1.Mechanism of RING finger protein 34 involved in innate immunity:a preliminary study
Yongjie ZHU ; Pingping ZHANG ; Pengyu ZHOU ; Penghao WANG ; Jiankang CHEN ; Yinyin TIAN ; Xiang HE ; Hui ZHONG
Military Medical Sciences 2017;41(1):43-47,61
Objective To study the mechanism of RING finger protein 34 ( RNF34 ) involved in innate immunity . Methods Recombinant PCR was used and transient expression of the plasmid was achieved in HEK 293T cells.The cells were stimulated with Sendai virus ( SeV) or N-RIG-Ⅰfor the indicated time while luciferase activity was observed using the dual-luciferase reporter assay kit .Results We constructed the plasmid pcDNA 3-Flag-RNF34 and its three mutations .The study found that when stimulated by SeV , RNF34 could inhibit the activity of NF-κB and IFN-βmore significantly than RNF34-ΔFYVE, RNF34-ΔCID and RNF34-ΔRING.We also found that RNF 34 and its three mutants had similar inhibitory effect when the activation of NF-κB and IFN-βwas stimulated by the N-RIG-Ⅰ.Conclusion RNF34 negatively regulates innate immunity by acting on the RIG-Ⅰ-MAVS signaling pathway .
2.A study on diagnostic performance of 3.0 T non-contrast-enhanced Dixon water-fat separation compressed SENSE whole-heart coronary MR angiography
Hongfei LU ; Di TIAN ; Shihai ZHAO ; Yinyin CHEN ; Jianying MA ; Mengsu ZENG ; Hang JIN
Chinese Journal of Radiology 2022;56(10):1051-1057
Objective:To evaluate the diagnostic performance of non-contrast-enhanced Dixon water-fat separation Compressed SENSE (CS-SENSE) whole-heart coronary magnetic resonance angiography (CMRA) at 3.0 T on patients with suspected coronary artery disease (CAD).Method:The study complied with the Declaration of Helsinki. Local ethics committee approved this study and written informed consent was obtained from each patient. In this prospective study, from March 2021 to September 2021, 53 consecutive participants with suspected CAD who were scheduled for X-ray coronary angiography (CAG) were prospectively recruited in Zhongshan Hospital. CMRA was performed with a 3.0 T scanner without contrast agent enhancement during free breathing with Dixon water-fat separation and CS-SENSE methods. The accuracy of CMRA for detecting a ≥ 50% reduction in diameter was determined using CAG as the reference method.Results:Acquisition of whole-heart CMRA images was successfully performed in 46 (86.8%) of 53 patients with an average imaging time of (7.8±1.8) min. The sensitivity, specificity, positive predictive values, negative predictive values, and accuracy of CMRA according to a patient-based analysis were 95.8%(95%CI 78.9%-99.9%), 81.8%(95%CI 59.7%-94.8%), 85.2%(95%CI 66.3%-95.8%), 94.7%(95%CI 74.0%-99.9%), 89.1%(95%CI 76.4%-96.4%), respectively. The areas under the receiver-operator characteristic curve (AUC) from CMRA images according to patient-, vessel-and segment-based analyses were 0.876(95%CI 0.745-0.955), 0.880(95%CI 0.814-0.929), 0.903(95%CI 0.877-0.926), respectively.Conclusion:3.0 T non-contrast-enhanced Dixon water-fat separation CS-SENSE whole-heart CMRA is a promising technique to detect clinically significant coronary stenosis on patients with suspected CAD.
3.Recent progress in hypothyroidism after adjuvant radiotherapy for breast cancer
Yinyin YANG ; Siyuan LI ; Difan WANG ; Shang CAI ; Ye TIAN
Chinese Journal of Radiological Medicine and Protection 2023;43(11):934-938
Hypothyroidism (HT) can arise as a complication of radiotherapy for breast cancer. Despite having a significant impact on patients′ quality of life, HT had always been overlooked by radiotherapists in the past. In recent years, many studies highlighting the protection of the thyroid in the process of radiotherapy for breast cancer have been conducted, achieving valuable conclusion. These studies can serve as a guide for radiotherapists to limit the dose to the thyroid during radiotherapy, thus reducing the incidence of HT.