1.Dual-source CT coronary angiography in patients with premature heart-beats:initial experience
Yining WANG ; Zhuhua ZHANG ; Lingyan KONG ; Lan SONG ; Wenbin MU ; Yun WANG ; Zhengyu JIN
Chinese Journal of Radiology 2008;42(9):907-910
Objective To evaluate the feasibility of dual-source computed tomography(DSCT)coronary angiography in a population with premature heart-beats.Methods Seventy patients with suspected coronary artery disease and premature heart-beats were routinely imaged on a DSCT scanner(Somatom Definition,Siemens AG,Germany).The images were reconstructed before and after ECG editing.Two readers independently assessed image quality of all coronary segments using a four-point grading scale from excellent(1)to non-assessable(4).The results ofthe two groups were compared with a paired t-test,and a P value of less than 0.05 Was considered significant.Results The mean heart rate during examination ranged from 49 to 111 bpm[mean(70.7±12.4)bpm].Twenty-eight of 70 patients with relatively small variability of the heart rate[(41.0±18.4)bpm]got diagnostic image quality without ECG editing.In other 42 patients with larger variability of the heart rate[(71.4±28.7)bpm],the meal image quality scores were 2.09±1.27 and 1.50±0.79 before and after ECG editing,there Was a significant difference(t=13.764,P<0.01).The proportion of non-assessable segments Was reduced from 24.8%(154/620)to 3.4%(21/620)through ECG editing(X2=121.846,P<0.01).Finally,the diagnostic image accounted 98.0%(1014/1035)in all segments of 70 patients.Conclusion DSCT can provide diagnostic images for patients with premature heart-beats.The image quality in patients with larger variability of the heart rate can be significantly improved through ECG editing.
2.Bioinformatics study on the hub genes of glomerulopathy in type 2 diabetic nephropathy
Jiao KONG ; Chuanxin LIU ; Baonan MA ; Yining ZHANG ; Jiali ZHOU ; Qian WANG ; Jie ZHANG ; Jianmei HUANG
Chinese Journal of Endocrinology and Metabolism 2021;37(4):274-280
Objective:To identify the hub differentially expressed genes(DEGs)of glomerular pathological changes and potential pathways in molecular process of type 2 diabetic nephropathy(DN)based on bioinformatics technology.Methods:The differentially expressed genes of Gene Expression Omnibus(GEO)dataset GSE96804 in DN and normal kidney tissues were analyzed by R 3.6.2 software. DEGs were further assessed by Gene Ontology(GO)function enrichment analysis and Kyoto Encyclopedia of Genes and Genomes(KEGG)signal pathway analysis. Subsequently, the hub genes and their associated pathways were analyzed using String 11.0 and Cytoscape 3.7.2 software.Results:A total of 168 DEGs were obtained in the dataset. Among them, seven hub genes were identified, including ALB, FN1, EGF, PTGS2, PLG, KDR, and LOX. Three hub genes, ALB, EGF, PLG, exerted a direct action on glomerulus. GO enrichment analysis of DEGs was mainly manifested in extracellular matrix organization, extracellular structure organization, platelet degranulation and other biological processes, extracellular matrix, secretory granule lumen, platelet alpha granule and other cell components, chaperone binding, copper ion binding, antioxidant activity, and other molecular functions. DEGs mainly regulated metabolic process, which was related to fatty acid degradation signal pathway, exogenous substance metabolism related to CYP enzyme and drug metabolism signal pathway.Conclusion:A bioinformatics analysis of DN from the perspective of glomerulopathy is helpful to understand the potential molecular mechanism of DN and provide reference for further validation.
3.The impact of heart rate on image quality and reconstruction timing of dual-source CT coronary angiography
Yining WANG ; Zhengyu JIN ; Lingyan KONG ; Zhuhua ZHANG ; Lan SONG ; Shuyang ZHANG ; Songbai LIN ; Wenbin MOU ; Yun WANG ; Wenmin ZHAO
Chinese Journal of Radiology 2008;42(2):119-122
ObjectiveTo evaluate the impact of patient's heart rate(HR)on coronary CT angiography(CTA)image quality(IQ)and reconstruction timing in dual-source CT(DSCT).Methods Ninety-five patients with suspicion of coronary artery disease were examined with a DSCT scanner(Somatom Definition.Siemens)using 32×0.6 mm collimation.All patients were divided three groups according to the heart rate(HR):group 1,HR≤70 beats per minute(bpm),n=26;group 2,HR>70 bpm to≤90 bpm, n=37;group 3,HR>90 bpm,n=32. No beta-blockers were taken before CT scan.50-60 ml of nonionic contrast agent were injected with a rate of 5 ml/s. Images were reconstructed from 10%to 100% of the R-R interval using single-segment reconstruction. Two readers independently assessed IQ of all coronary segments using a 3-point scale from excellent(1)to non-assessable(3)for coronary segments and the relationshiD between IQ and the HR. ResuitsOverall mean IQ score was 1.31 ±0.55 for all patients with 1.08±0.27 for group 1,1.32±0.58 for group 2 and 1.47±0.61 for group 3. The IQ was better in the LAD than the RCA and LCX(P<0.01).Only 1.4%(19/1386)of coronary artery segments were considered non-assessable due to the motion artifacts.Optimal image quality of all coronary segments in 74 patients(77.9%)can be achieved with one reconstruction data set.The best IQ was predominately in diastote(88.5%)in group 1,while the best IQ was in systole(84.4%)in group 3. ConclusionsDSCT can achieve the optimal IQ with a wide range of HR using single-segment reconstruction. With the increasing of HR,the timing of data reconstruction for the best IQ shifts from mid-diastole to systole.
4.Mediating effect of blood glucose in the association between myosteatosis and complications in non-diabetic postoperative gastric cancer patients on supplemental parenteral nutrition
Ning LAN ; Yujie ZHOU ; Fuzhi JIAO ; Yining ZHAO ; Fei KONG ; Yanting LI ; Quanlin GUAN ; Wenzhen YUAN
Chinese Journal of Clinical Nutrition 2022;30(1):19-26
Objective:To explore the effects of myosteatosis and blood glucose (BG) on postoperative complications in non-diabetic gastric cancer patients receiving supplemental parenteral nutrition (SPN) after gastrectomy.Methods:Patients who underwent radical gastrectomy between March 2017 and June 2021 in the Department of Surgical Oncology, the First Hospital of Lanzhou University were included in this study. Various preoperative inflammatory and nutritional indicators, including skeletal muscle metrics at the third lumbar level on CT, were collected retrospectively. Postoperative BG within 3 days and complications within 30 days were monitored. Patients were divided into two groups according to the presence or absence of myosteatosis (assessed via skeletal muscle density [SMD]) and the differences in postoperative BG and complication incidence were compared. Mediation model was used to analyze the mediating effect of BG in the association between SMD and postoperative complications.Results:A total of 357 patients were included in the study. Compared with the 299(83.8%) patients without myosteatosis , the incidence of hyperglycemia, mean BG, maximal BG, and BG fluctuation while on SPN in the 58(16.2%) patients with myosteatosis were higher, and the comprehensive complication index (CCI) and the incidence of complication were higher ( P<0.05). More importantly, BG showed the mediation effect of -0.0892 in the effect of SMD on CCI ( P<0.05), with the effect size of 19.3%. Conclusion:Myosteatosis and postoperative hyperglycemia are associated with higher incidence of complications, and BG plays an intermediary role in the association between myosteatosis and CCI.
5.Coronary Artery Imaging in Patients with High Heart Rate by Dual-source CT:The Initial Experience
Zhuhua ZHANG ; Zhengyu JIN ; Shuyang ZHANG ; Songbai LIN ; Dongjing LI ; Lingyan KONG ; Yining WANG ; Lan SONG ; Yun WANG ; Wenmin ZHAO ; Linhui WANG ; Xiaona ZHANG ; Yunqing ZHANG ; Bing QI ; Kai XU ; Jixiang LIANG ; Haifeng ZHU ; Wenbin MOU ; Liren ZHANG ; Wenling ZHU ; Qi MIAO ; Qi FANG
Journal of Practical Radiology 2001;0(08):-
Objective To explore the scanning technique and image quality of coronary artery imaging with dual-source CT without oral Betaloc preparation in the patients with high heart rate.Methods 412 cases were undergone coronary imaging with dual-source CT (including plain and enhanced scans) ,among them,there were 30 cases with heart rate more than 100 bpm.Multi-planar reconstruction(MPR),maximum intensity projection(MIP) and volume rendering (VR) were performed using contrast-enhanced images.The image quality was classified into 3 grades, and coronary segments named according to AHA standard were evaluated.Results The average heart rate during enhanced scan in the 30 cases was (115.6?11.8)(101~139)bpm,the average breath hold time was (5.7?1.2) s.The best reconstruction phase was in the systolic phase. Altogether 424 coronary segments were evaluated, among them 93.9%(398/424)belonged to the first grade,5.0%(21/424)belonged to the second grade,and 1.2%(5/424) belonged to the third grade. Conclusion Without oral administration of Betaloc preparation, good coronary artery images can be obtained in the patients with high heart rate by dual-source CT.
6.A plateform for management of atrial fibrillation based on internet and medical concortium
Hui SHEN ; Zheng LI ; Xinhua WANG ; Long SHEN ; Zhichun GU ; Wei ZHANG ; Chi ZHANG ; Mangmang PAN ; Lingcong KONG ; Tian SHUANG ; Qian ZHAO ; Yining YANG ; Liqing ZHOU ; Jun PU
Chinese Journal of General Practitioners 2021;20(10):1100-1104
In order to provide efficient medical care to atrial fibrillation patients in the community, the Huamu Community Health Service Center in association with its medical consortium, Renji Hospital have developed a novel atrial fibrillation management system. With the collaboration of general practitioners and specialist team from the tertiary hospital, a special clinic for atrial fibrillation has been set up in the community health service center, which is based on the internet technology and the medical consortium platform. This article introduces the development of this novel system and the initial outcome of the measures, to provide a reference for the management of atrial fibrillation patients in the community.
7.Initial Experience of the Application of Third-generation Dual-source CT Scanner in High-pitch Angiography of Aorta.
Jixiang LIANG ; Lingyan KONG ; Zhengyu JIN ; Yun WANG ; Huadan XUE ; Yining WANG ; Daming ZHANG ; Jin CHEN
Acta Academiae Medicinae Sinicae 2017;39(1):68-73
Objective To evaluate the value of third-generation dual-source CT scanner in application of high-pitch aorta CT angiography(CTA). Methods Totally 59 patients clinically indicated for whole aorta angiography were divided into 2 groups using a simple random method:in group 1 there were 28 patients who underwent the examination on a third-generation dual-source CT device,with a collimation of 2×192×0.6 mm and a rotation time of 0.25 s;in group 2 there were 31 patients who underwent the examination on a second generation dual-source CT device,with a collimation of 2×128×0.6 mm and a rotation time of 0.28 s. Both groups were given the examination operated in dual-source high-pitch ECG-gating mode with a pitch of 3.0,a tube voltage of 100 kV,and automated tube current modulation using a reference tube current of 288 mA. A contrast material bolus of 45 ml with a flow of 4.5 ml/s followed by a 50 ml saline chaser in 5.0 ml/s was used. CTA scan was automatically started using a bolus tracking technique at the level of the original part of aorta after a trigger threshold of 100 HU was reached. The start delay was set to 6 s in both groups. Effective dose(ED),signal to noise ratio (SNR),contrast to noise ratio (CNR),and subjective diagnostic quality of both groups were evaluated. Results The mean ED were 19.44% lower (t=-3.989,P=0.000) in group 1 [(3.15±0.86)mSv] than in group 2 [(3.91±0.60)mSv]. These two groups showed no significant differences in SNR or CNR (all P >0.05). The subjective diagnostic quality values also showed no significant difference between two groups [(1.39±0.50)scores vs. (1.45±0.51)scores;W=814.5,P=0.651].Conclusion Compared with the second-generation dual-source CT scanner,the third-generation dual-source CT scanner in whole aorta CTA can remarkably reduce the radiation dose without affecting image quality.
Aorta
;
diagnostic imaging
;
Computed Tomography Angiography
;
methods
;
Humans
;
Radiation Dosage
;
Retrospective Studies
;
Signal-To-Noise Ratio
8.Initial Experience of the Application of Automated Tube Potential Selection Technique in High-pitch Dual-source CT Angiography of Whole Aorta Using Third-generation Dual-source CT Scanner.
Lingyan KONG ; Jixiang LIANG ; Huadan XUE ; Yining WANG ; Yun WANG ; Zhengyu JIN ; Daming ZHANG ; Jin CHEN
Acta Academiae Medicinae Sinicae 2017;39(1):62-67
Objective To evaluate the application of automated tube potential selection technique in high-pitch dual-source CT aortic angiography on a third-generation dual-source CT scanner. Methods Whole aorta angiography were indiated in 59 patients,who were divided into 2 groups using a simple random method:in group 1 there were 31 patients who underwent the examination with automated tube potential selection using a vascular setting with a preferred image quality of 288 mA/100 kV;in group 2 there were 28 patients who underwent the examination with a tube voltage of 100 kV and automated tube current modulation using a reference tube current of 288 mA. Both groups were scanned on a third generation dual-source CT device operated in dual-source high-pitch ECG-gating mode with a pitch of 3.0,collimation of 2×192×0.6 mm,and a rotation time of 0.25 s. Iterative reconstruction algorithm was used. For group 1,the volume and flow of contrast medium and chasing saline were adapted to the tube voltage. For group 2,a contrast material bolus of 45 ml with a flow of 4.5 ml/s followed by a 50 ml saline chaser at 5 ml/s was used. CTA scan was automatically started using a bolus tracking technique at the level of the original part of aorta after a trigger threshold of 100 HU was reached. The start delay was set to 6 s in both groups. Effective dose (ED),signal to noise ratio (SNR),contrast to noise ratio (CNR),and subjective diagnostic quality of both groups were evaluated. Results The mean ED were 21.3% lower (t=-3.099,P=0.000) in group 1 [(2.48±0.80) mSv] than in group 2 [(3.15±0.86) mSv]. Two groups showed no significant difference in attenuation,SD,SNR,or CNR at all evaluational parts of aorta (ascending aorta,aortic arch,diaphragmatic aorta,or iliac bifurcation)(all P>0.05). There was no significant difference in subjective diagnostic quality values of two groups [(1.41±0.50) scores vs. (1.39±0.50) scores;W=828.5,P=0.837]. Conclusion Compared with automated tube current modulation,the automated tube potential selection technique in aorta CT angiography on a third-generation dual-source CT can dramatically reduce radiation dose without affecting image quality.
Algorithms
;
Aorta
;
diagnostic imaging
;
Computed Tomography Angiography
;
methods
;
Humans
;
Radiation Dosage
;
Radiographic Image Interpretation, Computer-Assisted
;
Signal-To-Noise Ratio
9.Application of the Low-dose One-stop-shop Cardiac CT Protocol with Third-generation Dual-source CT.
Lu LIN ; Yining WANG ; Yan YI ; Jian CAO ; Lingyan KONG ; Hao QIAN ; Hongzhi ZHANG ; Wei WU ; Yun WANG ; Zhengyu JIN
Acta Academiae Medicinae Sinicae 2017;39(1):34-41
Objective To evaluate the feasibility of a low-dose one-stop-shop cardiac CT imaging protocol with third-generation dual-source CT (DSCT). Methods Totally 23 coronary artery disease (CAD) patients were prospectively enrolled between March to September in 2016. All patients underwent an ATP stress dynamic myocardial perfusion imaging (MPI) (data acquired prospectively ECG-triggered during end systole by table shuttle mode in 32 seconds) at 70 kV combined with prospectively ECG-triggered high-pitch coronary artery angiography (CCTA) on a third-generation DSCT system. Myocardial blood flow (MBF) was quantified and compared between perfusion normal and abnormal myocardial segments based on AHA-17-segment model. CCTA images were evaluated qualitatively based on SCCT-18-segment model and the effective dose(ED) was calculated. In patients with subsequent catheter coronary angiography (CCA) as reference,the diagnosis performance of MPI (for per-vessel ≥50% and ≥70% stenosis) and CCTA (for≥50% stenosis) were assessed. Results Of 23 patients who had completed the examination of ATP stress MPI plus CCTA,12 patients received follow-up CCA. At ATP stress MPI,77 segments (19.7%) in 13 patients (56.5%) had perfusion abnormalities. The MBF values of hypo-perfused myocardial segments decreased significantly compared with normal segments [(93±22)ml/(100 ml·min) vs. (147±27)ml/(100 ml·min);t=15.978,P=0.000]. At CCTA,93.9% (308/328) of the coronary segments had diagnostic image quality. With CCA as the reference standard,the per-vessel and per-segment sensitivity,specificity,and accuracy of CCTA for stenosis≥50% were 94.1%,93.5%,and 93.7% and 90.9%,97.8%,and 96.8%,and the per-vessel sensitivity,specificity and accuracy of ATP stress MPI for stenosis≥50% and ≥70% were 68.7%,100%,and 89.5% and 91.7%,100%,and 97.9%. The total ED of MPI and CCTA was (3.9±1.3) mSv [MPI:(3.5±1.2) mSv,CCTA:(0.3±0.1) mSv]. Conclusion The third-generation DSCT stress dynamic MPI at 70 kV combined with prospectively ECG-triggered high-pitch CCTA is a feasible and reliable tool for clinical diagnosis,with remarkably reduced radiation dose.
Computed Tomography Angiography
;
methods
;
Coronary Artery Disease
;
diagnostic imaging
;
Heart
;
diagnostic imaging
;
Humans
;
Myocardial Perfusion Imaging
;
Prospective Studies
;
Radiation Dosage
;
Sensitivity and Specificity
10.Study on the Taste-masking Effects of Cyclodextrins on Lanqin Extract
Yong XU ; Haiqing YANG ; Yining KONG ; Xiating PING ; Hui LI ; Houhong HE ; Jianbiao YAO
Chinese Journal of Modern Applied Pharmacy 2024;41(2):228-235
OBJECTIVE
To prepare Lanqin extract/cyclodextrin complexes for probing its effects of different kinds of cyclodextrins on the taste-masking.
METHODS
Bitter compounds in the extracts were performed on ion exchange resin adsorption combined with HPLC. The formulations of complexes were screened by human taste panel method. The complexes were prepared by spray-drying and characterized through scanning electron microscope, differential scanning calorimetry, and hygroscopicty test. Moreover, the in vitro bitter taste perception of complexes was evaluated by electronic tongue and further valuation the credibility of the results was conducted on human gustatory sensation tests.
RESULTS
The sulfobutylether-β-cyclodextrin-based combinational formulation with multiple cyclodextrins could significantly inhibit the bitter taste of the extract which mainly caused by its alkaline constituents at a lower dosage. The results of electron scanning microscopy, differential scanning calorimetry, and hygroscopicity indicated that the Lanqin extract and cyclodextrin in the complex may form inclusion complexes rather than physical mixtures. The results of electronic tongue and human gustatory sensation tests showed that, compared with the extract suggested the taste characteristics of the optimal complexes was similar to corresponding excipient while the bitterness significantly reduced.
CONCLUSION
The Lanqin extract/cyclodextrin complexes prepared in this study are suitable for industrial production for its good flavour, less total amount of cyclodextrins, and simple process. The present study has important significance for the development of related taste masking products of Lanqin.