1.Effect of patient decision aids on choice between sugammadex and neostigmine in surgeries under general anesthesia: a multicenter randomized controlled trial
Li-Kai WANG ; Yao-Tsung LIN ; Jui-Tai CHEN ; Winnie LAN ; Kuo-Chuan HUNG ; Jen-Yin CHEN ; Kuei-Jung LIU ; Yu-Chun YEN ; Yun-Yun CHOU ; Yih-Giun CHERNG ; Ka-Wai TAM
Korean Journal of Anesthesiology 2023;76(4):280-289
Background:
Shared decision making using patient decision aids (PtDAs) was established over a decade ago, but few studies have evaluated its efficacy in Asian countries. We therefore evaluated the application of PtDAs in a decision conflict between two muscle relaxant reversal agents, neostigmine and sugammadex, and sequentially analyzed the regional differences and operating room turnover rates.
Methods:
This multicenter, outcome-assessor-blind, randomized controlled trial included 3,132 surgical patients from two medical centers admitted between March 2020 and August 2020. The patients were randomly divided into the classical and PtDA groups for pre-anesthesia consultations. Their clinicodemographic characteristics were analyzed to identify variables influencing the choice of reversal agent. On the day of the pre-anesthesia consultation, the patients completed the four SURE scale (sure of myself, understand information, risk-benefit ratio, encouragement) screening items. The operating turnover rates were also evaluated using anesthesia records.
Results:
Compared with the classical group, the PtDA group felt more confident about receiving sufficient medical information (P < 0.001), felt better informed about the advantages and disadvantages of the medications (P < 0.001), exhibited a superior understanding of the benefits and risks of their options (P < 0.001), and felt surer about their choice (P < 0.001). Moreover, the PtDA group had a significantly greater tendency to choose sugammadex over neostigmine (P < 0.001).
Conclusions
PtDA interventions in pre-anesthesia consultations provided surgical patients with clear knowledge and better support. PtDAs should be made available in other medical fields to enhance shared clinical decision-making.
2.Structural, densitometric and biomechanical evaluations of Chinese patients with long-term bisphosphonate treatment
Kwok-Sui LEUNG ; Ning TANG ; Griffith JAMES ; Tak-Kee CHOY ; Wing-Yin Vivian HUNG ; Hoi-Wa MOK ; Lin SHI
Chinese Medical Journal 2013;(1):27-33
Background The association of long-term bisphosphonate treatment for osteoporosis and related safety problems such as atypical fractures were not clearly defined.This study was to evaluate the structural,densitometric and biomechanical properties of the prolonged bisphosphonate-loaded bones.Methods Bone mineral density (BMD) at hip and femoral midshaft,bone cross-sectional area,moment of inertia of both femurs,bone formation and resorption biochemical markers were compared between 28 elderly with at least 4 years of bisphosphonate treatment from 2002 through 2006 and age-matched group of 37 elderly.Results The total hip BMD and t-score were found not different between two groups.However,bisphosphonate treated patients were found to have significantly lower bone mineral content in the femoral shaft (P <0.05); morphological study showed lower cross-sectional area in subtrochanteric and mid-diaphyseal region and thus significantly lower moment of inertia (P <0.01).High resolution-peripheral quantitative computed tomography showed significantly decreased trabecular density,bone volume ratio,trabecular number but increased trabecular spacing in tibia and distal radius.Finite element analysis further confirmed significantly lower stiffness and failure load in tibia.Biochemical studies also showed lower bone resorption and severely suppressed bone formation activity (P <0.001).Conclusions The unchanged total hip BMD between two groups confirmed the beneficial effects of bisphosphonate on trabecular bone,thus preventing osteoporotic fractures at large in previous studies.However,the inferior structural,densitometric and biomechanical properties at cortical bones,especially femur midshaft,need a special attention to look into the association between long-term bisphosphonate intake and the occurrence of stress fractures.When patients taking bisphosphonate complain of proximal thigh pain or discomfort,plain X-ray film can be the first line screening.All patients prescribed with bisphosphonate should be informed of such a complication though we must stress its rarity.
3.Clinical Characteristics, Genetic Features, and Long-Term Outcome of Wilson’s Disease in a Taiwanese Population: An 11-Year Follow-Up Study
Sung-Pin FAN ; Yih-Chih KUO ; Ni-Chung LEE ; Yin-Hsiu CHIEN ; Wuh-Liang HWU ; Yu-Hsuan HUANG ; Han-I LIN ; Tai-Chung TSENG ; Tung-Hung SU ; Shiou-Ru TZENG ; Chien-Ting HSU ; Huey-Ling CHEN ; Chin-Hsien LIN ; Yen-Hsuan NI
Journal of Movement Disorders 2023;16(2):168-179
Objective:
aaWilson’s disease (WD) is a rare genetic disorder of copper metabolism, and longitudinal follow-up studies are limited. We performed a retrospective analysis to determine the clinical characteristics and long-term outcomes in a large WD cohort.
Methods:
aaMedical records of WD patients diagnosed from 2006–2021 at National Taiwan University Hospital were retrospectively evaluated for clinical presentations, neuroimages, genetic information, and follow-up outcomes.
Results:
aaThe present study enrolled 123 WD patients (mean follow-up: 11.12 ± 7.41 years), including 74 patients (60.2%) with hepatic features and 49 patients (39.8%) with predominantly neuropsychiatric symptoms. Compared to the hepatic group, the neuropsychiatric group exhibited more Kayser-Fleischer rings (77.6% vs. 41.9%, p < 0.01), lower serum ceruloplasmin levels (4.9 ± 3.9 vs. 6.3 ± 3.9 mg/dL, p < 0.01), smaller total brain and subcortical gray matter volumes (p < 0.0001), and worse functional outcomes during follow-up (p = 0.0003). Among patients with available DNA samples (n = 59), the most common mutations were p.R778L (allelic frequency of 22.03%) followed by p.P992L (11.86%) and p.T935M (9.32%). Patients with at least one allele of p.R778L had a younger onset age (p = 0.04), lower ceruloplasmin levels (p < 0.01), lower serum copper levels (p = 0.03), higher percentage of the hepatic form (p = 0.03), and a better functional outcome during follow-up (p = 0.0012) compared to patients with other genetic variations.
Conclusion
aaThe distinct clinical characteristics and long-term outcomes of patients in our cohort support the ethnic differences regarding the mutational spectrum and clinical presentations in WD.
4.Structural, densitometric and biomechanical evaluations of Chinese patients with long-term bisphosphonate treatment.
Kwok-sui LEUNG ; Ning TANG ; James GRIFFITH ; Tak-Kee CHOY ; Vivian Wing-Yin HUNG ; Hoi-Wa MOK ; Lin SHI ; Ping-Chung LEUNG ; Wing-Hoi CHEUNG
Chinese Medical Journal 2013;126(1):27-33
BACKGROUNDThe association of long-term bisphosphonate treatment for osteoporosis and related safety problems such as atypical fractures were not clearly defined. This study was to evaluate the structural, densitometric and biomechanical properties of the prolonged bisphosphonate-loaded bones.
METHODSBone mineral density (BMD) at hip and femoral midshaft, bone cross-sectional area, moment of inertia of both femurs, bone formation and resorption biochemical markers were compared between 28 elderly with at least 4 years of bisphosphonate treatment from 2002 through 2006 and age-matched group of 37 elderly.
RESULTSThe total hip BMD and t-score were found not different between two groups. However, bisphosphonate treated patients were found to have significantly lower bone mineral content in the femoral shaft (P < 0.05); morphological study showed lower cross-sectional area in subtrochanteric and mid-diaphyseal region and thus significantly lower moment of inertia (P < 0.01). High resolution-peripheral quantitative computed tomography showed significantly decreased trabecular density, bone volume ratio, trabecular number but increased trabecular spacing in tibia and distal radius. Finite element analysis further confirmed significantly lower stiffness and failure load in tibia. Biochemical studies also showed lower bone resorption and severely suppressed bone formation activity (P < 0.001).
CONCLUSIONSThe unchanged total hip BMD between two groups confirmed the beneficial effects of bisphosphonate on trabecular bone, thus preventing osteoporotic fractures at large in previous studies. However, the inferior structural, densitometric and biomechanical properties at cortical bones, especially femur midshaft, need a special attention to look into the association between long-term bisphosphonate intake and the occurrence of stress fractures. When patients taking bisphosphonate complain of proximal thigh pain or discomfort, plain X-ray film can be the first line screening. All patients prescribed with bisphosphonate should be informed of such a complication though we must stress its rarity.
Aged ; Aged, 80 and over ; Biomechanical Phenomena ; Bone Density ; drug effects ; Bone Density Conservation Agents ; adverse effects ; Bone Remodeling ; drug effects ; Densitometry ; Diphosphonates ; adverse effects ; Female ; Finite Element Analysis ; Humans ; Male ; Middle Aged ; RANK Ligand ; blood
5.Scaling up the in-hospital hepatitis C virus care cascade in Taiwan
Chung-Feng HUANG ; Pey-Fang WU ; Ming-Lun YEH ; Ching-I HUANG ; Po-Cheng LIANG ; Cheng-Ting HSU ; Po-Yao HSU ; Hung-Yin LIU ; Ying-Chou HUANG ; Zu-Yau LIN ; Shinn-Cherng CHEN ; Jee-Fu HUANG ; Chia-Yen DAI ; Wan-Long CHUANG ; Ming-Lung YU
Clinical and Molecular Hepatology 2021;27(1):136-143
Background/Aims:
Obstacles exist in facilitating hepatitis C virus (HCV) care cascade. To increase timely and accurate diagnosis, disease awareness and accessibility, in-hospital HCV reflex testing followed by automatic appointments and a late call-back strategy (R.N.A. model) was applied. We aimed to compare the HCV treatment rate of patients treated with this strategy compared to those without.
Methods:
One hundred and twenty-five anti-HCV seropositive patients who adopted the R.N.A. model in 2020 and another 1,396 controls treated in 2019 were enrolled to compare the gaps in accurate HCV RNA diagnosis to final treatment allocation.
Results:
The HCV RNA testing rate was significantly higher in patients who received reflex testing than in those without reflex testing (100% vs. 84.8%, P<0.001). When patients were stratified according to the referring outpatient department, a significant improvement in the HCV RNA testing rate was particularly noted in patients from non-hepatology departments (100% vs. 23.3%, P<0.001). The treatment rate in HCV RNA seropositive patients was 83% (83/100) after the adoption of the R.N.A. model, among whom 96.1% and 73.9% of patients were from the hepatology and non-hepatology departments, respectively. Compared to subjects without R.N.A. model application, a significant improvement in the treatment rate was observed for patients from non-hepatology departments (73.9% vs. 27.8%, P=0.001). The application of the R.N.A. model significantly increased the in-hospital HCV treatment uptake from 6.4% to 73.9% for patients from non-hepatology departments (P<0.001).
Conclusions
The care cascade increased the treatment uptake and set up a model for enhancing in-hospital HCV elimination.
6.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
7.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
8.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
9.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
10.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.