-strain loop (PSL) for non-invasive quantitative assessment of left ventricular myocardial work index (GWI), global work efficiency (GWE), global constructive work (GCW), global wasted work (GWW) in the evaluation of left ventricular myocardial work in patients with hypertrophic cardiomyopathy (HCM).Methods:Thirty-one HCM patients (HCM group) and 36 healthy volunteers (control group) from December 2018 to September 2019 in Henan Provincial People′s Hospital were selected. Relevant clinical data were collected, left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDd), left ventricular end systolic diameter (LVEDs), left atrial diameter (LAD), the maximum wall thickness (MWT), left ventricular mass index (LVMI), the global longitudinal strain (GLS), the peak strain dispersion(PSD) and GWI, GWE, GCW and GWW between the two groups were compared.Results:Compared with the control group, MWT, LAD, E/e′, LVMI in HCM group were significantly increased (all P<0.05); left ventricular myocardial functional parameters of GLS, GWI, GWE, GCW were significantly decreased, and GWW and PSD were significantly increased (all P<0.05). Left ventricular GLS, PSD and GWI, GCW, GWW, GWE have better repeatability within the observer and between observers. ICC within the observer were 0.852, 0.707, 0.917, 0.955, 0.675, 0.618, respectively. And their ICC between observers were 0.837, 0.631, 0.927, 0.944, 0.555, 0.670, respectively. Correlation analysis showed that GLS was positively correlated with GWI, GWE, and GCW ( r=0.765, 0.737, 0.815; all P<0.001), and negatively correlated with GWW and PSD ( r=-0.517, -0.606; all P<0.001). Conclusions:The left ventricular GWI, GWE and GCW decreased in HCM patients, while the GWW increased. PSL can evaluate the damage of left ventricular myocardial work in HCM patients.