1.Clinical Observation on Effect of Qinghua Granules on Glycometabolism, Pancreatic Islet Function and Oxidative Stress in Type-2 Diabetics with Heat Syndrome
Yunhua ZHU ; Feng TAO ; Xin JIN ; Wenqing WANG ; Yimeng GU ; Xuerong YANG ; Hao LU ; Yuandong SHEN
World Science and Technology-Modernization of Traditional Chinese Medicine 2013;(4):753-759
This study was aimed to evaluate effect of Qinghua Granules (QHG) on glycometabolism, pancreatic islet function and oxidative stress in type-2 diabetics with heat syndrome. A total of 60 cases of type-2 diabetics with heat syndrome (according to the Syndrome Element Syndrome Differentiation) were enrolled in the clinic of the Department of Endocrinology and Metabolism, Shuguang Hospital Affiliated to Shanghai University of Tradi-tional Chinese Medicine. The average age of enrolled cases was (57.9 ± 6.9) years. Enrolled cases were randomly divided into the treatment group and the control group. The original hypoglycemic plan was continued to use. In the treatment group, QHG was administrated. And in the control group, placebo was given. The administration dosage in both groups was one package per day. The treatment course was 12 weeks. The fasting and postpran-dial (120 min after standard meal) blood samples before and after medication were collected. The main evalua-tion indexes were fasting plasma glucose (FPG), postprandial plasma glucose (PPG) and hemoglobin A1c (HbA1c). The secondary evaluation indexes were homeostasis model assessment (HOMA2-%B, HOMA2-%S, HOMA2%-IR), superoxide dismutase (SOD), glutathione peroxidase (GSH-PX), maleic dialdehyde (MDA), total cholesterol (TC), triglyceride (TG), high-density lipoprotein (HDL) and low-density lipoprotein (LDL). The anal-ysis of variance was used in the comparison of efficacy between two groups . The results showed that HbA1c in the treatment group was obviously reduced, and HOMA2-%B was obviously increased. There was no significant changes in the control group ( P = 0 . 044 , P = 0 . 016 ) . In the treatment group , SOD increased obviously , MDA reduced obviously. There was no significant change in the control group. There was difference b etween two groups (P = 0.011, P = 0.049). There was no change on blood lipids or other evaluation indexes. It was conclud-ed that QHG is effective in the improvement of glycometabolism, islet β-cell functions and oxidative stress in type-2 diabetics with heat syndrome .
2. Application of three-dimensional printing personalized acetabular wing-plate in treatment of complex acetabular fractures via lateral-rectus approach
Qiguang MAI ; Cheng GU ; Xuezhi LIN ; Tao LI ; Weiqi HUANG ; Hua WANG ; Xinyu TAN ; Hui LIN ; Yimeng WANG ; Yongqiang YANG ; Dadi JIN ; Shicai FAN
Chinese Journal of Surgery 2017;55(3):172-178
Objective:
To investigate reduction and fixation of complex acetabular fractures using three-dimensional (3D) printing technique and personalized acetabular wing-plate via lateral-rectus approach.
Methods:
From March to July 2016, 8 patients with complex acetabular fractures were surgically managed through 3D printing personalized acetabular wing-plate via lateral-rectus approach at Department of Orthopedics, the Third Affiliated Hospital of Southern Medical University. There were 4 male patients and 4 female patients, with an average age of 57 years (ranging from 31 to 76 years). According to Letournel-Judet classification, there were 2 anterior+ posterior hemitransverse fractures and 6 both-column fractures, without posterior wall fracture or contralateral pelvic fracture. The CT data files of acetabular fracture were imported into the computer and 3D printing technique was used to print the fractures models after reduction by digital orthopedic technique. The acetabular wing-plate was designed and printed with titanium. All fractures were treated via the lateral-rectus approach in a horizontal position after general anesthesia. The anterior column and the quadrilateral surface fractures were fixed by 3D printing personalized acetabular wing-plate, and the posterior column fractures were reduction and fixed by antegrade lag screws under direct vision.
Results:
All the 8 cases underwent the operation successfully. Postoperative X-ray and CT examination showed excellent or good reduction of anterior and posterior column, without any operation complications. Only 1 case with 75 years old was found screw loosening in the pubic bone with osteoporosis after 1 month′s follow-up, who didn′t accept any treatment because the patient didn′t feel discomfort. According to the Matta radiological evaluation, the reduction of the acetabular fracture was rated as excellent in 3 cases, good in 4 cases and fair in 1 case. All patients were followed up for 3 to 6 months and all patients had achieved bone union. According to the modified Merle D′Aubigné and Postel scoring system, 5 cases were excellent, 2 cases were good, 1 case was fair.
Conclusions
Surgical management of complex acetabular fracture via lateral-rectus approach combine with 3D printing personalized acetabular wing-plate can effectively improve reduction quality and fixation effect. It will be truly accurate, personalized and minimally invasive.
3.Prenatal MRI diagnosis and postnatal outcomes of fetal intracranial hemorrhage: analysis of 49 cases
Shulei CAI ; Guofu ZHANG ; Xiaoliang MA ; Qing ZHOU ; Yimeng HE ; Qianyu GU ; Xirong XIAO ; He ZHANG
Chinese Journal of Perinatal Medicine 2020;23(11):742-749
Objective:To investigate the prenatal MRI diagnosis of fetal intracranial hemorrhage (ICH) and the pregnancy outcomes.Methods:This retrospective study included 49 cases of fetal ICH diagnosed by MRI in Obstetrics and Gynecology Hospital of Fudan University from July 2011 to November 2019. Two experts with more than five years of experience in obstetric radiology determined the location, number, area, stage and grade of the hemorrhage based on the MRI findings. Maternal age, gestational age at MRI, and the site, number, stage and grade of hemorrhage as well as other intracranial and extracranial abnormalities of the fetuses were compared between women with fetal germinal matrix-intraventricular hemorrhage (GM-IVH; GM-IVH group, n=39) and those without (non-GM-IVH group, n=10). MRI and ultrasound examination results of 37 cases who had MRI within three days after the ultrasound examination were compared. Postnatal and follow-up outcomes were summarized. Statistical analysis was performed using the independent sample t-test, Mann-Whitney U test and Chi-square test. Results:There was no significant difference in the maternal age, gestational age at MRI, or the site, number or stage of hemorrhage between the GM-IVH group and non-GM-IVH group (all P>0.05). The incidence of ventriculomegaly was higher in the GM-IVH group than that in the non-GM-IVH group [87% (34/39) vs 0/10, t=24.522, P<0.001]. There were 51% (19/37) of the lesions that were missed by ultrasound found by MRI, including GM-IVH in 17 cases, right cerebellar hemisphere hemorrhage in one case and corpus callosum hemorrhage in one case. Among the 49 cases, seven were lost to follow-up, 29 terminated the pregnancy (six in non-GM-IVH group and 23 in GM-IVH group), two experienced intrauterine fetal death in late pregnancy and 11 gave live birth. Ten live births had GM-IVH, among them a relatively good prognosis was noted in fetuses with grade Ⅰ (two cases), grade Ⅱ (four cases), and grade Ⅲ (three cases) GM-IVH, while one case with grade Ⅳ GM-IVH had mental retardation at eight years old; one non-GM-IVH infant had hearing loss at birth and a cochlear was implanted with no other anomalies reported during a three-year follow-up. Conclusions:MRI can provide a more direct view of the location and grade of fetal ICH and is more accurate than prenatal ultrasound in diagnosing fetal ICH, which is a beneficial supplement to ultrasound. The prognosis of cases with grade Ⅳ GM-IVH is not good.
4.Accuracy of progress assessment with clear aligners.
Bo LI ; Yimeng XU ; Ruiying SHI ; Yirong HU ; Siying LIU ; Zexu GU
West China Journal of Stomatology 2022;40(6):698-703
OBJECTIVES:
This study aimed to investigate the accuracy of model superimposition and automatic analysis for upper and lower dentition widths in iTero Progress Assessment during the clear aligner process.
METHODS:
Nineteen cases were included in this retrospective case control study. Pretreatment dental cast (T0) and post treatment dental cast after staged treatment (T1) were available for three-dimensional (3D) model superimposition. The movements of maxillary teeth in the horizontal plane (cross section) after staged treatment and the widths of upper and lower dentitions were measured by 3D model superimposition in real world and iTero Progress Assessment. The data collected from the two methods were compared.
RESULTS:
The movements [Median (upper and lower quartiles)] of maxillary teeth in the horizontal plane after staged treatment were 2.31 (1.59, 3.22) and 1.79 (1.21, 3.03) mm in iTero Progress Assessment and 3D model analysis, respectively. Significant difference was observed between the two groups (P<0.05). In the measurement of upper and lower dentition width, four indicators were measured, including intercanine width upper, intermolar width upper, intercanine width lower, and intermolar width lower. Before treatment, the measurement of iTero Progress Assessment were (35.78±2.49), (56.21±2.51), (27.43±1.38), (52.26±2.91) mm, respectively, and actual measurement were (35.77±2.53), (56.17±2.47), (27.40±1.41), (52.30±2.86) mm, respectively, without significant difference (P>0.05). After stage treatment, the measurement of iTero Progress Assessment were (37.37±2.86), (57.76±2.56), (28.89±2.00), (54.16±2.19) mm, respectively, and actual measurement were (37.29±2.94), (57.71±2.63), (28.88±2.05), (54.01±2.15) mm, respectively, and there was no significant difference (P>0.05).
CONCLUSIONS
The data from iTero Progress Assessment did not coincide with the model superimposition results with palate as reference. The accuracy of model superimposition in iTero Progress Assessment needs further investigation, whereas the arch width analysis is accurate. Therefore, iTero Progress Assessment results should be interpreted with caution by orthodontists in clinical applications.
Case-Control Studies
;
Cuspid
;
Dental Arch
;
Orthodontic Appliances, Removable
;
Retrospective Studies
;
Humans