1.Development of a Loop-Mediated Isothermal Amplification Assay for Porcine Circovirus Type 2
Yebing LIU ; Lei ZHANG ; Qinhong XUE ; Yibao NING ; Zhigang ZHANG
Virologica Sinica 2011;26(3):214-220
In this study,the loop-mediated isothermal amplification(LAMP)method was used to develop a rapid and simple detection system for porcine circovirus type 2(PCV2).According to the PCV2 sequences published in GenBank,multiple LAMP primers were designed targeting conserved sequences of PCV2.Using the DNA extracted from PCV2 isolates HUN-09 and SD-09 as the template,LAMP reactions in a PCV2 LAMP system was performed,the amplification products were detected by adding SYBR Green I and could be observed directly by the naked eye.The results showed highly-efficient and specific amplification in 30 min at 63℃ with a LAMP real-time turbidimeter.Furthermore,PCV2 DNA templates,with a detection limit of 5.5×10-5ng of nucleic acid,indicated that this assay was highly sensitive.The results obtained with the naked eye after SYBR Green I staining were consistent with those detected by the real-time turbidimeter,showing the potential simplicity of interpretation of the assay results.The LAMP assay appeared to have greater accuracy than PCR and virus isolation for the analysis of 18 clinical samples.In addition it offers higher specificity and sensitivity,shorter reaction times and simpler procedures than the currently available methods of PCV2 detection.It is therefore a promising tool for the effective and efficient detection of PCV2.
2.Rapid and Sensitive Detection of PRRSV by a Reverse Transcription-Loop-mediated Isothermal Amplification Assay
Lei ZHANG ; Yebing LIU ; Lei CHEN ; Jianhuan WANG ; Yibao NING
Virologica Sinica 2011;26(4):252-259
A real-time monitoring reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the sensitive and specific detection of prototypic,prevalent North American porcine reproductive and respiratory syndrome virus (PRRSV)strains.As a higher sensitivity and specificity method than reverse transcription polymerase chain reaction (RT-PCR),the RT-LAMP method only used a turbidimeter,exhibited a detection limit corresponding to a 10-4 dilution of template RNA extracted from 250 μL of 105 of the 50% tissue culture infective dose (TCID50) of PRRSV containing cells,and no cross-reactivity was observed with other related viruses including porcine circovirus type 2,swine influenza virus,porcine rotavirus and classical swine fever virus.From forty-two field samples,33 samples in the RT-LAMP assay was detected positive,whereas three of which were not detected by RT-PCR.Furthermore,in 33 strains of PRRSV,an identical detection rate was observed with the RT-LAMP assay to what were isolated using porcine alveolar macrophages.These findings demonstrated that the RT-LAMP assay has potential clinical applications for the detection of highly pathogenic PRRSV isolates,especially in developing countries.