1.Early and midterm results of Ebstein′s anomaly with the treatment:the cone reconstruction for the tricuspid valve
Yiqiu CAO ; Jie XING ; Ruzheng LI ; Hong ZHANG
The Journal of Practical Medicine 2017;33(12):1948-1952
Objective To evaluate the early and midterm effect by retrospective analysis of the cone reconstruction in Ebstein′s anomaly. Methods From January 2012 through June 2016,16 patients with Ebstein′s anomaly underwent the cone reconstruction in our hospital. There were 7 males and 9 females at mean age(28.21 ± 11.88)years,including 12 patients of Carpentier B type,4 patients of Carpentier C type. There were 9 patients in New York Heart Association(NYHA)functional class Ⅲ,5 patients in NYHA functional class Ⅳand the others in NYHA functional class Ⅱ. All patients had Tricuspid insufficiency ,including 2 patients with Grade 2 ,10 patients with Grade 3 and 4 patients with Grade 4. All patients were followed up over a period of 6 to 51 months (mean:24.36 ± 10.71). By comparing the details of pre-operation with post-operation and post-operation with current stage,we analyze the outcomes of early and midterm effects. Results All patients are well survived. There were one patient recovering from the low cardiac output syndrome with adding the strength of the positive inotropic drug in the first day after operation ,and one patient recovering from bigeminy of ventricular prematurebeat with the aid of amiodarone and lidocaine the third day after operation. The remaining patients recovered smoothly. Early post-operative echocardiograms showed good right ventricular morphology and reduction in tricuspid regurgitation grade from(3.13 ± 0.62)to(1.75 ± 0.45)(P<0.001)with the functional class improved from(3.19 ± 0.66)to(2.00 ± 0.52)(P<0.001). After mean follow-up of(24.36 ± 10.71)months,the situation is improving furtherly with the tricuspid regurgitation grade reducing to(1.31 ± 0.48)(P=0.016)and the functional class rising to(1.50 ± 0.52) (P = 0.031). Conclusions This surgical technique for Ebstein′s anomaly can improve the function of tricuspid valve and the right ventricular morphology. It showed a satisfactory performance in the early and midterm results by enhancing the Cardiac function and life quality. But indications should be strictly grasped and more experiences need to be accumulated. Long-term effect need to be furtherly explored.
2.Application of 3D printing technology in the personalized surgery of right ventricular double outlet
Zhu DONG ; Ben ZHANG ; Yiqiu CAO ; Bo YANG ; Ying LIU ; Yanchun ZHENG ; Xiaowu WANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2021;28(04):441-446
Objective To evaluate the clinical value of three-dimensional (3D) printing model in accurate and minimally invasive treatment of double outlet right ventricle (DORV). Methods From August 2018 to August 2019, 35 patients (22 males and 13 females) with DORV aged from 5 months to 17 years were included in the study. Their mean weight was 21.35±8.48 kg. Ten patients who received operations guided by 3D printing model were allocated to a 3D printing model group, and the other 25 patients who received operations without guidance by 3D printing model were allocated to a non-3D printing model group. Preoperative transthoracic echocardiography and CT angiography were performed to observe the location and diameter of ventricular septal defect (VSD), and to confirm the relationship between VSD and double arteries. Results The McGoon index of patients in the 3D printing model group was 1.91±0.70. There was no statistical difference in the size of VSD (13.20±4.57 mm vs. 13.40±5.04 mm, t=−0.612, P=0.555), diameter of the ascending aorta (17.10±2.92 mm vs. 16.90±3.51 mm, t=0.514, P=0.619) or diameter of pulmonary trunk (12.50± 5.23 mm vs. 12.90±4.63 mm, t=−1.246, P=0.244) between CT and 3D printing model measurements. The Pearson correlation coefficients were 0.982, 0.943 and 0.975, respectively. The operation time, endotracheal intubation time, ICU stay time and hospital stay time in the 3D printing model group were all shorter than those in the non-3D printing model group (P<0.05). Conclusion The relationship between VSD and aorta and pulmonary artery can be observed from a 3D perspective by 3D printing technology, which can guide the preoperative surgical plans, assist physicians to make reasonable and effective decisions, shorten intraoperative exploration time and operation time, and decrease the surgery-related risks.
3.Preparation technology of platelet-rich-plasma lysate combined with hyaluronic acid microneedles and wound healing effect
Zhengxin SUO ; Ye CAO ; Shifan ZHENG ; Yiqiu GAO ; Yingcan XU ; Hong WANG ; Jiaxin LIU ; Rui ZHONG
Chinese Journal of Blood Transfusion 2022;35(5):508-514
【Objective】 To investigate the application prospect of platelet-rich plasma lysate (PL) microneedles in the treatment of wound healing by optimizing the preparation process and evaluating the activity of platelet growth factor. 【Methods】 Firstly, hyaluronic acid (HA) was used as needle matrix material, and the concentration of HA was preliminarily determined by investigating the fluidity of HA solution, shape of needle, pressure change performance and puncture performance.Combined with the results of HA dissolution in PL, mechanical properties of PL microneedles and skin puncture, the preparation process of platelet-rich plasma lysis microneedles (PLMN) was optimized to investigate the growth factor activity of PLMN and evaluate the effect of PLMN on wound healing in rats. 【Results】 When the concentration of HA was 30 mg/mL, the solution had good fluidity.The HA microneedles could pierce three layers of sealing film, with the puncture rate at 70%, and the solution had good mechanical properties.When HA was dissolved in PL at a concentration of 30 mg/mL at 4℃, the solution had no crystallization and was with good fluidity.The prepared PLMN showed good needle shape and no bending under HD microscope and scanning electron microscope.In vitro transdermal simulation results showed that PLMN could penetrate 4 layers of sealing membrane, and the puncture rate of the first three layers was more than 85%.In vivo lysis experiment showed that PLMNs could be completely dissolved within 10 min after being inserted into the body.Forty minutes later, the micropores left after the insertion of the microneedle were almost closed, without redness, swelling, erythema and other adverse reactions.In vitro and in vivo transdermal experiments showed that clear blue holes were visible after PLMNs penetrated the skin stain, indicating that the microneedles could pierce the skin barrier.Growth factor detection results showed that the content of platelet-derived growth factor (PDGF-BB) and transforming growth factor (TGFβ1) in platelet lysate were (17.67±1.23) ng/mL and (105.95±2.16) ng/mL, respectively.After PLMNs were prepared and stored at room temperature for 1 week, the content of PDGF-BB(ng/mL) and TGFβ1(ng/mL) were 15.48±2.12 and 56.26±1.53, respectively.Compared with PL(vs 17.67±1.23 and 105.95±2.16), the content of PDGF-BB and TGFβ1 decreased, but still maintained the activity of growth factors.The results of wound healing experiment in rats showed that the wound healing rate (%) of PLMN group on the third day was significantly different from that of the control group(52.51±6.15 vs 33.31±3.60, P<0.05). 【Conclusion】 The PLMN prepared in this experiment has good mechanical properties and can successfully pierce the skin cuticle.It can also maintain the activity of growth factors, and has a good effect on wound healing in rats, which provides a new idea for minimally invasive treatment in the field of tissue repair.
4.Effect of PolyCHb oxygen carrier on partial coagulation indexes in vitro
Jiawei LI ; Shen LI ; Wentao ZHOU ; Yiqiu GAO ; Huan WANG ; Zhengxin SUO ; Hong WANG ; Ye CAO ; Jiaxin LIU
Chinese Journal of Blood Transfusion 2021;34(4):339-342
【Objective】 To compare the similarities and differences of polymerized human cord hemoglobin (PolyCHb) and free hemoglobin (FHb) on partial coagulation indexes in vitro, so as to analyze the effect of PolyCHb on coagulation dysfunction. 【Methods】 Using normal saline, two concentrations of FHb and PolyCHb and 36% methemoglobin-containing PolyCHb to mix with fresh whole blood or plasma-rich plasma (PRP) in equal proportions, and incubate at 37°C for 30 minutes to detect prothrombin time (PT), activated partial thromboplastin time (APTT), coagulation factor Ⅱactivity (FⅡ∶C), coagulation factor Ⅴactivity (FⅤ∶C), coagulation factor Ⅷactivity (FⅧ∶C), coagulation factor Ⅸactivity (FⅨ∶C), von Willebrand factor (vWF) and platelet P-selectin (CD62P). 【Results】 1) NaCl group: PT(22.68±1.76) s; APTT(59.58±7.52) s; FⅡ∶C(45.91±3.27) %; FⅤ∶C(30.86±4.43) %; FⅧ∶C(41.32±12.94) %; FⅨ∶C(23.96±5.10) %; vWF (2.14±0.54) mg/L; CD62P(7.44±4.47) %. This group kept as a diluted control. 2) 2% FHb group compared with 7% FHb group: FⅧ∶C (42.16±12.31) %vs (56.64±12.22 ) % (P<0.05). No significant difference was found in other indexes (P>0.05). 3) There is no significant difference between 2% PolyCHb group and 7% PolyCHb group (P>0.05). 4) There is no significant difference between 2% FHb group and 2% PolyCHb group (P>0.05). 5) 7% FHb group compared with 7% PolyCHb group: PT(23.31±1.34)s vs (21.97±1.56)s (P<0.05); APTT(50.12±5.72)s vs (55.43±5.43)s (P<0.05); FⅧ∶C (56.64±12.22) %vs (42.37±13.00)% (P<0.05); vWF (1.41±0.30) mg/L vs (2.25±0.41) mg/L (P< 0.05). No significant difference was found in other indexes (P>0.05). 6) 7% PolyCHb group Compared with Met-PolyCHb group: APTT(55.43±5.43) s vs (46.33±4.86)s (P<0.05); FⅧ∶C (42.37±13) %vs (60.51±10.16) % (P<0.05). No significant difference was found in other indexes (P>0.05). 【Conclusion】 The effect of PolyCHb on coagulation markers is different from FHb. At the concentration of this study, PolyCHb will not cause coagulation disorders. However, if the methemoglobin (MetHb) content is too high, it will activate the intrinsic coagulation pathway.