1.Clinical Characteristics and Early Risk Factors for Toxic Encephalopathy in Acute Diquat Poisoning
Yihong YANG ; Jiawei LI ; Xiaojuan LIU ; Qiqi LIU ; Hongbo LIU ; Guanghua XIONG ; Yecheng LIU
Medical Journal of Peking Union Medical College Hospital 2025;16(5):1229-1235
To analyze the clinical characteristics of acute diquat poisoning complicated by central nervous system injury (CNSI) and identify early risk factors, aiming to provide a theoretical basis for reducing mortality in diquat poisoning with CNSI. Clinical data from patients with acute diquat poisoning admitted to the Emergency Department of Fuyang People's Hospital Affiliated to Anhui Medical University between October 2019 and October 2024 were retrospectively analyzed. Patients were divided into CNSI and non-CNSI groups based on complications. Clinical features were compared between groups, and variables with statistical significance were subjected to binary logistic regression to identify independent risk factors for CNSI. Receiver operating characteristic (ROC) curves were generated to evaluate the predictive value of these factors. A total of 63 eligible patients were included, with 18 deaths (28.57%) and 26 cases (41.27%) complicated by CNSI. The median time from diquat ingestion to CNSI onset was 15.5 (9.8, 31.3) hours. The CNSI group exhibited significantly higher mortality rates and required more frequent respiratory support and anti-shock therapy than the non-CNSI group (all CNSI is a fatal complication of acute diquat poisoning with high mortality. Diquat plasma concentration (≥549.95 μg/L) and APACHE Ⅱ score are independent risk factors for CNSI, and their combined application enhances predictive accuracy. These findings underscore the importance of early risk stratification and targeted interventions in high-risk populations.
2.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
3.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
4.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
5.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
6.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
7.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
8.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
9.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
10.Risk Factors of Capillary Leak Syndrome in Patients with Acute Organophosphorus Pesticide Poisoning
Xu HAN ; Yihong YANG ; Hui JIANG ; Yecheng LIU
Medical Journal of Peking Union Medical College Hospital 2024;15(4):855-861
To explore the risk factors of capillary leakage syndrome in patients with acute organophosphorus pesticide poisoning (AOPP), in order to provide reference for clinical screening and intervention timing. The clinical manifestations, auxiliary examination and prognosis of AOPP patients admitted in Fuyang People's Hospital from November 2020 to June 2022 were prospectively analyzed, and the patients were divided into non-CLS group and CLS group based on the presence or absence of capillary leak syndrome (CLS). Patients were admitted to hospital as the starting point, and death or discharge as the endpoint. Multiple Logistic regression analysis was used to explore the risk factors of AOPP complicated with CLS. A total of 38 AOPP patients were included, of which 17 (44.7%) were complicated with CLS. There were statistical differences in age ( Patients with AOPP are more likely to be complicated by CLS, and the mortality rate is higher. High-risk patients can be identified early by dipterex blood concentration and APACHE Ⅱ score, and early intervention can be carried out to improve the prognosis of patients.

Result Analysis
Print
Save
E-mail