Objective: To develop a method for determination of chlorgenic acid in Shuangyin Solution.Methods: HPLC with Hypersil-ODS column (4.6?250mm,5?m) was used. The mobile phase was acetonitrile-water-acetic acid glacial (10∶110∶3). The detective wavelength was 328nm.Results: The linear range was from 0.0568 ~0.2840mg/mL. The average recovery was 100.16%.Conclusion: The method is simple, rapid and accurate. It can be used to determine chlorgenic acid in Shuangyin Solution.